• 제목/요약/키워드: Metal shielding

검색결과 236건 처리시간 0.042초

Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구 (A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal)

  • 장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

금속 용사 피막의 전기전도도 및 전자파 차폐 특성에 관한 연구 (A Study on the Electrical Conductivity and Electromagnetic Pulse Shielding Characteristics of Metal Sprayed Coating)

  • 장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2020
  • In this study, the electrical conductivity and shielding effect were evaluated according to the type of metal and the thickness of Metal sprayed coating. The metals used for the test are Cu, Cu-Ni and Cu-Zn, and the thicknesses were 100, 200, 500 um. Each metal sprayed coating was evaluated for electrical conductivity and electromagnetic shielding effect. When the thickness was 200 ㎛ or more, shielding effect 80 dB or more was satisfied at 1 GHz. However, in the case of Cu-Ni, there is little electrical conductivity at a thickness of 100 um or less due to the generated voids, and electromagnetic wave shielding performance cannot be expected. Therefore, To ensure electromagnetic shielding effect of structures, it is considered that the minimum thickness of metal spraying coating should be 200 um.

  • PDF

Zn-Al 아크 금속용사 피막을 적용한 구리분말 혼입 시멘트 모르타르의 전자파 차폐 성능 평가 (The Shielding Effectiveness of Zn-Al Arc Thermal Metal Film Coated Cement-Mortar Using Copper Powder)

  • 최현준;최현국;김형철;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.124-125
    • /
    • 2017
  • In this study, the shielding effectiveness of the Zn-Al arc thermal metal film coated cement-mortar mixed with copper powder by reflection, absorption, multi-reflection loss in 2.25~2.65 GHz was reviewed. By enhancing the mixing ratio of copper powder, the shielding effectiveness by absorption and multi-reflection loss was increased, but shielding rate(%) based on 80 dB showed below 20%. The Zn-Al arc thermal metal film coated on specimen, the shielding rate increased 3.5 times by reflection loss.

  • PDF

PVD법을 이용한 전자파 차폐용 시트 제조 및 차폐효율 특성 (Preparation of EMI Shielding Sheet by PVD Method and Its Characteristic of EMI Shielding Efficiency)

  • 채성정;홍병표;이병수;변홍식
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.527-531
    • /
    • 2010
  • Fe계 metal powder를 이용하여 최적화된 전자파차폐 시트를 제조한 후, 제조된 시트에 physical vapor deposition (PVD)법으로 여러 금속들을 증착시켜 최종 전자파차폐용 시트를 제조하였다. 또한 증착된 금속들의 전자파 효율 특성을 분석하기 위하여 polyvinylidene fluoride (PVdF) 나노섬유 막을 시트로 활용하였다. 전기적 특성을 알아보기 위해 4-point probe로 측정하였으며, energy dispersive spectroscopy (EDS)를 이용하여 제조된 sheet에 금속이 증착되었음을 확인하였다. 차폐효율은 전자파차폐효율측정기를 이용하여 측정하였다. 전기저항은 $1000\;{\AA}$일 때 Cu에서 $641.95{\Omega}{\cdot}cm$로 가장 낮은 저항 값을 나타내었다. 전자파 차폐효율은 증착된 금속의 두께의 증가에 따라 증가되었으며, Cu가 $1000\;{\AA}$으로 증착된 sheet가 최고 효율인 32.5 dB을 나타내었다.

니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구 (Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect)

  • 서광수;곽이구
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • 한국건축시공학회지
    • /
    • 제13권1호
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

노이즈 소스 근거리장에 위치한 금속 차폐막의 차폐효과 분석 (Analysis for Shielding Effectiveness of Metal Shielding Layer within Near-Field of Noise Source)

  • 이원선;이원희;허정
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.59-65
    • /
    • 2019
  • 마그네틱 프로브와 노이즈 소스의 근거리장에 금속 차폐막이 놓여있을 때 차폐막 두께에 따른 EMI 차폐효과를 분석하였다. 노이즈 소스로는 마이크로스트립 라인을 이용하였으며, 금속 차폐막 재료로는 그래파이트와 페라이트를 선정하였다. 마그네틱 프로브는 IEC 61967-6 방식을 적용하여 마그네틱 프로브를 이용한 전자기 방사 측정 방법을 사용하였다. 마이크로스트립 라인과 마그네틱 프로브 사이의 투과계수를 분석하였고, 둘 사이의 거리는 단일 차폐막일 경우 1 mm, 다중 차폐막일 경우 5 mm로 수행하였다. 차폐막의 두께는 5 um, 10 um, 30 um, 50 um 으로 변화시켰다. 주파수를 150 kHz에서 1 GHz까지 변화시켰을 경우 최대 44.9 dB의 SE(Shielding Effectiveness)를 얻었다.

콘크리트 표면 처리 방법 및 용사면에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가 (Evaluation of physical properties of Zn-Al metal spray coating according to concrete surface and treatment method)

  • 장종민;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2022
  • When a metal sprayed film of several hundred ㎛ on the concrete surface is possible to 80 dB of shielding effect electromagnetic waves (ElectroMagnetic Pulse, EMP). Therefore, in this study, as a way to secure EMP shielding performance by applying a metal spray coating showing excellent EMP shielding performance to a concrete structure, the metal spray welding efficiency and thin film adhesion performance according to the concrete spray direction and surface treatment method were evaluated. Metal sprayed efficieny according to the metal spraying direction and method was confirmed that the difference was insignificant by applying the roughening agent. However, the method of strengthening the concrete surface and applying the sealing agent show maximum adhesion strength of 3.98 MPa compared to other methods, and it is judged that this method can be utilized for the metal spraying method for concrete EMP shielding.

  • PDF

Cure Characteristics of Metal Particle Filled DGEBA/MDA/SN/ zeolite Composite System for EMI Shielding

  • Cho, Young-Shin;Lee, Hong-Ki;Shim, Mi-Ja;Kim, Sang-Wook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.548-551
    • /
    • 1999
  • The cure characteristics of metal particle filled DGEBA/MDA/SN/ zeolite epoxy resin composite system for EMI shielding were investigated by dynamic DSC run method and FT-lR spectroscopy. As the heating rate increased, the peak temperature on dynamic DSC curve increased because of the rapid cure reaction. From the straight line of the Kissinger plot, the curing reaction activation energy and pre-exponential factor could be obtained. As the post-curing time at 15$0^{\circ}C$ increased, the glass increased the glass transition temperature or the thermal stability increased. When the post curing time is too long, the system filled with metallic Al particle can be thermally oxidized by the catalytic reaction of metal filler and the thermal stability of the composite for the EMI shielding application may be decreased.

  • PDF

보호가스 종류에 따른 고출력 레이저 용접특성 (The Effect of Shielding Gas Composition on High Power Laser Welding Characteristics)

  • 안영남;김철희
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.17-23
    • /
    • 2015
  • Laser-gas metal arc hybrid welding has been considered as an alternative process of gas metal arc welding for offshore pipe laying. Fiber delivered high power lasers which enable deep penetration welding were recently developed but high power welding characteristics were not fully understood yet. In this study, the influence of shielding gas composition on welding phenomena in high power laser welding was investigated. Bead shapes, melt ejection and dropping were observed after autogenous laser welding with 100% Ar, Ar-20% $CO_2$, Ar-50% $CO_2$, and 100% $CO_2$ shielding gas. Process parameter window was widest with Ar-50% $CO_2$ shielding gas and the penetration was deepest with 100% $CO_2$ shielding gas. The melt dropping was not observed when Ar-50% $CO_2$ or 100% $CO_2$ shielding gas was supplied.