• 제목/요약/키워드: Membrane fouling

검색결과 651건 처리시간 0.024초

막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석 (Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction)

  • 김경래;김완규;장인성
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF

해수담수화 막 증류 공정에서 유입수 전처리 적용에 따른 막 오염 평가 (Prevention of membrane fouling by roughing filter for the stand-alone MD process)

  • 윤택근;정성필;김혜원;홍승관;이석헌
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.301-307
    • /
    • 2018
  • Membrane distillation (MD) is a thermally driven desalination process with a hydrophobic membrane. MD process has been known to have a lower fouling potential compared to other pressure-based membrane desalination process (NF, RO). However, membrane fouling also occurs in MD process. In this study, the membrane fouling was observed in MD process according to the pre-treatment processes. The filtration and precipitation processes were applied as the pre-treatment to prevent the membrane fouling. The pore sizes of roughing filters were 0.4, 5, 10, 30, and $60{\mu}m$. The concentration of the coagulant was 1.2 mg/L as $FeCl_3$. The membrane fouling on MD membrane was successfully removed with both pre-treatment processes.

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

Membrane fouling in thermophilic membrane bioreactor with different sludge retention times

  • Ince, Elif;Ince, Mahir;Topaloglu, Alikemal
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.343-351
    • /
    • 2018
  • As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.

Preparation and Application of Functional Carbon Whisker Membrane for Separation Process

  • Bae, Sang-Dae;Son, Hee-Jong;Jung, Chul-Woo
    • 한국환경과학회지
    • /
    • 제17권11호
    • /
    • pp.1235-1241
    • /
    • 2008
  • Membrane separation is extensively used for water/wastewater treatment because of its efficiency separation processes. However, particles in the feed water can deposit and accumulate on the membrane surface to created cake layer. As a consequence, the selectivity of the membrane and flux through the membrane are decreased, which is called fouling/blocking phenomenon. In order to solve fouling problem, we developed a novel membrane named Carbon Whisker Membrane (CWM) which contains vapor-grown carbon fibers/whiskers on the surface of the membrane and a layer of carbon film coated on the ceramic substrate. We firstly employed polymethyl methacrylate (PMMA) as a testing material to investigate the fouling mechanism. The results suggested that Carbon Whiskers on the surface of the membrane can prevent the directly contact between the membrane body and particles so that the fouling/blocking could not occurred easily compared to the membrane without carbon whiskers. We also researched the relationship with the diameter, density of carbon whisker on the membrane surface and total flux of solutions. Finally, we will be able to control the diameter and density of carbon whiskers on the membrane and existence of carbon whiskers on the membrane, it is important factor, might be prevent fouling/blocking in the water treatment.

막여과 정수처리 공정에서 온도보정차압 식의 파울링 지표로서의 활용성 검토 (Applicability of Temperature Correction Trans-membrane Pressure as a Fouling Index of Membrane Water Treatment Process)

  • 김민재;임재림;이경혁;이영주;김수한
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.1-8
    • /
    • 2016
  • Temperature correction trans-membrane pressure (TC-TMP) is frequently used as a fouling index in membrane water treatment plants. TC-TMP equation is derived based on an assumption that the total membrane resistance (i.e. the sum of the intrinsic membrane resistance and fouling resistance) is not affected by temperature. This work verified the validity of this assumption using microfiltration (MF) and ultrafiltration (UF) membranes with and without fouling. The foulants used in the work were kaolin (inorganic) and humic acid (organic). The intrinsic resistances of MF and UF membranes remains at constant values regardless of temperature change. When the same amount of foulants were accumulated on the membrane, inorganic fouling resistance with kaolin was constant regardless of temperature change while organic fouling resistance with humic acid decreased at higher temperatures, which means that TC-TMP cannot be used as a fouling index when organic fouling occurs in a real field application. Since TC-TMP underestimates the amount of fouling at higher temperatures, more attention should be necessary in the operation of membrane water treatment plant in a hotter season like summer.

가압식 분리막 여과에서 무기입자의 존재가 유기파울링에 미치는 영향 (Effect of Inorganic Particles on Organic Fouling in Pressurized Membrane Filtration)

  • 장호석;김정환
    • 멤브레인
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2020
  • 본 연구에서는 가압식 분리막 여과에서 무기입자의 존재가 유기파울링에 미치는 영향을 관찰하였다. 유기파울링의 유발을 위해 알긴산나트륨(sodium alginate, SA)를 이용한 정밀여과 실험에서 무기 실리카(SiO2) 입자의 존재 유무와 상관없이 분리막 파울링은 여과초기 완전공극막힘에서 여과시간이 경과할수록 케이크 형성에 의해 주로 지배되었다. 그러나 무기입자의 존재 시 정압여과에서 알긴산나트륨 파울링 케이크 비저항값과 압축성은 상대적으로 낮게 관찰되었고 이로 인해 낮은 파울링 속도가 관찰되었다. 동일한 시료를 이용한 정량여과 실험을 수행한 결과 정압여과에 비해 정량여과에서 여과초기 공극막힘현상 및 파울링 속도는 더욱 증가하였다. 이와 같은 현상은 파울링층이 지닌 압축성으로 막간차압의 증가 시 케이크 비저항값이 함께 증가하였기 때문인 것으로 판단된다. 알긴산나트륨과 실리카 입자가 함께 존재 시 알긴산나트륨이 단독으로 존재하는 것보다 수리학적 세정을 통한 파울링 제거효과는 더욱 좋은 것으로 관찰되었다.

Impacts of sludge retention time on membrane fouling in thermophilic MBR

  • Ince, Mahir;Topaloglu, Alikemal
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.245-253
    • /
    • 2018
  • The aim of this study is to investigate the membrane fouling in a thermophilic membrane bioreactor (TMBR) operated different sludge retention times (SRTs). For this purpose, TMBR was operated at four different SRTs (10, 30, 60 and 100 days). Specific cake resistance (${\alpha}$), cake resistance, gel resistance, total resistance, MFI (modified fouling index) and FDR (flux decrease ratio) were calculated for all SRTs. It was observed that flux in the membrane increases with rising SRT although the sludge concentrations in the TMBR increased. The steady state flux was found to be 31.78; 34.70; 39.60 and 43.70 LMH ($Liter/m^2/h$) for the SRTs of 10, 30, 60 and 100 days respectively. The concentrations of extracellular polymeric substance (EPS) and soluble microbial product (SMP) decreased with increasing SRT. The membrane fouling rate was higher at shorter SRT and the highest fouling rate appeared at an SRT of 10 d. Both the sludge cake layer and gel layer had contribution to the fouling resistance, but the gel layer resistance value was dominant in all SRTs.

막면 세균 증식에 의한 막오염에 관한 연구 (Effect of Membrane Fouling due to Micro-organism Growth on the Membrane Surface)

  • 김형수
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.36-41
    • /
    • 1999
  • High quality drinking water can be produced by membrane separation process. A major problem in the current system is a membrane fouling control. In order to investigate membrane fouling due to E.coll removal, lab scale experiment using MF and UF and semi pilot plant experiment using UV radiation or not was performed. AS a result, the possibility of membrane fouling control by repressing of micro-organism on the membrane surface was clearly verified. But it was not clearly verified in this experiment the combined effect with other factors such as Turbidity, organic and inorganic matters.

  • PDF