• Title/Summary/Keyword: Metal bond

Search Result 582, Processing Time 0.034 seconds

EFFECTS OF METAL SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH BETWEEN NI-CR DENTURE BASE AND RELINE RESINS (금속 표면처리방법이 니켈-크롬 합금 의치상과 첨상레진간의 결합강도에 미치는 영향)

  • Kim Young-Il;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • The purpose of this study was to evaluate the effects of four metal surface treatments on the shear bond strength of reline resin to Ni-Cr alloy. The denture base metal used in this study was Ni-Cr alloy(Ticonium Premium 100. Ticonium Co., U.S.A.). 120 specimens were divided into five metal surface treatments: sandblasting only, MR. BOND(Tokuyama Corp.. Japan), Cesead Opaque Primer(Kuraray Co., Japan), METALPRIMER II(GC Corp., Japan) and Super-Bond C&B(Sun Medical Co., Japan) after sandblasting. They were bonded with one of three reline resins Mild Rebaron(GC Corp., Japan), Mild Rebaron LC(GC Corp., Japan) and Meta Base M(Sun Medical Co., Japan). Then they were thermocycled 1,000 times at temperature of $4^{\circ}C$ and $60^{\circ}C$. The shear bond strengths were measured using the universal testing machine(Instron, Model 4301, England) with a cross-head speed of 2 mm/min. The results were as follows : 1. All metal primers and adhesive cement significantly improved the bond strength of reline resin to Ni-Cr alloy compared with sandblasted specimens. 2. In Mild Rebaron and Mild Rebaron LC. Cesead Opaque Primer showed the highest bond strength, but the differences among Cesead Opaque Primer, MR. BOND and METALPRIMER II were not significant. The bond strength of Cesead Opaque Primer was significantly different with that of Super-Bond C&B. 3. In Meta Base M, Super-Bond C&B showed the highest bond strength, but there was no difference between Super-Bond C&B and three metal primers. 4. There was no difference in the bond strength between Mild Rebaron and Mild Rebaron LC when metal surface was treated with the same method. 5. The bond strengths of Mild Rebaron and Mild Rebaron LC treated with Cesead Opaque Primer were higher than that of Meta Base M. The bond strengths of Mild Rebaron treated with MR. BOND and METALPRIMER II was higher than that of Meta Base M, However, there was no difference among three reline resins treated with Super-Bond C&B.

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

THE EFFECT OF SIZE AND SHAPE OF RETENTION ELEMENT ON COMPOSITE TO METAL BOND STRENGTH (유지요소의 크기와 형태가 간접복합레진과 금속간의 결합강도에 미치는 영향)

  • Lee, Yun-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.665-674
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the effect of sire and shape of retention element on the bond strength of indirect composite resin and metal. Material and method: The metal disk specimens, each 6mm in diameter, were cast from CrCo alloy. They were divided into 8 groups by applied retention element. retention bead group $B2\;({\phi}\;0.2mm),\;B4\;({\phi}\;0.4mm),\;B6\;({\phi}\;0.6mm),\;B8\;({\phi}\;0.8mm)$, retention crystal group C2 (0.2mm), C5 (0.5mm), C8 (0.8mm) and sandblasting group SB ($110{\mu}m\;Al_2O_3$ blasting) as control. Eighty-eight metal specimens were veneered with $TESCERA^{(R)}$ Indirect resin system. One specimen of each group was sectioned and the resin-metal bonding pattern at the interface was observed under measuring microscope. Other specimens were then tested for tensile bond strength on an Instron universal testing machine at a crosshead speed of 2mm/min. Results: 1. Compared to sandblasting, beads or crystals increased the resin-metal bond strength (P<.05). 2. 0.2mm retention crystals were most effective in improving the resin-metal bond strength (P>.05). 3. 0.2mm beads showed the highest bond strength among retention bead groups, but there was no statistically significant difference (P>.05). 4. Retention crystals tend to be higher in bond strength than retention beads due to wider surface area. 5. The larger retention element, the larger the undercut for the mechanical retention, but the gap at resin-metal interface was also increased. Conclusion: Within the limitations of this study, 0.2mm retention crystals were most effective in improving the resin-metal bond strength.

Theoretical Study of C-H σ-Bond Activation and Related Reactions

  • Sakaki, Shigeyoshi
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.6
    • /
    • pp.829-831
    • /
    • 2003
  • Various theoretical studies of σ-bond activation of organic molecules by transition metal complexes arereviewed. In the homolytic σ-bond activation, the d orbital energy level of the central metal is an importantfactor, as well known. At the same time, the electron-withdrawing substituent which stabilizes the sp3 orbitalaccelerates the homolytic σ-bond activation. In the heterolytic C-H σ-bond activation of RH by $MXL_n$, the XHbond formation is an important driving force, where $MRL_n$ and HX are formed as products. The heterolytic σ-bond activation is also understood in terms of the electrophilic attack of the metal center to the substrate.

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

Mo-Mn Metallizing on Sintered Alumina and It합s Bond Strength (소결 알루미나의 금속접합 및 접합강도에 관한 연구)

  • Lee, Joon;Kim, Young-Tai;Jang, Sung-Do;Son, Yong-Bae
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.6
    • /
    • pp.58-70
    • /
    • 1985
  • The bond strength of metal to ceramic sealing in Mo-Mn metallizing was investigated by examining the effects of flux composition in alumina ceramics particle size of molybdenum metal powder wet hydrogen atmosphere and temperature in metallizing. The maximum bond strength was obtained when the glass phase filled almost all the microstructural cavities around the interfacial area with few micropores. Such a favorable microstrcutre waas formed and maximum bond strength was observed between 130$0^{\circ}C$. Also the metal to ceramic bond strength was increased using finer molybdenum metal powder than coarse powder. When content of $SiO_2$ in the flux of alumina ceramics was constant metal to ceramic bond strength was improved with increasing the ratio of CaO to MgO in the flux.

  • PDF

A STUDY OF THE SHEAR BOND STRENGTH OF METAL BRACKETS AND CERAMIC BRACKETS AND THE CONDITION AFTER DEBONDING (Metal bracket과 ceramic bracket의 전단 결합 강도와 debonding 상태에 관한 연구)

  • Yoon, Jung-Jin;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.22 no.2 s.37
    • /
    • pp.327-343
    • /
    • 1992
  • Metal brackets and ceramic brackets were bonded to natural teeth, porcelain crowns and gold crowns After stored in artificial saliva solution for 72 hours at $37^{\circ}C$, the shear bond strengths were measured by Instron and compared with them, the bonding sites and bracket bases were examined by scanning electron microscope and light optical stereomicroscope. The results were as follows: 1. The shear bond strengths of the group which metal brackets were bonded to natural teeth and the groups which ceramic brackets were bonded to natural teeth and porcelain crowns were comparable to each other, the shear bond strength of the group which metal brackets were bonded to gold crowns was significantly low. 2. The bond failed predominantly at the bracket base/adhesive interface with the bulk of adhesive remaining on enamel in the group which metal brackets were bonded to natural teeth. 3. The bond failed consistently at the crown/adhesive interface with all of adhesive remaining on the bracket babes in the group which metal brackets were bonded to gold crowns. 4. The bond failed at the enamel or crown/adhesive interface with the bulk of adhesive remaining on the bracket bases in the groups which cramic brackets were bonded to natural teeth and porcelain crowns. 5. The shear bond strengths of the groups which ceramic brackets were bonded to porcelain crowns were not affected by etching time.

  • PDF

Shear bond strength in bilayer metal-heat pressed glass ceramic structure (열가압 방식의 금속-유리도재 이중 구조물의 전단결합강도에 대한 연구)

  • Lee, Kyungeun;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.101-107
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the shear bond strength of the metal-heat pressed glass ceramic bilayer structure. Methods: Metal framework specimens were prepared and surface is spreaded opaque(IPS InLine system opaque, IvoclarVivadent, Liechtenstein). There were 10 specimens for each bilayer dental ceramic group. The first group was porcelain fused metal, Press on metal IPS Inline press group, and press on metal HASS prototype group. Specimens measured for the shear bond strength on Schwickerath test by Instron universal testing machine(Instron3345, Instron Corp., USA). Mean average bond strength values of each specimen group were analyzed using a one-way ANOVA analysis of variance Saphiro-wilk's test. Statistical analysis were performed using IBM SPSS 23.0(IBM Co., Armonk, USA) Results: $RMS{\pm}SD$ The highest mean average HASS POM showed a bond strength value ($47.55{\pm}12.80Mpa$). The lowest mean average values Porcelain fused metal ($33.30{\pm}2.00Mpa$). Independent t-test was conduct to analysis the significant difference (p<0.05) (Table 3). Conclusion: Three kinds of Metal/ glass bilayer dental ceramics bond strength were clinical acceptability. Especially, as lithium disilicate containing represents higher bond strength.

An Experimental study on the bond strength according to the surface treatment of metal alloy for porcelain fused metal crown (-금속(金屬) 표면처리방법(表面處理方法)에 따른 비귀금속합금(非貴金屬合金)과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 실험적(實驗的) 연구(硏究)-)

  • Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.83-88
    • /
    • 1989
  • This investigation was performed to evaluate the effect of four different preteatment techniques on the bond strength of porcelain to non-precious metal alloy. Samples of total of 40 were divided into 4 groups according to the 4 variables which included the 50$\mu$alumina oxide air abrasion, method, the as retention bead method, the L-retention bead method, the Etching method. The completed metal-porcelain samples were compressed in Instron loading machine until gross fracture occured to examine the effect of the complex variables on the bond strength of porcelain to non precious metal alloy. The result obtained were as follows : 1. The difference of bond strength according to four different pretreatment techniques was statistically significant(p<0.01). 2. The difference of bond strength between the ss-retention bead method and the L-retention bead method was not significant statistically(p>0.05) 3. The difference of bond strength between the retention bead method and the etching method was statistically significant(p<0.01). 4. The difference of bond strength between the retention bead method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01). 5. The difference of bond strength between the etching method and the 50$\mu$alumina oxide air abrasion method was statistically significant(p<0.01).

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH BETWEEN NONPRECIOUS METAL SURFACE AND RESIN CEMENT ACCORDING TO THE VARIOUS SURFACE TREATMENT METHODS (다양한 표면 처리 방법에 따른 비귀금속과 접착성 레진간의 결합력에 관한 연구)

  • Ryu Young-Ryeol;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.157-170
    • /
    • 2001
  • The bond strength is the most important factor in establishing long-term success of resin-retained fixed prostheses. So, various surface treatment methods have been introduced to improve the bond strength of metal surface and bonding resin till now This study was performed to compare the effect of silicoating with that of metal primer and analyze the correlation between treatment time of sandblasting and the bond strength, so that meant to find more effective surface treatment method that could enhance the bond strength of resin-retained fixed prostheses. The surfaces of all specimens made of $Verabond^{(R)}$ alloys were air abraded with $250{\mu}m\;Al_2O_3$ according to treatment time of sandblasting and they were subdivided to be treated with only sandblasting(S group), silicoating following sandblasting(SS group) and metal primer application after sandblasting(SM group). Then pairs of metal specimens (${\phi}10mm{\times}h\;2mm,\;{\phi}6{\times}h\;2mm$) were bonded with Super bond $C&B^{(R)}$. The specimens were stored in $38^{\circ}C$ water for 48 hours and shear bond strength was measured using the universal testing machine. The results were as follows, 1. In the comparison of shear bond strength according to treatment time of sandblasting, bond strength was increased in the order of 0', 15', 30', 45', 60' group. 0' group had significantly lower value than any other, while 0', 15' group were significantly different with 30', 45', 60' group(p<0.05). 2. In the comparison of shear bond strength according surface treatment methods, bond strength was increased in the order of S group. SS group and SM group. S group was significantly different with SS group and SM group(p<0.05). 3. Observing the mode of bond failure. 0', 15' group showed only adhesive failure, and 30', 45', 60' group did mostly adhesive & cohesive failure in S group. In SS group and SM group, all other groups except 0', 15' group showed mostly cohesive failure. From the above results, it is considered that sandblasting should be treated for more than 30 seconds, and metal primer be more effective and available clinically than silicoater system which is complicate, technique-sensitive and time-consuming method, when nonprecious metal surface is planning be treated with in order enhance the bond strength of resin-retained fixed prostheses.

  • PDF