• Title/Summary/Keyword: Mesh electrode

Search Result 138, Processing Time 0.025 seconds

Synthesis of Dye-sensitized Solar Cells with Titanium Mesh Electrode (티타늄 메쉬 전극구조를 이용한 염료 태양전지 제작)

  • Paeng, Sung-Hwan;Kim, Doo-Hwan;Park, Min-Woo;Sung, Youl-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2436-2440
    • /
    • 2009
  • In this work, TCO-less dye-sensitized solar cells (DSCs) using Ti-mesh layer is fabricated for high-efficient low-cost solar cell application. The Ti-mesh metal can replace TCO in the photo-electrode part of DSCs, thus the cell structure is composed of a glass/dye sensitized TiO2 particle/ Ti-mesh layer/electrolyte/Pt sputtered counter electrode/ glass. The Ti-mesh electrode with high conductivity can collect electrons from the $TiO_2$ layer and allows the ionic diffusion of $I^-/I_3^-$ through the mesh hole. Thin Ti-mesh ($\sim40{\mu}m$ in thickness) electrode material is processed using rapid prototype method. The efficiency of prepared TCO-less DSCs sample is about 1.45 % ((ff: 0.5, Voc: 0.52V, Jsc: 5.55 $mA/cm^2$).

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

The Characterization of Electrolytic Ion Water Generator by Electrode (전극에 따른 전해 이온수 발생장치의 특성)

  • Han, Byung-Jo;Lee, Yeon;Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1786-1791
    • /
    • 2016
  • The damage has occurred inside the semiconductor pattern When using conventional wet station for semiconductor. It was used for electrolytic ion water generator in order to prevent damage to the semiconductor pattern. It was designed and developed a flow path electrode and the mesh electrode to check the efficiency of the electrode. And It confirmed the expected results through the simulation of the flow path. and ORP were measured in accordance with the current and voltage of mesh electrode and flow paht electrodes. Flow path electrode 22A is 3V, up to pH 9.8, the value of ORP-558mV was measured and the mesh electrode was measured up to pH 9.8, ORP -350mV.

Synthesis of TCO-Iess Dye Sensitized Solar Cell (TCO-Iess 구조 염료 태양전지의 제작과 광전변환 특성)

  • Heo, Jong-Hyun;Park, Sun-Hee;Kwak, Dong-Joo;Sung, YouI-Moon;Song, Jae-Eun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.251-254
    • /
    • 2009
  • A new type of dye-sensitized solar cells(DSCs) based on Ti-mesh electrode without using TCO layer is fabricated for high-efficient and low-cost solar cell application. The TCO-Iess DSCs sample is composed of a [glass/ dye sensitized $TiO_2$ layer/ Ti-mesh electrode/ electrolyte/ metal counter electrode]. The Ti-mesh electrode with high conductivity can collect electrons from the $TiO_2$ layer and allows the ionic diffusion of $I^-/I_3{^-}$ through the mesh hole. Thin Ti-mesh (${\sim}40{\mu}m$ in thickness) electrode material is processed using rapid prototype method. Electrical performance of as-fabricated DSCs is presented and discussed in detail.

  • PDF

Synthesis of TCO-less Dye Sensitized Solar Cells (TCO-less 염료태양전지 제작)

  • Heo, Jong-Hyun;Kwak, Dong-Joo;Sung, Youl-Moon;Kim, Tae-Heung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1074_1075
    • /
    • 2009
  • A new type of dye-sensitized solar cells(DSCs) based on Ti-mesh electrode without using TCO layer is fabricated for high-efficient low-cost solar cell application. The TCO-less DSCs sample is composed of a [glass/ dye sensitized $TiO_2$ layer/ Ti-mesh electrode/ electrolyte/ metal counter electrode]. The Ti-mesh electrode with high conductivity can collect electrons from the $TiO_2$ layer and allows the ionic diffusion of $I^-/I_3^-$ through the mesh hole. Thin Ti-mesh ($\sim40{\mu}m$ in thickness) electrode material is processed using rapid prototype method. Electrical performance of as-fabricated DSCs is presented and discussed in detail.

  • PDF

A study on the characteristic of Dye-sensitized solar cell with mesh structure of counter electrode (Mesh구조의 상대전극을 갖는 염료감응형태양전지의 특성연구)

  • Jang, Jin-Ju;Seo, Hyun-Woong;Son, Min-Kyu;Lee, Kyoung-Jun;Hong, Ji-Tae;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.131-133
    • /
    • 2008
  • A serious problem of the 21st century is the supply of energy resources. Reserves of fossil fuels are facing depletion: renewable energy resources must be developed in this era. Dye sensitized solar cell (DSC) has been very economical and easy method to convert solar energy to electricity. Recently a novel tandem cell structure is proposed to improve photocurrent of DSC. To fabricated a tandem cell, the mesh structure of counter electrode is essential for the improvement in transmittance. In this study, we conducted the experiment to get the characteristic of DSC with mesh counter electrode. Under the standard test condition (AM 1.5, 100mW/$cm^2$), we obtained the maximum efficiency of 3.41% and the transmittance of 72% in the DSC with mesh counter electrode.

  • PDF

Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration (방전공격과 방전극 형상이 오존발생농도에 미치는 영향)

  • Park, Seung-Lok;Lee, Jae-Chan;Jung, Sung-Jin;Moon, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

Presumption for Reduced Scale Model of Mesh Electrod (망상접지전극의 축척모델에 관한 추정)

  • Koh, Hee-Seog;Kim, Ju-Chan;Kim, Sung-Sam;Lee, Chung-Sik;Choi, Jong-Kyu;Ryoo, Hee-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.330-332
    • /
    • 2002
  • There are a lot errors and little accuracy when calculating the grounding resistance with the transposition methods in the equivalent surface of hemisphere electrode. Therefore we should calculate the grounding resistance by using the mesh factor. In this paper, we would estimated the grounding value of mesh electrode with water tank model & estimation method using the reduced scale ratio of mesh electrode based on the theory of model electrode & proportional factor according to the reduced scale ratio. And also we have confirmed the accuracy of the empirical formula of model electrode by using by regression analysis.

  • PDF

Presumption for Reduced Scale Model of Mesh Electrod (메쉬접지전극의 축척모형에 관한 추정)

  • Koh, Hee-Seog;Kim, Ju-Chan;Lee, Chung-Sik;Choi, Jong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.29-33
    • /
    • 2002
  • There are a lot of errors and little accuracy when calculating the grounding resistance with the transposition methods in the equivalent surface of hemisphere electrode. Therefore we should calculate the grounding resistance by using the mesh factor, In this paper, we would estimate the grounding value of mesh electrode with water tank model & estimation method using the reduced scale ratio of mesh electrode based on the theory of model electrode & proportional factor according to the reduced scale ratio. And also we have confirmed the accuracy of the empirical formula of model electrode by using the regression analysis.

  • PDF