• 제목/요약/키워드: Metalic contamination

검색결과 4건 처리시간 0.021초

$Na^{131}I$에 의(依)한 오염도(汚染度) 및 오염제거(汚染除去)의 실험적(實驗的) 연구(硏究) (An Experimental Study on Airborne Contamination and Decontamination for $Na^{131}I$ Solution)

  • 추성실;박창윤
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.112-117
    • /
    • 1984
  • A lot of radioisotopes are applied to medical fields. It's very important to measure the activities on airborne radioiodine discharged in air from $Na^{131}I$ solutions and from patients treated with radioiodine. Also surface decontamination is another one important problem to be completly solved in the isotope laboratory where there is always the possibility of radiation contamination. The Authors measured the activities on airborne radioiodine with RI collector and scintillation counter. 1. The mean accumulative activity of airborne radioiodine discharged into air from $Na^{131}I$ solution was measured as $1.3{\times}10^{-3}/hr$ rate, and the maximum value was $1.8{\times}10^{-3}/hr$. 2. Radioactivity rate per hour of airborne iodine discharged into air from patients treated with $Na^{131}I$ was measured as $6.2{\times}10^{-5}/hr$ at 8 hour after administration of radioiodine and decreased into $2{\times}10^{-6}/hr$ after 24 hour. 3. Metalic surfaces such as stainless steel or aluminum are decontaminated 5 to 6 times more rapidly than wood and concrete surfaces. 4. Decontamination with wet wiping with detergent was 9 to 10 times more rapidly than dry wiping method, but dry wiping was useful for the first step to prevent spreading and flowing from liquid radioactive materials.

  • PDF

BTS 측정 분석을 통한 MLCC 소자의 결함 여부 판단

  • 최평호;김상섭;최병덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.298-298
    • /
    • 2012
  • 본 연구에서는 Bias Temperature Stress (BTS) 측정을 통한 다층세라믹커패시터(Multi-Layer Ceramic Capacitor, MLCC) 소자 분석에 대한 연구를 진행하였다. BTS 분석은 소자 내부에 존재하는 Na+, K+ 등의 mobile charge 검출을 위한 방법으로 positive bias와 negative bias stress에 따른 C-V 특성 곡선으로부터 mobile charge의 정량적 해석이 가능하다. 실험 결과 positive bias stress 후의 C-V 특성 곡선이 stress 전 C-V 특성 곡선과 비교해 negative bias 영역으로 0.0376 V 만큼 shift 하였다. 또한 수식(QM = $Cox{\cdot}{\triangle}V$)으로부터 $1.7{\times}1,011$개의 mobile charge가 존재함을 확인하였다. 본 연구는 MLCC 소자 내의 금속 오염물 존재 여부에 따른 소자의 전기적 특성 변화 분석을 위해 진행되었으며, BTS 분석은 반도체 소자 뿐 아니라 본 연구에서와 같이 커패시터 소자의 결함 여부 판단에도 이용 가능함을 확인하였다.

  • PDF

유류저장시설로 인한 토양오염 예방대책 (Prevention of Soil Contamination from Underground Storage Facilities)

  • 배우근;홍종철;정진욱;강우재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.169-173
    • /
    • 1998
  • The practice of the construction and management of the underground petroleum storage facilities in Korea was investigated extensively, and the problems were identified. The advanced technologies in the U.S.A was comparatively studied. Considering the effectiveness of leak prevention and technology applicability, the following measures were suggested. To prevent corrosion of the tank, a clad tank, an interior-lining tank, or a double-wall tank was appropriate and appeared to be most cost effective. For piping, non-metalic material was suggested. To prevent spill, a catchment basin can be effective. For monitoring of leak, construction of more than one of one or combination of an automatic leak-detection device, a vapor-detection system, a ground water-monitoring system, and a double-wall detection system was recommended.

  • PDF

유류 및 유해화학물질 저장시설에서의 토양오염 방지대책 (Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds)

  • 배우근;홍종철;정진욱;김종호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권4호
    • /
    • pp.40-47
    • /
    • 2002
  • 본 연구는 유류저장시설에서의 토양오염 방지를 위한 국·내외 관련 시설과 기술 조사 및 관련 법규정 검토를 통해 국내 시설의 현황과 문제점을 도출하고 토양오염 방지조치시설의 기준을 구체화하거나 보완 또는 개선하여 보다 효과적인 토양오염 방지책을 제시하고자 하였다. 부식산화 방지를 위해 저장탱크는 강철-클래드 탱크, 내부 라이닝 탱크 또는 이중벽 탱크를 사용하고 배관은 내부식성 물질로 만든 배관을 사용하는 것이 비용경제적이며 효율적이라고 사료된다. 흘림방지를 위해 주유기 Sump를 설치할 필요가 있으며, 넘침방지 시설의 보호를 위해 유류의 주입방식을 가압식 주입에서 자연 유하식 주입으로 변경할 필요가 있다. 모든 탱크 및 배관 관련 시설은 저장물질의 누출여부를 확인할 수 있도록 자동누출측정기기, 증기 감지시설, 지하수 감시시설, 또는 이중벽 감시시설 등 저장물질의 누출여부를 확인할 수 있도록 한가지 이상의 모니터링 시설을 갖추어야 할 필요가 있는 것으로 나타났다.