• Title/Summary/Keyword: Metal Filter

Search Result 347, Processing Time 0.046 seconds

Preparation of Metal/Ceramic Composite Ultrafiltration Hollow Fiber Membranes (금속/세라믹 중공사형 복합 한외여과막의 제조)

  • Kim, In-Chul;Jeong, Bo-Reum;Lee, Dong-Wook;Park, Joo-Young;Kwon, Ja-Young;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • The aim of this paper is to prepare metal/ceramic composite ultrafiltration membranes by coating inorganic particles on a metallic hollow fiber filter. The diameter and the pore size of the filter was 2.0 mm and $2{\sim}8{\mu}m$. The metal/ceramic composite ultrafiltration membranes were obtained by a coating process of silica and titania sols on top of the metallic filter. For this purpose the method of fast freeze drying and dip-coating were used. It was found that the pore size of the membrane was about 50 nm from SEM and PMI characterization. The pore size was controlled by changing the size of the particles, sintering period and temperature.

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.

Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes (외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

Miniaturization Technology of the Filter for High-speed Wireless Communication Systems (초고속 무선통신 설비용 필터의 소형화에 관한 연구)

  • Hwang, Jae-Ho;Moon, Jun-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.368-371
    • /
    • 2005
  • In this paper, a small band pass filter is designed using new probe type for wireless communication system. In order to provide a band pass filter which can be reduced in dimension, can be reduced in height, and can be surface-mounted. The filter was fabricated using $TE_{01{\delta}}$ mode dielectric resonator. The input/output probes are attached to coner portion of the rectangular metal cavity. Results of the manufactured filter$(12{\times}12{\times}8mm)$ show that the center frequency is 9.953GHz, the insertion loss is -2.98 dB, the 3dB-bandwidth is 15 MHz, and the lode Q is 663.

  • PDF

Failure Analysis of RF SAW Filter by High Temperature Storage Test (고온저장시험에 의한 RF SAW Filter의 고장분석)

  • Kim, Young-Goo;Kim, Tae-Hong;You, Jong-Jun
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.140-144
    • /
    • 2003
  • To investigate failure analysis of surface acoustic wave (SAW) filter for radio frequency, high temperature storage test was carried out. The failure criteria were insertion loss at passband and rejection level at stopband. As a result, the insertion loss at passband increase about 4 dB was due to damages of interdigital transducer (IDT). That is caused by poor adhesion between metal electrode(AI) and piezoelectric substrate and defects on a manufacturing process. This result indicates that good adhesion between electrode and ceramic substrate is important factor And also we investigated the demage factors of electrode. Screen possible of saw filter using high temperature storage test(HTOL) in the manufacturing phase be presented.

  • PDF

Fabrication of Infrared Filters for Three-Dimensional CMOS Image Sensor Applications

  • Lee, Myung Bok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.341-344
    • /
    • 2017
  • Infrared (IR) filters were developed to implement integrated three-dimensional (3D) image sensors that are capable of obtaining both color image and depth information at the same time. The combination of light filters applicable to the 3D image sensor is composed of a modified IR cut filter mounted on the objective lens module and on-chip filters such as IR pass filters and color filters. The IR cut filters were fabricated by inorganic $SiO_2/TiO_2$ multilayered thin-film deposition using RF magnetron sputtering. On-chip IR pass filters were synthetized by dissolving various pigments and dyes in organic solvents and by subsequent patterning with photolithography. The fabrication process of the filters is fairly compatible with the complementary metal oxide semiconductor (CMOS) process. Thus, the IR cut filter and IR pass filter combined with conventional color filters are considered successfully applicable to 3D image sensors.

Development of CMOS Sigma-Delta DAC Chip for Using ADSL Modem (ADSL 모뎀용 CMOS 시그마-델타 DAC 칩 개발)

  • Bang, Jun-Ho;Kim, Sun-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.4
    • /
    • pp.148-153
    • /
    • 2003
  • In this paper, the low voltage 3V Sigma-Delta Digital Analog Converter(DAC) is designed for using in the transmitter of ADSL analog front-end. We have developed the CMOS DAC according to ANSI T1.413-2(DMT) standard specifications of the chip. The designed 4th-order DAC is composed of three block which are 1-bit DAC, 1st-order Switched-Capacitor filter and analog active 2nd-order Resistor-Capacitor(RC) filter. The HSPICE simulation of the designed DAC showing 65db SNR, is connected with 1.1MHz continuous lowpass filter. And also, we have performed the circuits verification and layout verification(ERC, DRC, LVS) followed by fabrication using TSMC 2-poly 5-metal p-substrate CMOS $0.35{\mu}m$ processing parameter. Finally, the chip testing has been performed and presented in the results.

Sintered $Fe_3Al$ Intermetallic - A New Filter Element for Hot Gas Filtration

  • Xing, Y.;Kuang, X.;Wang, F.;Kuang, C.;Fang, Y.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.597-598
    • /
    • 2006
  • Gas filtration at high temperature from industrial processes offers various advantages such as increasing process efficiency, improving heat recovery and materials resource recovery, etc. At the same time, it is an advanced environment protection technology. This paper describes a newly developed metallic filter element. The manufacturing process of sintered $Fe_3Al$ metallic powder and the mechanical and filtration characteristics of this filter element were investigated. In this work, the phase constituent changes of the $Fe_3Al$ powder during sintering were studied. The newly developed filter elements were found to have excellent corrosion resistance, good thermal resistance, high strength and high filtration efficiency.

  • PDF

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.