• Title/Summary/Keyword: Metal on metal

Search Result 17,544, Processing Time 0.062 seconds

Heavy Metal Contents in Dfferent Bran Layers of Rice (미곡중(米穀中) 도정부위별(搗精部位別) 중금속함량(重金屬含量))

  • Kim, Myung-Chan;Shim, Ki-Hwan;Chung, Duck-Hoa;Cho, Ki-Taik
    • Applied Biological Chemistry
    • /
    • v.23 no.3
    • /
    • pp.141-149
    • /
    • 1980
  • Contents of heavy metals in various bran layers of rice collected from Kyeong Nam province in 1978, were determined. The components of crude prote in, crude fat, crude cellulose, and ash in all the rice samples were found to be most concentrated in the rice of each layer of brown, 70% polished, and 90% polished, but the contents of crude protein (9.22%), crude fat (1.16%), crude cellulose (1.01%), and ash (0.38%) in polished rice decreased rapidly. On the other hand, the amounts of nitrogenfree extract in the rice were showed increasingly toward the inner layer and those of polished rice were 75.54%. The contents of lead, zinc, nickel, cadmium, and arsenic in bran layer of rice decreased in order of that of 90% polished, 70% polished, brown, and polished rice. Their amounts in polished rice were lead, $0.054{\sim}0.610ppm$; zinc, $9.830{\sim}19.093ppm$; nickel, trace-1.776ppm; cadmium, trace-0.039ppm; arsenic, ND-0.170ppm. It was shown that copper was more concentrated in the layer of 90% polished rice $(0.581{\sim}1.476ppm)$, and iron more in brown rice $(27.971{\sim}66.569ppm)$ than in any other portion, whereas mercury $(0.006{\sim}0.072ppm)$, chromium $(1.538{\sim}7.822ppm)$, and manganese $(57.371{\sim}179.252ppm)$ were much contained in the layer of 70% polished rice. Their amounts in polished rice were copper, $0.218{\sim}0.858ppm$; iron, $1.480{\sim}9.573ppm$; mercury, $0.006{\sim}0.027ppm$; chromium, ND-1.520ppm; and manganese, $6.730{\sim}11.562ppm$.

  • PDF

Characterization and annealing effect of tantalum oxide thin film by thermal chemical (열CVD방법으로 증착시킨 탄탈륨 산화박막의 특성평가와 열처리 효과)

  • Nam, Gap-Jin;Park, Sang-Gyu;Lee, Yeong-Baek;Hong, Jae-Hwa
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.42-54
    • /
    • 1995
  • $Ta_2O_5$ thin film IS a promising material for the high dielectrics of ULSI DRAM. In this study, $Ta_2O_5$ thin film was grown on p-type( 100) Si wafer by thermal metal organic chemical vapo deposition ( MCCVD) method and the effect of operating varialbles including substrate temperature( $T_s$), bubbler temperature( $T_ \sigma$), reactor pressure( P ) was investigated in detail. $Ta_2O_5$ thin film were analyzed by SEM, XRD, XPS, FT-IR, AES, TEM and AFM. In addition, the effect of various anneal methods was examined and compared. Anneal methods were furnace annealing( FA) and rapid thermal annealing( RTA) in $N_{2}$ or $O_{2}$ ambients. Growth rate was evidently classified into two different regimes. : (1) surface reaction rate-limited reglme in the range of $T_s$=300 ~ $400 ^{\circ}C$ and (2: mass transport-limited regime in the range of $T_s$=400 ~ $450^{\circ}C$.It was found that the effective activation energies were 18.46kcal/mol and 1.9kcal/mol, respectively. As the bubbler temperature increases, the growth rate became maximum at $T_ \sigma$=$140^{\circ}C$. With increasing pressure, the growth rate became maximum at P=3torr but the refractive index which is close to the bulk value of 2.1 was obtained in the range of 0.1 ~ 1 torr. Good step coverage of 85. 71% was obtained at $T_s$=$400 ^{\circ}C$ and sticking coefficient was 0.06 by comparison with Monte Carlo simulation result. From the results of AES, FT-IR and E M , the degree of SiO, formation at the interface between Si and TazO, was larger in the order of FA-$O_{2}$ > RTA-$O_{2}$, FA-$N_{2}$ > RTA-$N_{2}$. However, the $N_{2}$ ambient annealing resulted in more severe Weficiency in the $Ta_2O_5$ thin film than the TEX>$O_{2}$ ambient.

  • PDF

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.

Soft X-ray Synchrotron-Radiation Spectroscopy Study of [Co/Pd] Multilayers as a Function of the Pd Sublayer Thickness (Pd층의 두께 변화에 따른 [Co/Pd] 다층박막의 연엑스선 방사광 분광 연구)

  • Kim, D.H.;Lee, Eunsook;Kim, Hyun Woo;Seong, Seungho;Kang, J.-S.;Yang, Seung-Mo;Park, Hae-Soo;Hong, JinPyo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.124-128
    • /
    • 2016
  • We have investigated the electronic structures of intermetallic multilayer (ML) films of [$Co(2{\AA})/Pd(x{\AA})$] (x: the thickness of the Pd sublayer; x = $1{\AA}$, $3{\AA}$, $5{\AA}$, $7{\AA}$, $9{\AA}$) by employing soft X-ray absorption spectroscopy (XAS) and soft X-ray magnetic circular dichroism (XMCD). Both Co 2p XAS and XMCD spectra are found to be similar to one another, as well as to those of Co metal, providing evidence for the metallic bonding of Co ions in [Co/Pd] ML films. By analyzing the measured Co 2p XMCD spectra, we have determined the orbital magnetic moments and the spin magnetic moments of Co ions in [$Co(2{\AA})/Pd(x{\AA})$] ML films. Based on this analysis, we have found that the orbital magnetic moments are enhanced greatly when x increases from $1{\AA}$ to $3{\AA}$, and then do not change much for $x{\geq}3{\AA}$. This finding suggests that the interface spin-orbit coupling plays an important role in determining the perpendicular magnetic anisotropy in [Co/Pd] ML films.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Soil Environmental Characteristics Assessment of the Namsan Park in Seoul (서울남산의 토양환경특성 평가)

  • Kim, Ik-Soo;Lee, Jai-Young;Kim, Gyeo-Bung;Eom, Seok-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.22-29
    • /
    • 2008
  • To understand environmental characteristics and contamination assessment of the Namsan Park soil in Seoul, we divided the Namsan map into 33 sectors and sampled mixed soil in depth 0${\sim}$15 cm, in 5${\sim}$10 points at the sites. We analyzed soil samples collected at 21 sectors twice on May and September. The results were as follows. The hue color ranges of the Namsan soil were 2.5YR${\sim}$10YR, the value ranges were 1${\sim}$4, the water rates were 3.1${\sim}$22.3 and the Ignition losses were 3.4${\sim}$10.4%. The average concentration of Cu and Pb were determined 3.374 and 15.000 mg/kg, Cd and As showed very low level. The mean concentrations of Zn and Ni were showed 103.290 and 11.649 mg/kg and this amount is not different from the nationalwide mean in 2005. The mean pH showed 5.41. The Zn, Ni and Cd in the soil of the circular road of Namsan showed 1.33, 1.48, 1.46 times higher than the other sector of the Namsan soil. The corelation coefficient between water rate and ignition loss were 0.720 and the correlation coefficient between Cu and Pb, Cu and Zn showed 0.827, 0.694 respectively. There was weak corelationship between pH and Zn. The Uniformity coefficient (Uc) of all the survey sites was determined below 5 in the range of 1.5${\sim}$4.4.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

Determination of Adsorption Isotherms of Hydrogen at an Ir Electrode Interface Using the Phase-Shift Method and Correlation Constants (Ir 전극 계면에서 위상이동 방법 및 상관계수를 이용한 수소의 흡착동온식 결정)

  • Jeon, Sang-K.
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.132-140
    • /
    • 2007
  • The phase-shift method and correlation constants for studying a linear relationship between the behavior ($-{\varphi}\;vs.\;E$) of the phase shift ($0^{\circ}{\leq}-{\varphi}{\leq}90^{\circ}$) for the optimum intermediate frequency and that (${\theta}\;vs.\;E$) of the fractional surface coverage ($1{\geq}\theta{\geq}0$) have been proposed and verified to determine the Langmuir, Frumkin, and Temkin adsorption isotherms (${\theta}\;vs.\;E$) at noble metal/aqueous electrolyte interfaces. At an Ir/0.1 M KOH aqueous electrolyte interface, the Langmuir and Temkin adsorption isotherms (${\theta}\;vs.\;E$), equilibrium constants ($K=3.3{\times}10^{-4}\;mol^{-1}$ for the Langmuir and $K=3.3{\times}10^{-3}{\exp}(-4.6{\theta})\;mol^{-1}$ for the Temkin adsorption isotherm), interaction parameter (g = 4.6 for the Temkin adsorption isotherm), and standard free energies (${\Delta}G_{ads}^0=19.9kJ\;mol^{-1}\;for\;K=3.3{\times}10^{-4}\;mol^{-1}$ and $16.5<{\Delta}G_{\theta}^0<23.3\;kJ\;mol^{-1}\;for\;K=3.3{\times}10^{-3}{\exp}(-4.6{\theta})\;mol^{-1}\;and\;0.2<\theta<0.8$) of H for the cathodic $H_2$ evolution reaction are determined using the phase-shift method and correlation constants. The inhomogeneous and lateral interaction effects on the adsorption of H are negligible. At the intermediate values of ${\theta},\;i.e,\;0.2<{\theta}<0.8$, the Temkin adsorption isotherm (${\theta}\;vs.\;E$) correlating with the Langmuir or the Frumkin adsorption isotherm (${\theta}\;vs.\;E$), and vice versa, is readily determined using the correlation constants. The phase-shift method and correlation constants are accurate and reliable techniques to determine the adsorption isotherms (${\theta}\;vs.\;E$) and related electrode kinetic and thermodynamic parameters(K, g, ${\Delta}G_{ads}^0, {\Delta}G_{\theta}^0$).

Antioxidant Effect of Hederagenin 3-O-b-D-Glucopyranosyl(1→3)-a-L-Rhamnopyranosyl(1→2)-a-L-Arabinopyranoside (HDL) Isolated from Root Bark of Ulmus davidiana (유근피로부터 분리한 hederagenin 3-O-b-D-glucopyranosyl(1→3)-a-L-rhamnopyranosyl(1→2)-a-L-arabinopyranoside (HDL)의 항산화 효과)

  • Bong, Jin-Gu;Park, Yoon-Yub
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.281-291
    • /
    • 2010
  • We investigated the antioxidant effects of hederagenin 3-O-b-D-glucopyranosyl($1{\rightarrow}3$)-a-L-rhamnopyranosyl($1{\rightarrow}2$)-a-L-arabinopyranoside (HDL) isolated from root bark of Ulmus davidiana on the activity of enzymes related to reactive oxygen species (ROS) in human osteosarcoma U2OS cells. Cobalt chloride ($CoCl_2$), a transition metal, was used as an inducer of oxidative stress, generating hydrogen peroxide ($H_2O_2$) via increasing xanthine oxidase (XO) activity. The increased levels of $H_2O_2$, XO, ferritin, and ferritin iron by $CoCl_2$ were diminished effectively by co-treatment with HDL in U2OS cells. Furthermore, decreased levels of antioxidant enzymes such as superoxide dismutase (SOD), catalase (CAT) by $CoCl_2$ were highly increased by co-treatment with HDL in U2OS cells; however, the levels of glutathione peroxidase (GPx) did not change. The increased contents of TBARS related to lipid peroxidation were significantly reduced by HDL in U2OS cells. The concentration of GSH changed in a pattern that went against regulated TBARS by $CoCl_2$ and HDL. We examined the expression of p53, $p21^{CIP1/WAF1}$, and $p27^{KIP1}$ proteins related to oxidative stress and cell cycle regulation. As a result, the expression of $p27^{KIP1}$ modulated by $CoCl_2$ was not changed by HDL. However, the expression of p53 and $p21^{CIP1/WAF}$ increased by $CoCl_2$ was reduced by HDL in U2OS cells. Together with alteration of p53 and $p21^{CIP1/WAF1}$ proteins, the accumulated cells at G1 phase by $CoCl_2$ was decreased by HDL in U2OS cells. Our data suggests that HDL inhibits $CoCl_2$-generated ROS in U2OS cells, providing potentially new antioxidant compounds that are isolated from natural products.