Fabrication and Electrical Properties of IMI-O Polymer LB Films (IMI-O 고분자 LB막의 제작 및 전기적 특성)

  • Jeong, Sang-Beom;Yu, Seung-Yeop;Park, Jae-Cheol;Gwon, Yeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.87-91
    • /
    • 2000
  • Metal ion complex of poly(N-(2,4-imidazoly)ethyl)maleimide-alt-l-octadecene (IMO-O) polymer used to confirm the possibility of molecular device made by Langmuir-Blodgett(LB) method. Electrical properties of the metal ion complex LB film were investigated using Metal/Insulator/Metal(MIM) structure. In the surface pressure-area($\pi$-A) isotherm of IMI-O polymer, the surface pressure at collapse point has a difference due to the interaction between polymer and metal ions. And the complex between polymer and metal ions could be verified through the investigation by Raman spectroscopy. In the current-voltage(I-V) property, the conductivity change of IMO-O polymer complexes due to the kinds of metal of metal ions couldn't be observed. However, the limiting area of molecules was changed by the concentration of the metal ions and the conductivity was increased with the occupied molecular area.

  • PDF

Characteristics of heavy metal adsorption by Korean marine algae

  • Park, Jun-Sub;Park, Chang-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.252-256
    • /
    • 2005
  • Removal of heavy metal ions from aqueous solution by brown sea weeds (Hizikia fusiformis, Laminaria, and Undaria pinnatifida) was 80-96% for lead, cadmium, chromium and copper ions. Fifty percent of the adsorption was completed in 4 min. The uptake of lead and cadmium ions followed Langmuir adsorption. In the adsorption experiments using single and multi metal ions 80-95% of metal ions were removed, and the removal efficiency was the best for lead ion.

  • PDF

Separation of Alkali and Alkaline Earth Metal Ions using Novel HDBPDA Ion Exchanger and Its Ion Exchange Characteristics (새로운 HDBPDA 이온교환체를 사용한 알칼리 및 알칼리토금속 이온들의 분리와 그의 이온교환특성)

  • Kim, Dong-Won;Kim, Chang-Suk;Choi, Ki-Young;Jeon, Young-Shin;Yoon, Yeo-Hag
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.9
    • /
    • pp.820-825
    • /
    • 1993
  • The ion exchange capacity of HDBPDA ion exchanger, {(4,5) : (13,14)-dibenzo-6,9,12-trioxa-3,15,21-triazabicyclo[15.3.l]heneicosa-(1,17,19)(18,20,21) triene ion exchanger: HDBPDA ion exchanger} was 3.8 meq/g. The distribution coefficients of alkali and alkaline earth metal ions in water and the various concentration of hydrochloric acid were determined. Concentration of hydrochloric acid have almost not influenced on the distribution coefficients of alkali and alkaline earth metal ions, but generally, the distribution coefficient was slightly increased with decrease of concentration of hydrochloric acid. The distribution coefficients of metal ions in water are larger than those of various hydrochloric acid concentrations. Also, alkali and alkaline earth metal ions are separated by column ion exchange chromatography using HDBPDA ion exchange with water as eluent. The distribution coefficents of alkali and alkaline earth metal ions were increased with increase of ionic radii of metal ions.

  • PDF

Effect of Metal Ions on the Sedimentation of Humic Acid (흄산의 침적에 미치는 금속이온의 영향)

  • Park, Yeong Jae;Park, Kyoung Kyun;Chun, Kwan Sik
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.1
    • /
    • pp.50-58
    • /
    • 1996
  • In the presence of metal ions(Co(Ⅱ), Ni(Ⅱ), Sr(Ⅱ), Cu(Ⅱ), Fe(Ⅲ), U(Ⅵ)), the sedimentation of humic acid was increased at constant pH with increasing metal concentration and the strength was increased in the following order: Sr < Ni < Co < Cu < Fe < U. At constant metal concentration, Cu(Ⅱ), Ni(Ⅱ), and Co(Ⅱ) ions caused an increase in sedimentation of humic acid as the solution pH increased, whereas Fe(Ⅲ) and U(Ⅵ) ions caused a decrease. Sr(Ⅱ) ions did not affect the sedimentation even with the variation of pH. The analysis of FT-IR spectra for the sediments prepared from the reaction between humic acid and metal ions showed that metal ions were bound to humic acid to form complexes, suggesting that the metal complexation plays an important role in the sedimentation of humic acid.

  • PDF

Effects of Fineness of Chitosan Fiber on the Adsorption Characteristics of Metal Ion (금속이온흡착 특성에 미치는 키토산 섬유 굵기의 영향)

  • 최해욱;정영진;이명환;이순장;박수영;이신희
    • Textile Coloration and Finishing
    • /
    • v.15 no.3
    • /
    • pp.146-153
    • /
    • 2003
  • This article describes the metal ions adsorption of chitosan fibers. The chitosan fibers were manufactured by wet spinning using 2% acetic acid as solvent, 10% aqueous sodium hydroxide as non solvent, and 4%chitosan solution as a solvent. The adsorption characteristics of chitosan fibers towards 100ppm solutions of various metal ions such as Cu(II), Cd(II), Cr(III), Hg(II) were examined at different pH value by ICP-Atomic Emission Spectrometer. The adhesiveness of metallic ions to the chitosan fiber were increased with the increase of pH and the decrease of denier. On the other hand, from pH4, chitosan fiber that is immersed in metal ion aqueous solution of Cu(II) and Cd(II) became homogeneous solution because is dissolved. The adhesiveness of metallic ions to chitosan fiber were found to increased in a sequence of Hg(II)> Cr(III)> Cu(II)> Cd(II). The antimicrobial characteristics of the chitosan fiber by adhered metal ions, virgin chitosan fiber, and cotton fiber were evaluated. The antimicrobial activity of the fibers were increased with the decrease of denier.

A Study on the Fixed-bed Adsorption of Heavy Metal Ions over Chitosan Bead (키토산 비드에 의한 중금속 이온의 고정층 흡착에 관한 연구)

  • Chung, Kyong-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.166-172
    • /
    • 1999
  • Fixed-bed adsorption of metal ions on chitosan bead was studied to remove heavy metal ions in waste water. Chitin was extracted from carb shell and chitosan was prepared by deacetylation of the chitin. The chitosan in bead was used as an adsorbent for heavy metal ions. Freundlich and Langmuir isotherm was determined from the experimental results of equilibrium adsorption for individual metal ion ($Cu^{2+}$, $Co^{2+}$, $Ni^{2+}$) on chitosan bead. Adsorption strength of metal ions decreased in the order of $Cu^{2+}$>$Co^{2+}$>$Ni^{2+}$ ion. Breakthrough curves of single and multicomponent adsorption for metal ions were obtained from the experimental results of fixed-bed adsorption. The breakthrough curves were analyzed by simulation with fixed-bed adsorption equation based on LDFA (linear driving force approximation) adopted LAS (ideal adsorbed solution) theory which can predict multi-component adsorption isotherm from individual adsorption isotherm. The behavior of fixed bed adsorption for single and multi-component system could be nicely simulated by the equation.

  • PDF

Removal of Divalent Heavy Metal Ions by Na-P1 Synthesized from Jeju Scoria (제주 스코리아로부터 합성된 Na-P1 제올라이트에 의한 2가 중금속 이온의 제거특성)

  • Kam, Sang-Kyu;Hyun, Sung-Su;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1337-1345
    • /
    • 2011
  • The removal performances of divalent heavy metal ions ($Pb^{2+}$, $Cu^{2+}$, $Cd^{2+}$, $Sr^{2+}$ and $Mn^{2+}$) were studied using the Na-P1 zeolite synthesized from Jeju scoria in the batch and continuous fixed column reactor. The uptakes of heavy metal ions by synthetic Na-P1 zeolite decreased in the order of $Pb^{2+}$ > $Cu2^{2+}$ > $Cd^{2+}$ > $Sr^{2+}$ > $Mn^{2+}$ based on the selectivity of each ion to ionic exchange site of Na-P1 zeolite for single and mixed solutions in batch or continuous fixed column reactor. For mixed solution, each heavy metal ion uptake was lower than that in single solution, and especially the uptake for $Mn^{2+}$ decreased greatly. In batch reactor, the uptakes of heavy metal ions by synthetic Na-P1 zeolite were described by Freundlich or Langmuir equation, but they followed the former better than the latter. In continuous fixed column reactor, the maximum ion exchange capacity obtained for each of heavy metal ions, was about 90----- of that in batch reactor. The uptakes of heavy metal ions by synthetic Na-P1 zeolite increased with the increase of initial heavy metal concentration and solution pH, and the decrease of the amount and particle size of synthetic zeolite.

Pyrene Appended Hg2+-selective Fluoroionophore Based upon Diaza-Crown Ether

  • Choi, Myung-Gil;Kim, Hee-Jung;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.567-570
    • /
    • 2008
  • A new pyrene appended diaza-18-crown-6 ether derivative 1 has been prepared and its fluoroionophoric properties toward transition metal ions were investigated. Compound 1 exhibited a high Hg2+-selectivity over other transition metal ions as well as alkali and alkaline earth metal ions in aqueous acetonitrile solution. The ratiometric analysis of the monomer and excimer emissions of pyrene successfully signals the presence of Hg2+ ions. The detection limit for Hg2+ ions was found to be 3.1 ´ 10-6 M in 50% aqueous acetonitrile solution at pH 8.1. Competition experiments also suggest that the compound could be utilized as a selective and sensitive fluorescent chemosensor for the analysis of micromolar Hg2+ ions in physiological and environmental samples.

Glass strengthening and coloring using PIIID technology

  • Han, Seung-Hee;An, Se-Hoon;Lee, Geun-Hyuk;Jang, Seong-Woo;Whang, Se-Hoon;Yoon, Jung-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.178-178
    • /
    • 2016
  • Every display is equipped with a cover glass to protect the underneath displaying devices from mechanical and environmental impact during its use. The strengthened glass such as Gorilla glass.$^{TM}$ has been exclusively adopted as a cover glass in many displays. Conventionally, the strengthened glass has been manufactured via ion-exchange process in wet salt bath at high temperature of around $500^{\circ}C$ for hours of treatment time. During ion-exchange process, Na ions with smaller diameter are substituted with larger-diameter K ions, resulting in high compressive stress in near-surface region and making the treated glass very resistant to scratch or impact during its use. In this study, PIIID (plasma immersion ion implantation and deposition) technique was used to implant metal ions into the glass surface for strengthening. In addition, due to the plasmonic effect of the implanted metal ions, the metal-ion implanted glass samples got colored. To implant metal ions, plasma immersion ion implantation technique combined with HiPIMS method was adopted. The HiPIMS pulse voltage of up to 1.4 kV was applied to the 3" magnetron sputtering targets (Cu, Ag, Au, Al). At the same time, the sample stage with glass samples was synchronously pulse-biased via -50 kV high voltage pulse modulator. The frequency and pulse width of 100 Hz and 15 usec, respectively, were used during metal ion implantation. In addition, nitrogen ions were implanted to study the strengthening effect of gas ion implantation. The mechanical and optical properties of implanted glass samples were investigated using micro-hardness tester and UV-Vis spectrometer. The implanted ion distribution and the chemical states along depth was studied with XPS (X-ray photo-electron spectroscopy). A cross-sectional TEM study was also conducted to investigate the nature of implanted metal ions. The ion-implanted glass samples showed increased hardness of ~1.5 times at short implantation times. However, with increasing the implantation time, the surface hardness was decreased due to the accumulation of implantation damage.

  • PDF

Continuous Ion Exchange Characteristics of Ni, Co and Ag Ions in Acidic-Oxidizing Conditions (산성-산화성 분위기에서 니켈(Ni), 코발트(Co) 및 은(Ag) 이온의 연속식 이온교환 특성)

  • Kim, Young H.;Yang, Hyun S.;Kim, Woong K.
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.218-224
    • /
    • 1999
  • Continuous ion exchange characteristics of the synthetic coolant contained Ni, Co and Ag ions of low concentration in acidic-oxidizing conditions have been studied to suggest the guideline for the optimum operation of mixed-bed demincralizer during the shutdown period of a pressurized water reactor (PWR). In the effect of the form of cation resins on the removal capacity of metal ions, the performance of a $H^+$-form resin was about 6% higher than that of a $Li^+$-form resin. Mixed-bed of cation and anion resins in comparison with nonmixed-bed of them, had no affected on the removal capacity of metal ions but very slightly increased the slope of breakthrough curves of metal ions. In the effect related to acidic-oxidizing conditions of the coolant, the addition of boric acid very slightly decreased the slope of breakthrough curves of metal ions, while the addition of hydrogen peroxide slightly decreased the removal capacity of metal ions.