• Title/Summary/Keyword: Metal point

Search Result 1,070, Processing Time 0.037 seconds

Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV (FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석)

  • Lee, J.M.;Jeong, J.H.;Chon, M.S.;Lee, H.W.
    • Transactions of Materials Processing
    • /
    • v.27 no.1
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

Fabrication and Static Bending Test in Ultra Light Inner Structured and Bonded(ISB) Panel Containing Repeated Inner Pyramidal Structure (피라미드 형상의 내부구조를 가지는 초경량 금속 내부구조 접합판재의 제작 및 정적 굽힘실험)

  • Jung Chang Gyun;Yoon Seok-Joon;Lee Sang Min;Na Suck-Joo;Lee Sang-hoon;Ahn Dong-Gyu;Yang Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.175-182
    • /
    • 2005
  • Inner structured and bonded panel, or ISB Panel, as a kind of sandwich type panel, has metallic inner structures which have low relative density, because of their dimensional shape of metal between a pare of metal skin sheets or face sheets. In this work, ISB panels and inner structures formed as repeated pyramidal shapes are introduced. Pyramidal structures are formed easily with expanded metal sheet by the crimping process. Three kinds of pyramidal structures are made and used to fabricate test specimen. Through the multi-point electrical resistance welding, inner structures are bonded with skin sheet. 3-point bending tests are carried out to measure the bending stiffness of ISB panel and experimental results are discussed.

Composition Analysis and Thermodynamic Care for Replication of Ancient Metallic Type (고대 금속활자의 복제를 위한 성분분석과 열역학적 주의 점)

  • Kim, Ki-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • 'Jikjisimcheyocheal (Jikji afterwards)' is known as a first book printed by the metal type in the world. The metal type used for printing this book has not been found yet. To help for replicating the original metal type, it is required to investigate the composition analysis of the copied metal type. In this study, the composition analysis and thermodynamic care for replicating of ancient metal type was performed on the basis of an analytical reports concerned with the ancient metal type which made after Jikji printing. Metal types were made by remelting and casting of the mother alloy which came from a cast of a mixed metals in accordance with the composition revealed in the literatures. Change of composition during remelting of mother alloy and casting of metal was detected by the EDS analysis. The reasons for variation in composition were discussed by metallurgical and thermodynamic point of view, and a mixing ratio of metals to get the original composition of ancient metal type is suggested. Some attention should be paid on mixing, melting and casting of metals to get an objected composition for copy of ancient metal type.

Controlled Conversion of Sodium Metal From Nuclear Systems to Sodium Chloride

  • Herrmann, Steven;Zhao, Haiyan;Shi, Meng;Patterson, Michael
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.233-241
    • /
    • 2021
  • A series of three bench-scale experiments was performed to investigate the conversion of sodium metal to sodium chloride via reactions with non-metal and metal chlorides. Specifically, batches of molten sodium metal were separately contacted with ammonium chloride and ferrous chloride to form sodium chloride in both cases along with iron in the latter case. Additional ferrous chloride was added to two of the three batches to form low melting point consolidated mixtures of sodium chloride and ferrous chloride, whereas consolidation of a sodium-chloride product was performed in a separate batch. Samples of the products were characterized via X-ray diffraction to identify attendant compounds. The reaction of sodium metal with metered ammonium chloride particulate feeds proceeded without reaction excursions and produced pure colorless sodium chloride. The reaction of sodium metal with ferrous chloride yielded occasional reaction excursions as evidenced by temperature spikes and fuming ferrous chloride, producing a dark salt-metal mixture. This investigation into a method for controlled conversion of sodium metal to sodium chloride is particularly applicable to sodium containing elevated levels of radioactivity-including bond sodium from nuclear fuels-in remote-handled inert-atmosphere environments.

Investigation into characteristics of bending stiffness and failure for ISB panel (ISB 판넬의 굽힘강성 및 파단특성에 관한 연구)

  • 안동규;이상훈;김민수;한길영;정창균;양동열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1274-1277
    • /
    • 2004
  • The objective of this research work is to investigate into characteristics of bending stiffness and failure for the ISB ultra-lightweight panel with internally structured material. The expanded metal with a pyramid shape and woven metal are employed as an internally structured material. In order to investigate the characteristics, the specific stiffness and failure map are estimated using the results of three-points bending test. From the results of the experiment, the influence of design parameters of ISB panel on the specific stiffness and failure mode has been found. In addition, it has been shown that ISB panel with expanded metal is prefer to that with woven metal from the view point of optimal design for ISB panel.

  • PDF

Heat Transfer Analysis of Friction Welding of A2024 to SM45C (A2024 와 SM45C 마찰용접의 열전달 해석)

  • 이상윤;윤병수
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • The hear transfer mechanism initiating the friction welding is examined and a transient three dimensional heat conduc-tion model for the welding of two dissimilar cylindrical metal bars is investigated. The cylindrical metal bars are made of materials made of A2024 and SM 45C. Numerical simulations of heat flow are performed using the finite volume method. Respectively. Commercial FLUENT code is used in the heat flow simulation and maximum temperature and distribution of temperature are calculated. Temperature of friction welded joining face is compared with the temperature distribution measured by experiment and numerical simulation. The maximum temperature of friction welded joining face is lower than melting point of A2024-T6 aluminum alloy using insert metal. The temperature distribution of friction welded join- ing face with insert metal is more uniform than that of without inset metal.

  • PDF

Electrical Properties of IMI-O Polymer LB Films in Complexed Metal Ion (금속이온 착체에 의한 IMI-O 고분잔 LB막의 전기적 특성)

  • Jung, Sang-Burm;Yoo, Seung-Yeop;Park, Jae-Chul;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1519-1521
    • /
    • 1997
  • In this paper, poly (N-(2-4-imidazolyl) ethyl) maleimide-alt-1-octadecene (IMI-O) polymer which can complex metal ion was used to confirm the possibility of molecular device made by Langmuir-Blodgett method. Metal/Insulator/Metal (MIM) device was fabricated for investigation of electric properties. In the ${\pi}$-A isotherm, surface pressure at collapse point was different as to the molecular weight of metal ion complexed respectively, In I-V characteristics, currents of MiM devices were different at the same voltage. It was thought that phenomena was occurred by interaction between function group and metal ion.

  • PDF

Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap (다공성 수침-평판전극간의 수적 방출 특성)

  • Jung, Jae-Seung;Lee, Woo-Seok;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

Fabrication and Electrical Properties of IMI-O Polymer LB Films (IMI-O 고분자 LB막의 제작 및 전기적 특성)

  • Jeong, Sang-Beom;Yu, Seung-Yeop;Park, Jae-Cheol;Gwon, Yeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.87-91
    • /
    • 2000
  • Metal ion complex of poly(N-(2,4-imidazoly)ethyl)maleimide-alt-l-octadecene (IMO-O) polymer used to confirm the possibility of molecular device made by Langmuir-Blodgett(LB) method. Electrical properties of the metal ion complex LB film were investigated using Metal/Insulator/Metal(MIM) structure. In the surface pressure-area($\pi$-A) isotherm of IMI-O polymer, the surface pressure at collapse point has a difference due to the interaction between polymer and metal ions. And the complex between polymer and metal ions could be verified through the investigation by Raman spectroscopy. In the current-voltage(I-V) property, the conductivity change of IMO-O polymer complexes due to the kinds of metal of metal ions couldn't be observed. However, the limiting area of molecules was changed by the concentration of the metal ions and the conductivity was increased with the occupied molecular area.

  • PDF

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF