• 제목/요약/키워드: Metal on metal

검색결과 17,544건 처리시간 0.049초

금속 가드 링이 SiC 쇼트키 다이오드의 항복전압에 미치는 영향 (Effect on Metal Guard Ring in Breakdown Characteristics of SiC Schottky Barrier Diode)

  • 김성진
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.877-882
    • /
    • 2005
  • In order to fabricate a high breakdown SiC-SBD (Schottky barrier diode), we investigate an effect on metal guard ring (MGR) in breakdown characteristics of the SiC-SBD. The breakdown characteristics of MGR-type SiC-SBD is significantly dependent on both the guard ring metal and the alloying time of guard ring metal. The breakdown characteristics of MGR-type SiC-SBDs are essentially improved as the alloying time of guard ring metal is increased. The SiC-SBD without MGR shows less than 200 V breakdown voltage, while the SiC-SBD with Al MGR shows approximately 700 V breakdown voltage. The improvement in breakdown characteristics is attributed to the field edge termination effect by the MGR, which is similar to an implanted guard ring-type SiC-SBD. There are two breakdown origins in the MGR-type SiC-SBD. One is due to a crystal defects, such as micropipes and stacking faults, in the Epi-layers and the SiC substrate, and occurs at a lower electric field. The other is due to the destruction of guard ring metal, which occurs at a higher electric field. The demolition of guard ring metal is due to the electric field concentration at an edge of Schottky contact metal.

섬유의 적층각과 금속판의 특성에 따른 섬유 금속 적층판의 충격 손상 거동 (Effect of Fiber Orientation Angle and Property of Metal Laminate on Impact Behaviors of Fiber Metal Laminates)

  • 남현욱;정성욱;한경섭
    • 대한기계학회논문집A
    • /
    • 제27권3호
    • /
    • pp.372-380
    • /
    • 2003
  • Impact tests were conducted to study the effect of angle ply and metal laminate on impact damage characteristics of Fiber Metal laminates (FML). Impact tests were conducted using drop weight impact machine and damage behavior were analyzed by comparing with load-displacement curve and surface observation and microscopic observation of cross sections. The effect of angle ply on impact characteristics of FML are influenced by property of metal laminate. i.e., when the metal laminate is not enough to strong to prevent fiber debonding, Angle ply FML is superior to singly oriented ply (SOP) FML because angle ply enhance the stiffness by fiber supports and prevent (rack propagation. However, when the metal laminate is enough to strong to prevent fiber debonding, SOP FML is superior to Angle ply FML because the fiber of lower ply in Angle ply FML are more stressed than that of SOP FML.

다공성 촉매 분리막을 이용한 수증기 개질 반응 특성 연구 (A Study on the Reaction Characteristics of Steam Reforming Reaction over Catalyzed Porous Membrane)

  • 홍성창;이상문
    • 공업화학
    • /
    • 제25권2호
    • /
    • pp.198-203
    • /
    • 2014
  • 본 연구에서는 Ni metal foam 플레이트의 수증기 개질반응 및 표면 특성을 조사하였다. 전처리를 통하여 Ni의 산화상태를 변화시킬 수 있었으며, 활성 site로서 표면에 노출된 metallic Ni 종은 수증기 개질 반응활성에 중요한 역할을 한다. 또한 Ni metal foam 플레이트의 기공제어 및 촉매 기능을 부여하기 위하여 Ni metal foam 플레이트와 Ni-YSZ 촉매를 혼합하여 다공성 촉매 분리막을 제조하였다. SEM 분석 결과 metal foam 플레이트의 기공을 제어할 수 있었으며, 표면에 Ni-YSZ 촉매는 고르게 잘 분포되어 있었다. Ni 기반 다공성 촉매 분리막은 공간속도에 상관없이 상용촉매와 유사한 수증기 개질 활성을 가진다.

Influence on properties of base metal after elimination of lifting-lug member in a dissimilar welding between steel base and steel lifting lug

  • Park, Jeongung;An, Gyubaek;Lee, Haewoo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.858-864
    • /
    • 2019
  • The increasing demands of lifting lugs can be attributed to the rapid advancement of shipbuilding and offshore-structure production technologies and an exponential increase in the size of the block units of ship structures. Therefore, to ensure safety during the transportation and turnover of large blocks, it is important to determine the structural integrity and position of lifting lugs. However, because the manufacturing cost and availability of lugs are important considerations, low cost and easily obtainable steel compositions of grades different from those of the blocks are often used as alternatives. The purpose of this study is to investigate the effect of a lifting-lug metal on the physical properties of a base metal in a dissimilar welding between the base metal and lifting lug. The effect was evaluated by observing the metal microstructures and determining the hardness and dilution values on the cross-sectional surface of the lifting lug. According to the results of the metal microstructures, impact, hardness, and emission spectrochemical analysis at the surface from where the lug was removed confirmed that the chemical composition of the lifting-lug metal did not influence the physical properties of the base metal.

$ CO_2$레이저 합체박판 용접부의 기계적 물성평가 (Evaluation of Mechanical Properties of Welded Metal in Tailored Steel Sheet Welded by $ CO_2$ Laser)

  • 구본영;금영탁
    • 한국정밀공학회지
    • /
    • 제18권4호
    • /
    • pp.142-150
    • /
    • 2001
  • Automotive manufactures have taken more interests in tailored sheet metals for improving the rigidity, weight reduction, crash durability, and cost savings so that their application to auto-bodies has been increased. However, since the tailored sheet metals do not behave like un-welded sheet metals in press forming operations, the stamping engineers no longer rely only on conventional forming techniques. Futhermore, there is no clear understanding of the characteristics of welded metal which influence the overall press formability of tailored sheet metals. Recently, the computer simulations are prevailing for the evaluation of the formability. Unfortunately, the mechanical property of tailored sheet metal has to be quantitatively defined in the simulation. In this study, the analytical equations are formulated in order to find the mechanical properties of the welded metal in the tailored sheet metal welded by co$_2$laser. Based on force distribution assumption, the constitutive behavior of the welded metal is investigated using uniaxial tensile test results of base metals and tailored sheet metal. Then, the strength coefficient, work-hardening exponent, and plastic strain ratio of laser-welded metal are calculate from those of base metals and tailored sheet metal. In addition, the existence of weld defects in the welded metal is indirectly detected by examining the slop of strength coefficient of the welded metal.

  • PDF

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

은계 필러메탈 브레이징 접합부의 특성 분석 (Analysis of Bonding Characteristics of Ag-System Brazing Filler Metal)

  • 이순길;이화인;손진오;하광일;구본흔
    • 한국재료학회지
    • /
    • 제33권5호
    • /
    • pp.214-221
    • /
    • 2023
  • As a filler metal for lowering the melting point of Ag, many alloy metal candidates have emerged, such as cadmium, with zinc, manganese, nickel, and titanium as active metals. However, since cadmium is known to be harmful to the human body, Cd-free filler metals are now mainly used. Still, no study has been conducted comparing the characteristics of joints prepared with and without cadmium. In addition, studies have yet to be conducted comparing the typical characteristics of brazing filler metals with special structures, and the joint characteristics of brazing filler metals with available frames. In this study, the characteristics of junctions of silver-based intercalation metals were compared based on the type of filler metal additives, using a special structure, a filler metal sandwich structure, to protect the internal base metal. The general filler metal was compared using the structure, and the thickness of the filler metal according to the thickness was reached. A comparison of the characteristics of the junction was conducted to identify the characteristics of an intersection of silver-based brazing filler metal and the effect on joint strength. Each filler metal's collective tensile strength was measured, and the relationship between joint characteristics and tensile joint strength was explored. The junction was estimated through micro strength measurement, contact angle measurement with the base metal when the filler metal was melted, XRD image observation, composition analysis for each phase through SEM-EDS, and microstructure phase acquisition.

Magnetic Properties of Transition Metal Monolayers on Ta(001) Surfaces

  • Youn, S.J.;Hong, S.C.
    • Journal of Magnetics
    • /
    • 제13권4호
    • /
    • pp.140-143
    • /
    • 2008
  • The magnetic and structural properties of transition metal (Mn, Fe, Co) monolayers on Ta(001) surfaces are investigated theoretically by using the first principles full-potential linearized augmented plane wave method. Mn and Fe monolayers become ferromagnetic on Ta(001) surfaces while Co monolayers becomes non-magnetic. The paramagnetism of Co monolayers is explained by the Stoner theory of magnetism. The magnetic coupling of a transition metal overlayer with a substrate is ascribed to the orbital hybridization between the s and d orbitals of the transition metal.

Biochemical and Biodiversity Insights into Heavy Metal Ion-Responsive Transcription Regulators for Synthetic Biological Heavy Metal Sensors

  • Jung, Jaejoon;Lee, Sang Jun
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권10호
    • /
    • pp.1522-1542
    • /
    • 2019
  • To adapt to environmental changes and to maintain cellular homeostasis, microorganisms adjust the intracellular concentrations of biochemical compounds, including metal ions; these are essential for the catalytic function of many enzymes in cells, but excessive amounts of essential metals and heavy metals cause cellular damage. Metal-responsive transcriptional regulators play pivotal roles in metal uptake, pumping out, sequestration, and oxidation or reduction to a less toxic status via regulating the expression of the detoxification-related genes. The sensory and regulatory functions of the metalloregulators have made them as attractive biological parts for synthetic biology, and the exceptional sensitivity and selectivity of metalloregulators toward metal ions have been used in heavy metal biosensors to cope with prevalent heavy metal contamination. Due to their importance, substantial efforts have been made to characterize heavy metal-responsive transcriptional regulators and to develop heavy metal-sensing biosensors. In this review, we summarize the biochemical data for the two major metalloregulator families, SmtB/ArsR and MerR, to describe their metal-binding sites, specific chelating chemistry, and conformational changes. Based on our understanding of the regulatory mechanisms, previously developed metal biosensors are examined to point out their limitations, such as high background noise and a lack of well-characterized biological parts. We discuss several strategies to improve the functionality of the metal biosensors, such as reducing the background noise and amplifying the output signal. From the perspective of making heavy metal biosensors, we suggest that the characterization of novel metalloregulators and the fabrication of exquisitely designed genetic circuits will be required.

저온공정 n-InGaAs Schottky 접합의 구조적 특성 (Structural Analysis of Low Temperature Processed Schottky Contacts to n-InGaAs)

  • 이홍주
    • 한국전기전자재료학회논문지
    • /
    • 제14권7호
    • /
    • pp.533-538
    • /
    • 2001
  • The barrier height is found to increase from 0.25 to 0.690 eV for Schottky contacts on n-InGaAs using deposition of Ag on a substrate cooled to 77K(LT). Surface analysis leads to an interface model for the LT diode in which there are oxide compounds of In:O and As:O between the metal and semiconductor, leading to behavior as a metal-insulator-semiconductor diode. The metal film deposited t LT has a finer and more uniform structure, as revealed by scanning electron microscopy and in situ metal layer resistance measurement. This increased uniformity is an additional reason for the barrier height improvement. In contrast, the diodes formed at room temperature exhibit poorer performance due to an unpassivated surface and non-uniform metal coverage on a microscopic level.

  • PDF