• Title/Summary/Keyword: Metal shielding

Search Result 236, Processing Time 0.023 seconds

A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal (Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

A Study on the Electrical Conductivity and Electromagnetic Pulse Shielding Characteristics of Metal Sprayed Coating (금속 용사 피막의 전기전도도 및 전자파 차폐 특성에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.8-9
    • /
    • 2020
  • In this study, the electrical conductivity and shielding effect were evaluated according to the type of metal and the thickness of Metal sprayed coating. The metals used for the test are Cu, Cu-Ni and Cu-Zn, and the thicknesses were 100, 200, 500 um. Each metal sprayed coating was evaluated for electrical conductivity and electromagnetic shielding effect. When the thickness was 200 ㎛ or more, shielding effect 80 dB or more was satisfied at 1 GHz. However, in the case of Cu-Ni, there is little electrical conductivity at a thickness of 100 um or less due to the generated voids, and electromagnetic wave shielding performance cannot be expected. Therefore, To ensure electromagnetic shielding effect of structures, it is considered that the minimum thickness of metal spraying coating should be 200 um.

  • PDF

The Shielding Effectiveness of Zn-Al Arc Thermal Metal Film Coated Cement-Mortar Using Copper Powder (Zn-Al 아크 금속용사 피막을 적용한 구리분말 혼입 시멘트 모르타르의 전자파 차폐 성능 평가)

  • Choi, Hyun-Jun;Choi, Hyun-Kuk;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.124-125
    • /
    • 2017
  • In this study, the shielding effectiveness of the Zn-Al arc thermal metal film coated cement-mortar mixed with copper powder by reflection, absorption, multi-reflection loss in 2.25~2.65 GHz was reviewed. By enhancing the mixing ratio of copper powder, the shielding effectiveness by absorption and multi-reflection loss was increased, but shielding rate(%) based on 80 dB showed below 20%. The Zn-Al arc thermal metal film coated on specimen, the shielding rate increased 3.5 times by reflection loss.

  • PDF

Preparation of EMI Shielding Sheet by PVD Method and Its Characteristic of EMI Shielding Efficiency (PVD법을 이용한 전자파 차폐용 시트 제조 및 차폐효율 특성)

  • Chae, Seong-Jeong;Hong, Byung-Pyo;Lee, Byoung-Soo;Byun, Hong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.527-531
    • /
    • 2010
  • The optimized sheet for EMI shielding was prepared by metal power with Fe series. Then various metal powders were deposited on the sheet by PVD method. Moreover, the PVdF nanofiber membrane was used to compare the characteristic of EMI shielding efficiency of various metal powders. The electrical property was measured by the 4-point probe method. The result from EDS confirmed that the metal powder existed on the sheet. EMI shielding efficiency was analysed by EMI shielding measurement apparatus. The lowest electrical resistance, $641.95{\Omega}{wcdot}cm$, was obtained with $1000\;{\AA}$ deposition of Cu on the sheet. It was revealed that the EMI shielding efficiency increased with increase of the metal deposition thickness. The sheet deposited by Cu with $1000\;{\AA}$ showed the highest EMI shielding efficiency, 32.5 dB.

Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect (니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구)

  • Seo, Kwang-Su;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

Analysis for Shielding Effectiveness of Metal Shielding Layer within Near-Field of Noise Source (노이즈 소스 근거리장에 위치한 금속 차폐막의 차폐효과 분석)

  • Lee, Won-Seon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • The EMI shielding effectiveness of the shielding layer thickness was analyzed when the metal shielding layer was placed in the near field of the magnetic probe and the noise source. Microstrip lines were used as noise source, and graphite and ferrite were selected as metal shielding materials. The magnetic probe uses the electromagnetic radiation measurement method using the magnetic probe by applying the IEC 61967-6 method. The transmission coefficient between the microstrip line and the magnetic probe was analyzed. The distance between the two was 1 mm for a single shielding layer and 5 mm for a multiple shielding layer. The thickness of the shielding layer was changed to 5 um, 10 um, 30 um, and 50 um. When the frequency was changed from 150 kHz to 1 GHz, a maximum shielding effectiveness (SE) of 44.9 dB was obtained.

Evaluation of physical properties of Zn-Al metal spray coating according to concrete surface and treatment method (콘크리트 표면 처리 방법 및 용사면에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Yang, Hyun Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.59-60
    • /
    • 2022
  • When a metal sprayed film of several hundred ㎛ on the concrete surface is possible to 80 dB of shielding effect electromagnetic waves (ElectroMagnetic Pulse, EMP). Therefore, in this study, as a way to secure EMP shielding performance by applying a metal spray coating showing excellent EMP shielding performance to a concrete structure, the metal spray welding efficiency and thin film adhesion performance according to the concrete spray direction and surface treatment method were evaluated. Metal sprayed efficieny according to the metal spraying direction and method was confirmed that the difference was insignificant by applying the roughening agent. However, the method of strengthening the concrete surface and applying the sealing agent show maximum adhesion strength of 3.98 MPa compared to other methods, and it is judged that this method can be utilized for the metal spraying method for concrete EMP shielding.

  • PDF

Cure Characteristics of Metal Particle Filled DGEBA/MDA/SN/ zeolite Composite System for EMI Shielding

  • Cho, Young-Shin;Lee, Hong-Ki;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.548-551
    • /
    • 1999
  • The cure characteristics of metal particle filled DGEBA/MDA/SN/ zeolite epoxy resin composite system for EMI shielding were investigated by dynamic DSC run method and FT-lR spectroscopy. As the heating rate increased, the peak temperature on dynamic DSC curve increased because of the rapid cure reaction. From the straight line of the Kissinger plot, the curing reaction activation energy and pre-exponential factor could be obtained. As the post-curing time at 15$0^{\circ}C$ increased, the glass increased the glass transition temperature or the thermal stability increased. When the post curing time is too long, the system filled with metallic Al particle can be thermally oxidized by the catalytic reaction of metal filler and the thermal stability of the composite for the EMI shielding application may be decreased.

  • PDF

The Effect of Shielding Gas Composition on High Power Laser Welding Characteristics (보호가스 종류에 따른 고출력 레이저 용접특성)

  • Ahn, Young-Nam;Kim, Cheolhee
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.17-23
    • /
    • 2015
  • Laser-gas metal arc hybrid welding has been considered as an alternative process of gas metal arc welding for offshore pipe laying. Fiber delivered high power lasers which enable deep penetration welding were recently developed but high power welding characteristics were not fully understood yet. In this study, the influence of shielding gas composition on welding phenomena in high power laser welding was investigated. Bead shapes, melt ejection and dropping were observed after autogenous laser welding with 100% Ar, Ar-20% $CO_2$, Ar-50% $CO_2$, and 100% $CO_2$ shielding gas. Process parameter window was widest with Ar-50% $CO_2$ shielding gas and the penetration was deepest with 100% $CO_2$ shielding gas. The melt dropping was not observed when Ar-50% $CO_2$ or 100% $CO_2$ shielding gas was supplied.