• Title/Summary/Keyword: Metal Industry Wastewater

Search Result 32, Processing Time 0.027 seconds

Life Cycle Environmental Analysis of Valuable Metal (Ag) Recovery Process in Plating Waste Water (폐도금액내 유가금속(Ag) 회수 공정에 대한 전과정 환경성 분석)

  • Da Yeon Kim;Seong You Lee;Yong Woo Hwang;Taek Kwan Kwon
    • Resources Recycling
    • /
    • v.32 no.2
    • /
    • pp.12-18
    • /
    • 2023
  • In 2018, the demand for silver (referred to as Ag) in the electrical and electronics sector was 249 million tons. The demand stood at 81 million tons in the solar module production sector. Currently, due to the rapid increase in solar module installation, the demand for silver is increasing drastically in Korea. However, Korea's natural metal resources and reserves are insufficient in comparison to their consumption, and the domestic silver ore self-sufficiency rate was as low as 2.2% as of 2021. This implies that a recycling technology is necessary to recover valuable metal resources contained in the waste plating solution generated in the metal industry. Therefore, this study compared and analyzed, the results of the impact evaluation through life cycle assessment according to an improvement in the process of recovery of valuable metals in the waste plating solution. The process improvement resulted in reducing GWP (Global Warming Potential) and ADP(Abiotic Depletion Potential) by 50% and 67%, respectively. The GWP of electricity and industrial water was reduced by 98% and 93%, respectively, which significantly contributed to the minimization of energy and water consumption. Thus, the improvement in recycling technology has a high potential to reduce chemical and energy use and improve resource productivity in the urban mining industry.

Assessment of Technology-Based Industrial Wastewater Effluent Limitations and Standards for the Application in Domestic Industries ( I ) : Case-study, Applying TBELs in US (처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구( I ) : 미국 TBELs 적용사례 검토)

  • Kim, Kyeongjin;Son, Daehee;Her, Jin;Kim, Kwangin;Kwon, Osang;Yeom, Ictae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Technology-Based Effluent Limitations (TBELs) is a permit limits for a pollutant that is based on the capability of a treatment technology to reduce the pollutant to a certain concentration. Widely practiced for regulations of industrial wastewater in US, TBELs has been accepted as an effective means that can achieve balanced goals between complete elimination of pollutants discharge and economic feasibility for industries. The review of TBELs application in US and the applicability of TBELs to the domestic industry categories was given in three papers. In the first paper, the development and practices of TBELs in US were reviewed including case studies. The developments of TBELs in US in the four major categories, the metal products & machinery, the petroleum refining, the porcelain enameling and the meat & poultry products were reviewed. The applicability of TBELs to the domestic industrial categories was also assessed. In the second paper, the pollution loads analysis for domestic industrial wastewater was conducted based on risk assessment indicator using Toxic Weighting Factors (TWFs). This is an essential part to determine the priority of TBELs application for the domestic industrial categories. In the last paper, the application of TBELs to the domestic industries was demonstrated through a case-study for the pulp/paper/paperboard category. Direct application of TBELs of US into the Korean regulation system may not be desirable because the specific goals and the environment for the regulations for the two countries may not be identical. For example, unlike US, Korea does not adopt the individual permit system for pollution sources. However, among the unproductive and exhaustive controversies over the uniform regulations regardless of the industrial categories in Korea, the introduction of the principles of TBELs are inevitable and more extensive study for applications of TBELs optimized for Korean regulation system will be necessary.

Removal of Heavy Metals from Wastewater Using Steelmaking Slag and Sludge (제강 슬래그 및 분진에 의한 폐수 중 중금속 제거)

  • Hyun, Jae-Hyuk;Kim, Min-Gil;Nam, In-Young;Baek, Jung-Sun
    • Resources Recycling
    • /
    • v.8 no.1
    • /
    • pp.11-17
    • /
    • 1999
  • This study was carried out to investigate the efficiency of stcclmaldng slag and sludge in removing metals existing in wastewater or leachate. Laboratory experiments were performed as a function of initial concentration of metals. pH a and temperature of the background solution and the presence of che1ating agent, EDTA. The test conditions were temperatures r ranging from $25^{\circ}C$ to $50^{\circ}C$; initial concentrations varying from 5mg/L to 50 mg/L; pH between 3 and 11; and Cu. Cd‘ and Pb a as adsorbates. The results of tests showed that overall rates of metals removal were 20~30% at pH 3 and greater than 90% at p pH 7 and 11. Metals were removed from the solution predominantly via adsorption in acidic conditions, and the combined e effects of adsorption and precipitation in neutral and alkaline conditions. In view of the test results and other engineering c characteristics of steelmaking slag and sludg$\xi$, these industrial by-products from steel industry have a high potential to be used l in wastewater treatment and are particularly beneficial when used as landfill liner additives due to thelJ ability to remove heavy m metals from leachate.

  • PDF

Comparative Study on Recovery of Nickel by Ion Exchange and Electrodialysis (이온교환과 전기투석을 이용한 니켈회수의 비교연구)

  • Sim, Joo-Hyun;Seo, Hyung-Joon;Seo, Jae-Hee;Kim, Dae-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.640-647
    • /
    • 2006
  • It is difficult to treat wastewater involved in heavy metal in electroplating industry. Recently, many industries adopt the clean technology to prevent production of pollutant in the process or reuse after the appropriate pollutant treatment. In this study, we estimate the ability of recovery of nickel and the efficiency using lab-scale ion exchange and electrodialysis process with electroplating industry wastewater. In the ion exchange experiments with 5 types of resin, the result showed that S 1467(gel-type strong acidic cation exchange resin) has the highest exchange capacity. And it showed that the 4 N HCl has the highest in regeneration efficiency and maximum concentration in the regeneration experiments with various kinds md concentration of the regenerant. During the electrodialysis experiments, we varied the current density, the concentration of electrode rinse solution, the flow rate of concentrate and electrode rinse solution in order to find the optimum operating condition. As a result, we obtained $250A/m^2$ of current density, 2 N $H_2SO_4$ of concentration of electrode rinse solution, 30 mL/min of flow rate of concentrate and electrode rinse solution as the best operating conditions. We performed the scale-up experiments on the basis of ion exchange and electrodialysis experiments. And we obtained the experimental result that exchange capacity of S 1467 was 1.88 eq/L resin, and regeneration efficiency was 93.7% in the ion exchange scale-up experiment, we also got the result that concentration and dilution efficiency increased, and current efficiency kept constant in the scale-up experiments.

Characteristics of Heavy Metal Removal from Aqueous Solutions using Leather Industry by-products (피혁산업 부산물에 의한 용존 중금속 제거 특성)

  • Kim, Keun-Han;Lee, Nam-Hee;Paik, In-Kyu;Park, Jae-Hyung;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.417-426
    • /
    • 2010
  • In this study, ten different bio-adsorbents were prepared by immobilization of vegetable tannins such as mimosa(Catechol Tannin) and chestnut(Pyrogallol Tannin) on the collagen matrix which was derived from during leather manufacturing processing. Removal efficiency of Cu(II), Cd(II), Zn(II), Pb(II), Cr(III) by each bio-adsorbent in synthetic wastewater was evaluated by a laboratory-scale batch reactor at different reaction conditions. When mimosa was used as a vegetable tannin, the penetration efficiency of mimosa into the inner bundle of fiber depended on the dose of the naphthalene condensated penetrant; 3% ${\geq}$ 1.5% > 0%. For all bio-adsorbents, removal of heavy metal ions was not observed below pH 3.0 but was rapidly increased between pH 3.0 and 6.0, showing near complete removal of all heavy metal ions except Zn(II) above pH 6.0. Removal of Cr(III) was quite similar for all bio-adsorbents while removal of Cu(II), Zn(II) and Pb(II) was higher by bio-adsorbents immobilized with chestnut than that by mimosa. Adsorption of Pb(II) and Cu(II) by S10 bio-adsorbent was little affected by the presence of monovalent and divalent electrolytes as well as variation of 1000 times ionic concentration with $NaNO_3$.

Characteristics of a Novel Acinetobacter sp. and Its Kinetics in Hexavalent Chromium Bioreduction

  • M., Narayani;K., Vidya Shetty
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.5
    • /
    • pp.690-698
    • /
    • 2012
  • Cr-B2, a Gram-negative hexavalent chromium [Cr(VI)] reducing bacteria, was isolated from the aerator water of an activated sludge process in the wastewater treatment facility of a dye and pigment based chemical industry. Cr-B2 exhibited a resistance for 1,100 mg/l Cr(VI) and, similarly, resistance against other heavy metal ions such as $Ni^{2+}$ (800 mg/l), $Cu^{2+}$ (600 mg/l), $Pb^{2+}$ (1,100 mg/l), $Cd^{2+}$ (350 mg/l), $ZN^{2+}$ (700 mg/l), and $Fe^{3+}$ (1,000 mg/l), and against selected antibiotics. Cr-B2 was observed to efficiently reduce 200 mg/l Cr(VI) completely in both nutrient and LB media, and could convert Cr(VI) to Cr(III) aerobically. Cr(VI) reduction kinetics followed allosteric enzyme kinetics. The $K_m$ values were found to be 43.11 mg/l for nutrient media and 38.05 mg/l for LB media. $V_{max}$ values of 13.17 mg/l/h and 12.53 mg/l/h were obtained for nutrient media and LB media, respectively, and the cooperativity coefficients (n) were found to be 8.47 and 3.49, respectively, indicating positive cooperativity in both cases. SEM analysis showed the formation of wrinkles and depressions in the cells when exposed to 800 mg/l Cr(VI) concentration. The organism was seen to exhibit pleomorphic behavior. Cr-B2 was identified on the basis of morphological, biochemical, and partial 16S rRNA gene sequencing chracterizations and found to be Acinetobacter sp.

Basic study and patent analysis of electrochemical denitrification from industrial wastewater (산업폐수(産業廢水)로부터 전해처리(電解處理)에 의한 탈질(脫窒) 연구(硏究) 및 특허(特許) 분석(分析))

  • Lee, Churl-Kyoung
    • Resources Recycling
    • /
    • v.16 no.6
    • /
    • pp.52-60
    • /
    • 2007
  • Denitrification from aqueous solution was investigated through patent analysis and electrochemical denitrification experiment. Among several candidates, biological treatment and oxidation/reduction method are mainly discussed. Recently, patent pending concerning to electrochemical treatment is increasing. Based on basic electrochemical study, total nitrogen was removed up 47% by 1-hour galvanostatic electrolysis with Fe cathode and Pt anode. More applicable technique to industry could be mentioned combination of two or more technologies suitable to waste water characteristics. In the case of small and concentrate effluent, combination of chemical and electrochemical treatment would be recommendable because nitrate could be easily converted to nitrite by chemical treatment, and in that case denitrification by electrolysis becomes more efficient and metal ions from chemical treatment can be recovered during electrolysis.

Pollutants Characteristics of Surface Runoff from the Industrial Complex (산업공단에서의 지표유출수 오염물질 특성)

  • Kim, Youn-Kwon;Shin, Eung-Bai;Lee, Doo-Jin;Pae, Yo-sop;Yoon, Hyun-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.689-698
    • /
    • 2000
  • The quality of stormwater runoff has been a major concern in water quality preservation. Characteristics of heavy metals and conventional pollutants in surface runoff from industrial complex, during the first flush, were not completely understood, Generally, separated sewer system is known for their water quality with untreated wastewater during storm events. In this study, the quality and characteristics of surface runoff from the industrial complex were investigated. The target area in the industrial complex catchment was divided 4 sub-areas, and the quality of stormwater runoff from the selected drainage areas was investigated using a grab sampling method. The petro-chemical industry and the junkyard discharged relatively high concentration of conventional pollutants, such as BOD, COD, SS, and TN through the first flush runoff samples. On the other hand, a higher level of heavy metals was found in the first flush runoff from the metal-mechanical industry and the scrap storage yard. For metals, Fe, Zn and Cu were the most prevalent species found in the first flush runoff from all sites for every surface runoff samples, while Pb, As, Cd, Cr and Ni were the least prevalent species and Hg was not found in any sample at any site. These results suggest that the nature of pollutants in surface runoff from the industrial complex was related to the type of industry, and the concentration of pollutants was determinated by the degree of exposed pollutant sources and the characteristic of rainfall events at the sites.

  • PDF

Study on characteristics of specific hazardous substances in the industrial wastewater effluent (사업장 방류수 중 특정수질유해물질 배출 특성 연구)

  • Kim, Seungho;Choi, Youngseop;Kim, Yunhee;Kim, Jongmin;Chang, Gilsik;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.114-125
    • /
    • 2016
  • In this study, 165 wastewater discharge facilities in 10 business types were investigated with regard to 24 specific hazardous substances that included heavy metals, VOCs, CN, and phenol in the Gwangju city. Cu in the range from from 0.008 to 35.420 mg/L was detected in all business types and the detection rate was 46.8 %. Other heavy metals, such as Cd, As, Hg, Pb, and Cr+6 were detected as well. However, their detection rates ranged between 0.6 and 1.8 %. CN and phenol were detected in one and five facilities, respectively. 12 species of VOCs were detected: chloroform 80.6 % (0.42 to 81.60 μg/L), benzene 16.4 % (1.49 to 3.31 μg/L), trichloroethylene 11.5 % (1.78 to 6.02 μg/L), 1,1-dichloroethylene 10.3 % (1.23 to 5.89 μg/L), and dichloromethane 8.5 % (0.28 to 968.86 μg/L) in the detection rate order. The concentration of VOCs was detected in trace amounts, except for dichloromethane that exceeded the effluent quality standard in three business types, namely, metal manufacturing, food industry, and car washing facility. Chloroform was detected in all business types, where 24.88 μg/L were detected in the laundry business and 53.41 μg/L in the water supply business; the mean concentration of chloroform in these two business types was higher than elsewhere. Therefore, for the disposal of non-degradable specific hazardous substances in industrial wastewater, it is necessary to introduce physical and chemical processes, such as activated carbon adsorption, fenton oxidation, ozone treatment, as well as photocatalyst and the UV radiation.

Impact Assessment of River Water Quality using Organic Pollutant Index - Industrial Waste Water - (유기물오염도 지표를 이용한 하천수질영향평가 - 산업폐수의 방류수질을 기준으로 -)

  • Jo, Soo-Hyun;Kang, Mee-A;Choo, Yang-Yeop;Jeong, Gyo-Cheol;Jung, Dong-Hee;Yi, Jun-Heung
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.373-379
    • /
    • 2006
  • We investigated the relationship of the organic pollutant index in wastewater where the high percentages of an organic load to a water body was found. Measuring of TOC was to identify the relationship with COD and BOD which were used already. The correlation coefficient (r) of TOC/COD, BOD/COD and TOC/BOD were effected by the types of industry such as paper, textile, chemical, food and metal industries. In food industry it was found that the highest correlation coefficient (r) of TOC/COD, BOD/COD and TOC/BOD as 0.967, 0.969 and 0.990, respectively. There is low correlation coefficient in many cases. Hence it was impossible that the use of TOC for the water standard or monitoring instead of COD and BOD directly. However it can be used as alternative index to management a water process in the case of waste water where there was found high correlation coefficient of TOC/ COD, BOD/COD and TOC/BOD. It was sure that the water quality of river body can be protected if we use these the relationship among organic index.