• Title/Summary/Keyword: Metal inlay

Search Result 23, Processing Time 0.028 seconds

The effect of ultrasonic nano crystal surface modification for mitigation of the residual stress after weld inlay on the alloy 82/182 dissimilar metal welds of reactor vessel in/outlet nozzles (원자로 입출구 노즐 Alloy 82/182 이종금속 용접부 Weld Inlay 적용 후 초음파나노표면개질이 잔류응력 완화에 미치는 영향)

  • Cho, Hong Seok;Park, Ik Keun;Jung, Kwang Woon
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.40-46
    • /
    • 2015
  • This study was performed to investigate the effect of ultrasonic nano crystal surface modification (UNSM) on residual stress mitigation after Weld Inlay repair for butt dissimilar metal weld with Alloy 82/182 in reactor vessel In/Outlet nozzle. As-welded and Weld Inlay specimens were made in accordance with design standard of ASME Code Case N-766, and two planes of their weld specimens were peened by the optimum UNSM process condition. Peening characteristics for weld specimens after UNSM treatment were evaluated by surface roughness and Vickers hardness test. And, residual stress for weld specimens developed from before and after UNSM treatment was measured and evaluated by instrumented indentation technique. Consequently, it was revealed that the mitigation of residual stress in weld metal after Weld Inlay repair of reactor vessel In/Outlet nozzle could be possible through UNSM treatment.

Investigation on the Effects of Preventive Maintenance Schemes for Dissimilar Metal Welds on the Residual Stress Distribution (이종금속용접부 예방정비 방법에 따른 잔류응력 분포 고찰)

  • Song, Tae-Kwang;Choi, Young Hwan;Park, Jeong Soon;Chung, Hae-Dong;Oh, Chang-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.1-11
    • /
    • 2011
  • This paper presents the effects of preventive maintenance schemes on the residual stress distributions in dissimilar metal welds. Dissimilar metal weld is known susceptible to PWSCC and thus, effective maintenance schemes to prevent PWSCC are needed. Three preventive maintenances schemes, i.e. weld overlay, MSIP and inlay weld which are widely used in nuclear power plants, are selected and their effects on welding residual stresses are investigated via finite element analyses. As results, weld overlay and MSIP were proved effective method to mitigate residual stresses and inlay weld, on the other hand, produces strong tensile residual stresses in the inner surface. Although Alloy 690 known to be resistant to PWSCC are used in inlay weld, continuous careful observation are needed since tensile welding residual stresses are key parameter for PWSCC.

Issues in Ancient Metal Wire Inlay: A Case Study of Relics from Baekje (고대 금속 선상감 기법의 쟁점과 그 해석 - 백제 선상감 자료를 중심으로 -)

  • Choi, Gieun
    • Conservation Science in Museum
    • /
    • v.20
    • /
    • pp.13-30
    • /
    • 2018
  • Ancient metal objects with inlaid designs were mainly decorated using the wire inlay technique in which "V"- or "U"-shaped grooves were cut in a metal object and then filled with gold or silver. Previous studies on ancient metal objects featuring wire inlay generally attempted to ascertain the inlay techniques applied by examining photomicroscopes acquired during conservation treatment. However, they had limitations when examining wire inlay technique to the minute details. Wire inlay technique can be better investigated by enlarging X-ray films of relics using stereoscopic microscopy under transmitted light. The core processes of the wire inlay technique involve cutting grooves using a chisel and creating the inlay wires, but researchers hold varying opinions about the two processes. This study analyzed the entirety of the materials able to shed light on the main processes applied in Baekje wire inlay by examining X-ray films of relics through stereoscopic microscopy. This exhaustive research revealed that two types of techniques were used for wire inlay during the Baekje period. One is a plastic process of engraving dotted lines using a chisel and is found mostly in objects from the Cheonan and Gongju areas. The other is a cutting process that incises fine lines and was used mostly in relics from the Osan, Seosan, and Wanju areas. It is likely that the Baekje wire inlay techniques feature regional differences because the respective techniques were used or introduced by different groups of people.

A Study on Comparative Analysis of Inlay Craft Technique of Relic in the Three Kingdom Period (삼국시대의 유물에 나타난 입사공예기법 비교분석 연구)

  • Park, Ji-Won;Park, Seung-Chul
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.505-513
    • /
    • 2014
  • Modern metal craft is losing our tradition and personality with simple expressive methods and limited techniques without artistry with the purpose of mass production. In order for development of modern metal craft and to succeed our unique culture, there is a need to consider traditional craft techniques that have been delivered since the ancient. Inlay craft requires high concentration and technology, and it is typical traditional metal craft techniques that show contemporary culture and ideas well. the period of the Three States was the time when inlay technique was introduced the first, and it can be seen in Baekje, Gaya and Silla. Furthermore, when inlay craft is applied for modern metal craft, a possibility was found to grant artistic expression and historical value of our unique artistic expression and historical value. For this purpose, it is expected to establish development of modern metal craft and our unique individuality firmly when continuously seeking practical measures that can accept contemporary crafts and expanding opportunities of education to learn traditional techniques.

Joined in the government-owned handicraft industry during the Joseon Dynasty Job type and role (조선시대 관영수공업에서 입사장(入絲匠)의 직무 유형과 역할)

  • KIM, Serine
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.216-239
    • /
    • 2021
  • Inlay (入絲), a poetic technique of digging grooves in the surface of crafts and decorating them with metal materials, was used throughout the royal daily routines, ceremonies and government officials of the Joseon Dynasty. The government-owned handicraft industry in the Joseon Dynasty was composed of craftsmen belonging to central and local government offices and was operated mainly by government-owned craftsmen. The inlay craftsman was transferred to the central government office and was in charge of inlay poetry for crafts. The current records of Korean inlay craftsmen are concentrated in the state-owned handicraft industry. In the state-owned handicraft industry, the government offices of inlay craftsmen can be divided into Kongjo (工造), Sangeuiwon (尙衣院), and the military. Here the election of a temporary government office for airspace is added. The government offices and military inlay craftsmen who use inlay crafts are assigned, and the inlay craftsmen are placed separately in the temporary office where the fine division of labor is developed. It can be made by utilizing craftsmen. The operation of these production systems was indispensable in pre-modern Korean society, where crafts had to be produced by hand. In this paper, we investigated the roles and job types of craftsmen in the state-owned handicraft industry during the Joseon Dynasty, focusing on inlay craftsmen. Although the details applied to the characteristics and materials of the field, labor supply and demand, etc. are different, Korea pursued crafts for various purposes through craftsmanship within the framework of the basic state-owned handicraft policy . The institutional equipment for implementation was almost common. We believe that adding and analyzing some literature records and relics will help us to study the crafts of the Joseon era in more detail.

Process Development of Laser Cladding for Weld Inlay Repair of Dissimilar Metal Weld in Reactor Vessel In/Outlet Nozzles (원자로 입출구 노즐 이종금속 용접부 Weld Inlay 레이저 클래딩 공정 개발)

  • Cho, Hong Seok;Jung, Kwang Woon;Mo, Min Hwan;Cho, Ki Hyun;Choi, Dong Chul;Lee, Jang Wook;Cho, Sang Beum
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • This study was investigated to develop process technology of laser cladding with austenite stainless steel for Weld Inlay repair of dissimilar metal weld in reactor vessel in/outlet nozzles. Weld Inlay experiments were performed by laser cladding repair system consisting of common manipulator, laser apparatus and welding process scheduler, etc. Single pass welding experiments were conducted in order to obtain the optimum welding process parameters for filler wires of ER309L and Alloy 52M before multi-layer laser cladding. Based on the above obtained results, multi-layer laser cladding experiments were carried out, and welding qualities for weld specimens were estimated by PT, OM, SEM and EDS analysis. Consequently, it was revealed that multi-layer laser cladding on austenite stainless steel using filler wires of ER309L and Alloy 52M could be possible to meet ASME Code standard without any weld defect.

Fiber Reinforced Inlay Adhesion Bridge

  • Cho, Lee-Ra;Yi, Yang-Jin;Song, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.366-374
    • /
    • 2000
  • FRC/ceromer system provides the clinician with a durable, flexible, and esthetic alternative to conventional porcelain fused to metal crowns. FRC is the matrix which is silica-coated and embedded in a resin matrix. The ceromer material which is a second generation indirect composite resin contains silanized, microhybrid inorganic fillers embedded in a light-curing organic matrix. FRC/ceromer restoration has a several advantages: better shock absorption, less wear of occluding teeth, translucency, color stability, bonding ability to dental hard tissues, and resiliency. It has versatility of use including inlay, onlay, single crown, and esthetic veneers. With adhesive technique, it can be used for single tooth replacement in forms of inlay adhesion bridge. In single tooth missing case, conventional PFM bridge has been used for esthetic restoration. However, this restoration has several disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures. Inlay adhesion bridge with FRC/ceromer would be a good alternative treatment plan. This article describes a cases restored with Targis/Vectris inlay adhesion bridge. Tooth preparation guide, fabrication procedure, and cementation procedure of this system will be dealt. The strength/weakness of this restoration will be mentioned, also. If it has been used appropriately in carefully selected case, it can satisfy not only dentist's demand of sparing dental hard tissue but also patient's desire of seeking a esthetic restorations with a natural appearance.

  • PDF

IN VITRO EVALUATION OF FRACTURE RESISTANCE OF VARIOUS THICKNESS FIBER- REINFORCED COMPOSITE INLAY FPD

  • Yi Yang-Jin;Yoon Dong-Jin;Park Chan-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.762-771
    • /
    • 2003
  • Statement of problem. In dentistry, the minimally prepared inlay resin-bonded fixed partial denture (FPD) made of new ceromer / fiber-reinforced composite (FRC) was recently introduced. However, the appropriate dimensions for the long-term success and subsequent failure strength are still unknown. Purpose. The aim of this study was to investigate the most fracture-resistible thickness combination of the ceromer / FRC using a universal testing machine and an AE analyzer. Material and Methods. A metal jig considering the dimensions of premolars and molars was milled and 56-epoxy resin dies, which had a similar elastic modulus to that of dentin, were duplicated. According to manufacturer's instructions, the FRC beams with various thicknesses (2 to 4 mm) were constructed and veneered with the 1 or 2 mm-thick ceromers. The fabricated FPDs were luted with resin cement on the resin dies and stored at room temperature for 72 hours. AE (acoustic emission) sensors were attached to both ends, the specimens were subjected to a compressive load until fracture at a crosshead speed of 0.5 mm/min. The AE and failure loads were recorded and analyzed statistically. Results. The results showed that the failure strength of the ceromer/FRC inlay FPDs was affected by the total thickness of the connectors rather than the ceromer to FRC ratio or the depth of the pulpal wall. Fracture was initiated from the interface and propagated into the ceromer layer regardless of the change in the ceromer / FRC ratio. Conclusion. Within the limitations of this study, the failure loads showed significant differences only in the case of different connector thicknesses, and no significant differences were found between the same connector thickness groups. The application of AE analysis method in a fiber-reinforced inlay FPD can be used to evaluate the fracture behavior and to analyze the precise fracture point.

A study on the machining accuracy of dental digital method focusing on dental inlay

  • Bae, Eun-Jeong;Jeong, Il-Do;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the cutting method and the lamination method to investigate whether the CAD data of the proposed inlay shape are machined correctly. MATERIALS AND METHODS. The Mesial-Occlusal shape of the inlay was modeled by changing the stereolithography (STL). Each group used SLS (metal powder) or SLA (photocurable resin) in the additive method, and wax or zirconia in the subtractive method (n=10 per group, total n=40). Three-dimensional (3D) analysis program (Geomagic Control X inspection software; 3D systems) was used for the alignment and analysis. The root mean square (RMS) in the 2D plane state was measured within $50{\mu}m$ radius of eight comparison measuring points (CMP). Differences were analyzed using one-way analysis of variance and post-hoc Tukey's test were used (${\alpha}=.05$). RESULTS. There was a significant difference in RMS only in SLA and SLS of 2D section (P<.05). In CMP mean, CMP 4 ($-5.3{\pm}46.7{\mu}m$) had a value closest to 0, while CMP 6 ($20.1{\pm}42.4{\mu}m$) and CMP 1 ($-89.2{\pm}61.4{\mu}m$) had the greatest positive value and the greatest negative value, respectively. CONCLUSION. Since the errors obtained from the study do not exceed the clinically acceptable values, the lamination method and the cutting method can be used clinically.

FINITE ELEMENT STRESS ANALYSIS OF A TOOTH RESTORED WITH CAD/CAM CERAMIC INLAY (CAD/CAM 세라믹 인레이로 수복한 치아의 응력분포에 관한 유한요소법적 연구)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.464-484
    • /
    • 2001
  • When restoring a tooth, the dentist tries to choose the ideal material for existing situation. One criterion that is considered is its suitability for restoring coronal strength. As more tooth structure is removed, the cusps are weakened and susceptible to fracture. Further, this increased deformation may cause the formation of intermittent gaps at the margin between the hard tissue and the restoration, facilitating marginal leakage. The improvements in ceramic materials now make it possible for alternatives to amalgams, composites, and cast metal to be of offered for posterior teeth. Of the materials used, ceramics most closely approximates the properties of enamel. The introduction of computer-aided design/computer-aided manufacture(CAD/CAM) systems to restorative dentistry represents a major technological breakthrough. It is possible to design and fabricate ceramic restorations at a single appointment. Additionally, CAD/CAM systems eliminate certain errors and inaccuracies that are inherent to the indirect method and provide an esthetic restoration. The aim of this investigation was to study the loading characteristics of CAD/CAM ceramic inlay and to compare the stress distribution and displacement associated with different designs of cavity(the isthmus width and cavity depth). A human maxillary left first premolar was prepared with standard mesio-occlusal cavity preparation, as recommended by the manufacturer Ceramic inlay was fabricated with CEREC 2 CAD/CIM equipment and cemented into the prepared cavity. Three dimensional model was made by the serial photographic method. The cavity width was varied $\frac{1}{3}$, $\frac{1}{2}$ and $\frac{2}{3}$ of intercuspal distance between buccal and lingual cusp tip. The cavity depth was varied 1.5mm and 2.3mm. So six models were constructed to simulate six conditions. A point load of 500N was applied vertically onto the first node of the lingual slope from the buccal cusp tip. The stress distribution and displacement were solved using ANSYS finite element program(Swanson Analysis System). (omitted)

  • PDF