• 제목/요약/키워드: Medium Voltage Motor

검색결과 37건 처리시간 0.023초

결합 인덕터를 갖는 플라잉-커패시터 모듈러 멀티레벨 컨버터 (Flying-Capacitor Modular Multilevel Converters with Coupled Inductors)

  • 리덕중;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.288-289
    • /
    • 2018
  • In this paper, the coupled inductor scheme instead of noncoupled inductors is suggested to reduce the dimension, weight and cost of the magnetic core. The simulation results have verified the effectiveness of the flying-capacitor MMC with coupled inductors and its control method for medium-voltage induction motor drives at low-speed operation.

  • PDF

중전압 전동기 구동시스템을 위한 결합 인덕터를 갖는 플라잉 커패시터 MMC (Flying-Capacitor Modular Multilevel Converters with Coupled Inductors for Medium-Voltage Motor Drive System)

  • 리덕중;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.173-174
    • /
    • 2018
  • This paper proposes the coupled inductor instead of four non-coupled inductors in each leg of the flying-capacitor modular multilevel converter (MMC) to reduce the dimension, weight and cost of the magnetic core. The simulation results have verified the effectiveness of the proposed coupled inductor.

  • PDF

대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터 (New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications)

  • 양승욱;최규하;목형수
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.209-215
    • /
    • 2006
  • 본 논문에서는 전압원 인버터의 출력전압 파형을 개선하여 PWM방식을 사용할 수 없는 중 대용량급 모터드라이버 및 UPS, STATCOM, SVC등에 적용하기 위한 새로운 3상 전압원 24-스텝 인버터를 제안한다 보조회로로서 사용한 컨버터로 리플전압을 발생시키고 이를 기존의 12-스텝 인버터에 주입하는데 한대의 링크를 사용하면 12-스텝 동작이 24-스텝으로 전환되며 보조 변압기의 1차 권선을 2N(N=1,2,3...)으로 늘리면 12M-스텝(M=2,3,4..)으로 전환된다. 본 방식의 타당성을 실험 및 시뮬레이션을 통하여 입증하였다.

Characteristics of Disk-type Linear Ultrasonic Motor for Application to x-y Stage

  • Lim Kee-Joe;Park Seong-Bee;Yun Yong-Jin;Lee Kee-Young;Kang Seong-Hwa;Lee Jong-Sub;Jeong Su-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.101-105
    • /
    • 2006
  • In this paper, a disk-type ultrasonic motor using a combination of radial and bending vibration modes is newly designed and fabricated. The characteristics of the test motor are also measured. By means of traveling elastic wave induced at the surface of circumference of the elastic disk, a steel bar in contact with the surface of circumference of the elastic disk bonded onto the piezoelectric ceramic disks is driven in both directions by changing the sine and cosine voltage inputs. The stator of the motor is composed of two sheets of piezoelectric ceramic disks to bond onto both surfaces of an elastic disk, respectively. As a result, the diameter of the elastic body is increased and the resonant frequency is decreased. The resonant frequency of the stator is about 92 kHz, which is composed with piezoelectric ceramic disks of 28 mm in diameter and 2 mm in thickness, and an elastic body of 32 mm in diameter and 2 mm in thickness. A driving voltage of 20 VPP Produces 200 rpm with a torque of 1Nm and an efficiency of about 10%.

A Practical Algorithm for Selective Harmonic Elimination in Five-Level Converters

  • Golshan, Farzad;Abrishamifar, Adib;Arasteh, Mohammad
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1650-1658
    • /
    • 2018
  • Multilevel converters are being widely used in medium-voltage high-power applications including motor drive systems, utility power transmission, and distribution systems. Selective harmonic elimination (SHE) is a well-known modulation method to generate high quality output voltage waveforms. This paper presents a new simple practical method for generating a generalized five-level waveform without selected low order harmonics. This method is based on a phase-shifted expression for the SHE problem, which can analytically calculate the exact values of switching angles and the feasible modulation index range for three-level and five-level waveforms. The proposed method automatically determines the number of transitions between levels and generates proper output waveform without solving complex trigonometric equations. Due to the simplicity of the computational burden, the real-time implementation of the proposed algorithm can be performed by a simple processor. Simulation and experiment results verify the correctness and effectiveness of the proposed method.

Performance Evaluation of Various Bus Clamped Space Vector Pulse Width Modulation Techniques

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1244-1255
    • /
    • 2017
  • The space vector pulse width modulation (SVPWM) technique is a popular PWM method for medium voltage drive applications. Conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are the most common SVPWM techniques. This paper evaluates the performance of various advanced BCSVPWM strategies in terms of their harmonic distortion and switching loss based on a uniform frame work. A uniform frame work, pulse number captures the performance parameter variations of different SVPWM strategies for various number of samples with heterogeneous pulse numbers. This work compares different advanced BCSVPWM techniques based on the modulation index and location of the clamping position (zero vector changing angle ) of a phase in a line cycle. The frame work provides a fixed fundamental frequency of 50Hz. The different BCSVPWM switching strategies are implemented and compared experimentally on a 415V, 2.2kW, 50Hz, 3-phase induction motor drive which is fed from an IGBT based 2 KVA voltage source inverter (VSI) with a DC bus voltage of 400 V. A low cost PIC microcontroller (PIC18F452) is used as the controller platform.

Pulse Counting Sensorless Detection of the Shaft Speed and Position of DC Motor Based Electromechanical Actuators

  • Testa, Antonio;De Caro, Salvatore;Scimone, Tommaso;Letor, Romeo
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.957-966
    • /
    • 2014
  • Some of DC actuators used in home automation, office automation, medical equipment and automotive systems require a position sensor. In low power applications, the introduction of such a transducer remarkably increases the whole system cost, which justifies the development of sensorless position estimation techniques. The well-known AC motor drive sensorless techniques exploiting the fundamental component of the back electromotive force cannot be used on DC motor drives. In addition, the sophisticated approaches based on current or voltage signal injection cannot be used. Therefore, an effective and inexpensive sensorless position estimation technique suitable for DC motors is presented in this paper. This technique exploits the periodic pulses of the armature current caused by commutation. It is based on a simple pulse counting algorithm, suitable for coping with the rather large variability of the pulse frequency and it leads to the realization of a sensorless position control system for low cost, medium performance systems, like those in the field of automotive applications.

Novel Switching Table for Direct Torque Controlled Permanent Magnet Synchronous Motors to Reduce Torque Ripple

  • Arumugam, Sivaprakasam;Thathan, Manigandan
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.939-954
    • /
    • 2013
  • The Direct Torque Control (DTC) technique for Permanent Magnet Synchronous Motors (PMSM) is receiving increased attention due to its simplicity and robust dynamic response when compared with other control techniques. The classical switching table based DTC results in large flux and torque ripples in the motors. Several studies have been reported in the literature on classical DTC. However, there are only limited studies that actually discuss or evaluate the classical DTC. This paper proposes, novel switching table / DTC methods for PMSMs to reduce torque ripples. In this paper, two DTC schemes are proposed. The six sector and twelve sector methodology is considered in DTC scheme I and DTC scheme II, respectively. In both DTC schemes a simple modification is made to the classical DTC structure. The two level inverter available in the classical DTC is eliminated by replacing it with a three level Neutral Point Clamped (NPC) inverter. To further improve the performance of the proposed DTC scheme I, the available 27 voltage vectors are allowed to form different groups of voltage vectors such as Large - Zero (LZ), Medium - Zero (MZ) and Small - Zero (SZ), where as in DTC scheme II, all of the voltage vectors are considered to form a switching table. Based on these groups, a novel switching table is proposed. The proposed DTC schemes are comparatively investigated with the classical DTC and existing literatures through theory analysis and computer simulations. The superiority of the proposed DTC method is also confirmed by experimental results. It can be observed that the proposed techniques can significantly reduces the torque ripples and improves the quality of current waveform when compared with traditional and existing methods.

인터리빙 PFC를 적용한 모터구동 인버터 시스템 설계 (Design of the Inverter Motor Drive System Applied to PFC using Interleaving Method)

  • 윤성식;최현의;김태우;안호균;박승규;윤태성;곽군평
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.14-19
    • /
    • 2010
  • In this paper, using interleaved power factor correction how to improve the inverter efficiency studied. Interleaved method can reduce the conduction losses and the inductor energy. Generally, critical conduction mode (CRM) boost PFC converter used low power level because of the high peak currents. if you use the interleaved mode, CRM PFC can be used medium or high power application. interleaved CRM PFC can reduce current ripple for higher system reliability and size of buck capacitor and EMI filter size. Interleaved CRM PFC that is installed in front of inverter can maintain the constant voltage regardless of the input voltage.

V/f 스칼라 제어 영구자석 동기 전동기의 안정적 초기 구동 기법 (A Stable Startup Method of V/f Scalar Controlled Permanent Magnet Synchronous Motors)

  • 김현성;이상민;이기복
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.395-403
    • /
    • 2020
  • This study presents a stable start-up strategy for v/f scalar-controlled permanent magnet synchronous motors (PMSMs). The v/f-controlled PMSMs easily lose synchronism under low-speed conditions if an insufficient stator voltage is applied to the machine due to errors in measured motor parameters and inverter nonlinearity, such as inverter dead time and on-state voltage drop. The proposed method adopts the I/f control method to ensure a stable start at low speeds and then switches to the v/f control method at medium speeds. A smooth transition method from I/f control to v/f control is proposed to minimize the oscillation of the stator current and rotor speed during transition. Moreover, the stability of the I/f and v/f control methods is analyzed using a small-signal model. Simulation and experimental results are provided to verify the performance of the proposed control strategy.