• Title/Summary/Keyword: Metal on metal

Search Result 17,544, Processing Time 0.064 seconds

Seed Longevity of Rice Germplasm in the National Agrobiodiversity Center (종자은행 보존 벼 유전자원의 생태형별 종자수명)

  • Na, Young-Wang;Choi, Yu-Mi;Baek, Hyung-Jin;Lee, Sok-Young;Kang, Jung-Hun;Kim, Seok-Hyeon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.3
    • /
    • pp.216-222
    • /
    • 2014
  • The purpose of this study was to know the seed longevity of rice (Oryza sativa L.) germplasm for effective viability monitoring. The longevity was determined via germination tests of 3,066 accessions of rice germplasm from the National Agrobiodiversity Center, Rural Development Administration, Korea. The rice germplasm accessions have been conserved at a mid-term storage ($4^{\circ}C$, 30% RH) in plastic bottle containing dehydrated (blue) silica-gel and long-term storage ($-18^{\circ}C$, 35% RH) in hermetically sealed metal can on either sides for 25~26.5 years. The final germination percentages of 3,066 rice germplasm accessions of $6.5{\pm}1.0%$ seed moisture content with 94% initial germination stored at $4^{\circ}C$ for 26.5 years declined to 47% while at $-18^{\circ}C$ for 25 years maintained high germinability as 93%. Germination time courses, which represent the average performance of rice ecotypes stored at $4^{\circ}C$ and 30% RH, were fitted regression equation, to calculate the time at which germination characteristically declined to 50% ($P_{50}$). These $P_{50}$ values of Indica, Japonica, Javanica and Tongil type in rice were 39.9, 22.9, 25.4 and 31.8 years, respectively. The rice germplasm stored at $4^{\circ}C$ could be clustered in 4 groups using quartile of final germination after 26.5 years storage. The seed longevity ($P_{50}$) of each group was estimated by regression equation of changed germination percentages according to storage periods. The $P_{50}$ values of group I, group II, group III and group IV were 21.1, 23.6, 30.0 and 75.7 years.

Investigation on the Material and Migration Tests of Gas Impermeable Plastic Vacuum Packaging Materials for Food-Contact Use (식품용 합성수지제 공기차단성 포장재에서의 재질 및 용출시험량 조사)

  • Lee, Jung-Pyo;Lee, Youn-Kyu;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.14 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • Twenty eight gas impermeable plastic films for food-contact application were collected in the domestic market and material and/or migration tests for overall migration, antioxidants, potassium permanganate consumption, heavy metal, and plasticizers were carried out. The average overall migration values for NY/PE or NY/LLDPE, PETP/PE, and PVDC packaging films obtained by using n-heptane as fatty food simulant were 7.6, 6.9 and 14.1 mg/L, respectively. These values were much lower than the limit values of 150 and 30 mg/L for polyethylene and polyvinylidene chloride prescribed in the Korea Food Code. In almost of the packaging materials tested, the antioxidants such as Irganox 1010, Irganox 1076 and Irgafos 168 were found. The migration test result showed that almost of all samples except PVDC film contained Irganox 1076 and Irgafos 168, while the maximum migration value of Irganox 1076 into n-heptane was found in the Ny/PE/LLDPE(15/25/50 ${\mu}m$) sample at the concentration of 216.9 ${\mu}g/g$. From the plastic packaging samples tested, plasticizers such as DEP, DPRP, DBP, DPP, BBP, DCHP, DEHP, DEHA and observed above the detection limit. Consumption amount of potassium permanganate was much lower than the limit value of 10 mg/L. In the material test for heavy metals, cadmium and lead were determined at the concentrations far below the limit value of 100 mg/kg. The migration test for cadmium and lead showed a lower value than the detection limit. Therefore, it can be concluded that the safety status of the plastic films tested met the requirement of limit values as prescribed for the material and migration tests of food packaging utensils, containers and packages of the Korea Food Code.

  • PDF

Removal of water pollutants and its application to swine wastewater treatment through the establishment of best optimal growth conditions of Ankistrodesmus bibraianus (Ankistrodesmus bibraianus의 최적 배양조건 설정을 통한 수질오염물질 제거 및 축산 폐수 처리 적용)

  • Hwang, In-Seong;Park, Young-Min;Lee, Ye-Eun;Kim, Deok-Won;Park, Ji-Su;Oh, Eun-Ji;Yoo, Jin;Chung, Keun-Yook
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.82-92
    • /
    • 2020
  • Since swine wastewater contains high concentrations of nutrients and heavy metals, it deteriorates water quality when discharged. Compared to conventional methods, bioremediation can be a promising method for its treatment. Specifically, microalgae have the potential to remove these pollutants. In this study, the removal of nutrients (nitrogen (N) and phosphorus (P)) and heavy metals (copper (Cu) and zinc (Zn)) from swine wastewater by Ankistrodesmus bibraianus was evaluated and the organism's optimal growth conditions were investigated. The optimal growth conditions were established at 28℃, pH 7, and light and dark cycles of 14:10 h. The removal efficiencies of N and P by a single treatment (500, 1,000, 5,000, and 10,000 mg L-1) ranged from 22.9 to 80.6% and from 11.9 to 50.0%, respectively. The removal efficiencies of N and P in the binary treatments ranged from 16.4 to 58.3% and from 7.80 to 49.8%, respectively. The removal efficiencies of Cu and Zn by a single treatment(10, 30, and 50 mg L-1) ranged from 15.5 to 81.5% and from 6.28 to 34.3%, respectively. Similarly, the removal efficiencies of Cu and Zn in the binary treatments ranged from 16.7 to 74.5% and from 5.58 to 27.5%, respectively. In addition, the study showed the optimal growth conditions for microalgae and the removal efficiency of nutrients (N and P) and heavy metals (Cu and Zn), which could be applied to swine wastewater. Based on the results in this study, it appears that Ankistrodesmus bibraianus could be used for the removal of nutrients and heavy metals present in swine wastewater.

Usability Evaluation and Development of Design Prototyping for MP3 Smart Clothing Product (MP3 스마트웨어 제품 상용화를 위한 디자인 프로토타입 개발 및 사용성 평가 연구)

  • Chea, Heang-Suk;Hong, Ji-Young;Kim, Jun-Hee;Kim, Jin-Hyung;Han, Kwang-Hee;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.331-342
    • /
    • 2007
  • This study focused on developing MP3 smart clothing products and usability evaluation. MP3 smart clothing which was developed in this study contains e-textile keypad and a kit. The kit consists of MP3 Player, remote controller module and ear phone, and are easy to assemble and dismantle. And usability evaluation about MP3 smart Clothing which was developed in this study contains e-textile keypad and a kit. For making the MP3 Smart clothing, e-textile signal line and keypad was developed and a metal connection ring also was manufactured to adhere closely e-textile signal line to keypad. The last products are two kinds of MP3 smart clothing, jacket style of MP3-YSJ(Yonsei Smart Jacket) and safari style of MP3-YSS(Yonsei Smart Safari). Then usability evaluation conducted two times about MP3 smart clothing developed. Usability evaluation is classified by a module evaluation and an item evaluation. The module evaluation measured external appearance, material, a music controller, an ear phone(or a mini speaker) and connector. The item evaluation measured social acceptance, feeling of wearing, utility, easiness of maintenance and safety. The module evaluation described totally positive results in the first usability evaluation about MP3-YSJ 1.0 and MP3-YSS 1.0. The item evaluation shows a lower score in the social acceptance, especially the easiness of connector maintenance and the social acceptance of music-controller in MP3-YSJ 1.0 and MP3-YSS 1.0. The second usability evaluation conducted with improved products by the first usability test results. Results from second item evaluation indicated needs to improve the easiness of connector & music-controller maintenance and the social acceptance of music-controller in MP3-YSJ 2.0. In MP3-YSS 2.0, the easiness of material management and the social acceptance of music controller & connector needed to improvement. In particular, users felt inconvenience in the social acceptance because of e-textile keypad arrangement. To outweigh this disadvantage, further study is needed about keypad interface of the music controller.

  • PDF

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Relationship between Violent Criminal Behavior and Imbalance of Scalp Hair Minerals in Man (두발중 미량 중금속과 필수금속의 과다 또는 과소의 불균형과 폭력범죄 행동과의 관련성 연구)

  • Kim, Doo-Hie;Jang, Bon-Ki;Lee, Duk-Hee;Hong, Sung-Chul;Kim, Byung-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.25-43
    • /
    • 1994
  • To estimate the factors to the inclination of the criminal violence, the content of trace minerals and toxic metals in the scalp hair were measured during the period from May 1992 to October 1992. One hundred eleven violent and 89 nonviolent criminal inmates of Taegu Correctional Institute were selected. The inmates of violent criminals were imprisoned by murder, robber, rape, injury and violent acts. Those of nonviolent criminals were swindle, larceny, and adultery and had no history of institutional violence. The contents of two toxic metals (cadmium, lead) and five trace minerals (Cu, Fe, Zn, Mg, Na) were determined by an atomic absorption spectrophotometer (IL. 551). The contents of cadmium and lead in hair of violent criminals were significantly higher as $0.56{\pm}0.14ppm,\;11.53{\pm}3.32ppm$, respectively, than $0.42{\pm}0.20ppm,\;9.63{\pm}4.31ppm$ of nonviolent group (p<0.01). But the level of copper was significantly lower than nonviolent group (p<0.05). The factors that had a significant correlation with the inclination of violence in multiple logistic regression analysis were cadmium (odds ratio=98.09), unmarried (odds ratio=0.39), many times of criminal history(odds ratio=1.57) and residence of rural area (odds ratio=0.44). The results suggest that the sub-toxic contents of cadmium and lead in the hair may be of potential effect on behavior, and the mineral analysis may be an important adjunctive diagnostic procedure. Further studies into this problem are necessary.

  • PDF

Survey of Heavy Metal Contents of Circulating Agricultural Products in Korea (국내 유통 중인 농산물의 중금속 함량 모니터링)

  • Kim, Hee-Yun;Kim, Jae-In;Kim, Jin-Chul;Park, Ji-Eun;Lee, Kyung-Jin;Kim, Sung-Il;Oh, Jae-Ho;Jang, Young-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.238-244
    • /
    • 2009
  • This survey was conducted as a surveillance program following the establishment of safety guidelines for agricultural products in Korea. Concentrations of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) were measured in 421 samples using a mercury analyzer or ICP-MS. The average levels of Pb in mg/kg were 0.021 for rice, 0.020 for corn, 0.028 for soybeans, 0.034 for red beans, 0.025 for sweet potatoes, 0.021 for potatoes, 0.019 for Chinese cabbage, 0.031 for spinach, 0.021 for Welsh onions, and 0.011 for radishes. The average levels of Cd in mg/kg were 0.021 for rice, 0.002 for corn, 0.020 for soybeans, 0.006 for red beans, 0.008 for sweet potatoes, 0.011 for potatoes, 0.007 for Chinese cabbage, 0.035 for spinach, 0.006 for Welsh onions, and, 0.006 for radishes. The average levels of As in mg/kg were 0.103 for rice, 0.005 for corn, 0.007 for soybeans, 0.005 for red beans, 0.005 for sweet potatoes, 0.004 for potatoes, 0.007 for Chinese cabbage, 0.015 for spinach, 0.009 for Welsh onions and, 0.006 for radishes. Finally, the average levels of Hg in ${\mu}g/kg$ were 2.3 for rice, 0.2 for corn, 0.6 for soybeans, 1.4 for red beans, 0.1 for sweet potatoes, 0.3 for potatoes, 0.5 Chinese cabbage, 2.1 for spinach, 0.5 for Welsh onions, and 0.2 for radishes. Based on the Korean public nutrition report 2005, these levels (or amounts) are calculated only at 2.6% for Pb, 8.7% for Cd, 1.2% for Hg of those presented in provisional tolerable weekly intake (PTWI) which has been established by FAO/WHO. Therefore, the levels presented here are presumed to be adequately safe.

Safety Assessment of Oriental Medicines and Their Preparations (한약 및 한약제제의 안전성 평가)

  • Jeong, Il-Hyung;Kim, Jong-Hwa;Jeon, Jong-Sup;Cho, Sang-Hun;Park, Shin-Hee;Jo, Hyun-Ye;Kim, Young-Sug
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.232-237
    • /
    • 2010
  • This study was carried out to evaluate the safety of circulated oriental medicines and their related preparations in Gyeonggi-do. Total 366 samples (165 species) were analyzed about heavy metals, residual contents of sulfur dioxide ($SO_2$), and 68 samples were analyzed about preservatives. 17 samples (13 species, 4.6%) were exceeded the legal limit of heavy metal. The concentrations over the legal limit for Pb, Cd, As and Hg were 6.1~19.2 mg/kg, 0.4~0.7 mg/kg, 6.9 mg/kg and 0.7 mg/kg, respectively. In particular, the exceeding ratio (5.9%) of the legal limit of heavy metals in foreign products was 3.3 times more than domestic products (1.8%). 13 samples (10 species, 3.6%) exceeded the limit of residual sulfur dioxide and the concentration ranges were 105 to 428 mg/kg in domestic products, on the other hand foreign products were from 114 to 2,468 mg/kg. The mean concentration over the limit of residual sulfur dioxide of foreign products (804 mg/kg) was 2.4 times more than domestic products (338 mg/kg). In studying of the preservatives in oriental preparation, the contents of dehydroacetic acid (48.9~64.1%) in 3 samples of labeled solutions were under the labeled preservative contents and the contents of benzoic acid (139.9%) in 1 sample of labeled pill product was exceeded the labeled preservative contents. The numbers of the detected preservatives in unlabeled solutions, pills and granules were 4, 11 and 7, respectively.

A study on the concentration of trace metal elements in whole blood of the women in reproductive ages in urban and rural area (도시 및 농촌지역 가임연령 여성들의 혈중 미량금속원소의 함량에 관한 조사)

  • Jun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.95-106
    • /
    • 1984
  • To acquire the essential basic data to the establishment of control measure for the hazardous health effect that could be caused by harmful metals, the author measured the concentrations of trace metals in whole blood of women of $20{\sim}39$ years old living in urban and rural area using atomic absorption spectrophotometer. The summarized results were as follows; 1. The mean concentration of zinc in whole blood was $10.69{\pm}8.07{\mu}g/ml$ in rural area. The frequency distribution by zinc concentration level was nearly L-type and the cumulative frequency distribution was showed bimodal type in both area. 2. The mean iron concentration in whole blood was $323.09{\pm}87.15{\mu}g/ml$ and $322.07{\pm}104.74{\mu}g/ml$ in urban and rural area, respectively. The frequency distribution was similar to normal distribution type in both area, but the cumulative distribution was unimodal type in urban area and bimodal type in rural area. 3. The mean magnesium concentration was $41.08{\pm}19.58{\mu}g/ml$ and $40.28{\pm}16.82{\mu}g/ml$ in the area, respectively. The frequency distribution type had skewness to the right and the cumulative frequency distribution was unimodal type in both area. 4. The mean copper concentration was $1.417{\pm}0.761{\mu}g/ml$ and $1.375{\pm}0.743{\mu}g/ml$ in the area, respectively. The frequency distribution type had skewness to the right and the cumulative frequency distribution was bimodal type in both area. 5. The mean manganese concentration was $0.079{\pm}0.039{\mu}g/ml$ and $0.07{\pm}0.058{\mu}g/ml$ in the area, respectively. The frequency distribution type had skewness to the right in both area but slight irregular in rural area and the cumulative distribution was unimodal and bimodal type in urban and rural area, respectively. 6. The mean cadmium concentration in whole blood was $0.031{\pm}0.026{\mu}g/ml$ in urban and $0.028{\pm}0.023{\mu}g/ml$ in rural area. The frequency distribution type had skewness to the right and cumulative frequency distribution was bimodal type in both area.

  • PDF

A Study of the Utilization of Feldspathic Sand as a Fortified Functional Filtering Material for Water Purification (고 기능성 수질 정화 여과재로서의 장석질 모래 활용연구)

  • 고상모;송민섭;홍석정
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.283-293
    • /
    • 2003
  • Domestic water treatment plants operate the rapid and slow filtering system using the filtering sands. Most of them are composed of beach sands, which have less sorption capacity of heavy metals as well as organic contaminants. Therefore, the development of fortified functional filtering materials with high removal capacity of organic and inorganic contaminants is needed to prevent the unexpected load of contaminated source water. This study aims to test the hydrochemical change and the removing capacity of heavy metals such as Cd, Cu, and Pb on the Jumunjin sand, feldspathic sand(weathering product of Jecheon granite), feldspathic mixing sand I(feldspathic sand mixed with 10 wt% zeolite), and feldspathic mixing sand II (feldspathic sand mixed with 20 wt% zeolite). Feldspathic mixing sand I and II showed the eruption of higher amounts of cations and anions compared with the Jumunjin sand and feldspathic sand. They also showed higher eruption of Si, Ca, $SO_4$ ions than that of Al, $NO_3$, Fe, K, Mg, and P. Feldspathic mixing sand II caused higher eruption of some cations of Na, Ca, Al than feldspathic mixing sud I, which is the result controlled by the dissolution of zeolite. Jumunjin sand and feldspathic sand showed very weak sorption of Cd, Cu and Pb. In contrast to this, feldspathic mixing sand I and II showed the high sorption and removal capacity of the increasing order of Cd, Cu and Pb. Feldspathic mixing sand II including 20% zeolite showed a fortified removal capacity of some heavy metals. Therefore, feldspathic mixing sand mixed with some contents of zeolite could be used as the fortified filtering materials for the water filtering and purification in the domestic water treatment plants.