• Title/Summary/Keyword: Medical simulation

Search Result 1,328, Processing Time 0.024 seconds

Performance analysis of OFDM Wireless Transmission System for Medical Information transmission in Multi-path fading channel Environment (다중경로 페이딩 채널 환경에서 의료정보 전송을 위한 OFDM 무선 전송시스템 성능 분석)

  • Seo, In-Hye;Kang, Heau-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • In this paper, aim to suggest the medical information wireless transmission system to provide the mobility of medical service by means of wireless area network which makes it possible, home or at a long range, to check and oversee the state of patients, and to can out a simulation. The proposed method converts medical information to digital data in an emergency and sends them to mobile terminals such as PDAs to make possible swift first aid. The simulation took advantage of the OFDM transmission method based on IEEE 802.1la in order to send reliable medical information in mobile wireless channel environment, and analyzed the system performance by applying convolution encoding to transmit reliable information in AWGN and 3-ray mobile multipath fading channel environment.

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.

Diagnostic Power of Blood Parameters as Screening Markers in Gastric Cancer Patients

  • Pietrzyk, Lukasz;Plewa, Zbigniew;Denisow-Pietrzyk, Marta;Zebrowski, Remigiusz;Torres, Kamil
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4433-4437
    • /
    • 2016
  • Background: Gastric cancer (GC) is the fifth most common cancer worldwide. Since development is usually asymptomatic, it is generally diagnosed at an advanced stage. The value of screening in patients with nonspecific symptoms for GC is controversial. Aim: The study aimed to evaluate whether hematological parameters (platelet count (PC), mean platelet volume (MPV), MPV/PC ratio, red blood cell distribution width (RDW), neutrophil to lymphocyte ratio (NLR), and platelet to lymphocyte ratio (PLR)) are useful markers to differentiate between gastric cancer patients and healthy individuals. Materials and Methods: Sixty-one patients with gastric cancer and sixty-one healthy individuals were enrolled to the survey and retrospective analysis of selected blood parameters were performed. Results: The mean values of PC, MPV, RDW, NLR, and PLR were significantly higher in GC patients compared to the control group. No statistical differences were observed in MPV/PC ratios. Likewise, no significant statistical differences were revealed in values of blood parameters among TNM stage groups. The RDW showed the highest diagnostic specificity and sensitivity. Conclusions: Hematological parameters: PC, MPV, RDW, NLR, PLR have diagnostic power and can discriminate patients with gastric cancer from patients without cancer. Blood parameters compared with clinical symptoms might alert physicians and patients and lead to performancce of upper gastrointestinal endoscopy, the gold standard in gastric cancer screening and therebly increase the early detection of cancer.

A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment (고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구)

  • Kwak, Keun-Tak;Kim, Yang-Soo;Kwon, Hyoung-Cheol;Kim, Jung-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.

Modeling and Simulation of Scheduling Medical Materials Using Graph Model for Complex Rescue

  • Lv, Ming;Zheng, Jingchen;Tong, Qingying;Chen, Jinhong;Liu, Haoting;Gao, Yun
    • Journal of Information Processing Systems
    • /
    • v.13 no.5
    • /
    • pp.1243-1258
    • /
    • 2017
  • A new medical materials scheduling system and its modeling method for the complex rescue are presented. Different from other similar system, first both the BeiDou Satellite Communication System (BSCS) and the Special Fiber-optic Communication Network (SFCN) are used to collect the rescue requirements and the location information of disaster areas. Then all these messages will be displayed in a special medical software terminal. After that the bipartite graph models are utilized to compute the optimal scheduling of medical materials. Finally, all these results will be transmitted back by the BSCS and the SFCN again to implement a fast guidance of medical rescue. The sole drug scheduling issue, the multiple drugs scheduling issue, and the backup-scheme selection issue are all utilized: the Kuhn-Munkres algorithm is used to realize the optimal matching of sole drug scheduling issue, the spectral clustering-based method is employed to calculate the optimal distribution of multiple drugs scheduling issue, and the similarity metric of neighboring matrix is utilized to realize the estimation of backup-scheme selection issue of medical materials. Many simulation analysis experiments and applications have proved the correctness of proposed technique and system.

Simulation on the Change of Practice Pattern after the Introduction of 7 Diagnosis-related Groups Prospective Payment System in a University Hospital (7개 질병군 포괄수가제 도입에 따른 일개 대학병원의 진료행태 변화 모의실험)

  • Shin, Sam-Chul;Kang, Gil-Won;Kim, Sang-Won
    • Health Policy and Management
    • /
    • v.23 no.2
    • /
    • pp.103-111
    • /
    • 2013
  • Seven diagnosis-related groups (DRGs) prospective payment system is going to expand to all hospitals including university hospitals this year. However there are few studies on the change of practice pattern under prospective payment system in the university hospital setting. So This study was intended to predict the practice pattern change after the introduction of 7 DRGs prospective payment system in a university hospital setting. To predict the change of practice pattern, this study used simulation technique. Five hundred and nineteen patients classified as 5 DRGs in a university hospital were selected for simulation. The change of practice pattern were predicted based on clinicians' opinion. We also predicted payment change by service items. Major findings of this study are as follows. First, the total medical payment was reduced by 14.4%. The drug payment change (8.8%) took most of total payment reduction. The followings are the change of treatment material cost (3.2%), the change of laboratory tests cost (1.8%), the change of room charge (0.5%), and other payment change (0.1%), respectively. Second, most of the reduction in total medical payment resulted from the decreased amount of medical services themselves. The transfer of medical services to outpatient setting took up only 4.9% of the total payment reduction. The change of unit price or composition took up 5.5% of the total payment reduction. In this study we found that it is possible to reduce the inpatient services through practice pattern change in university hospital setting. However, it needs to be careful to adjust DRG payment after the reduction of provided services, because most of reduction was not due to service transfer but to service volume reduction. It is desirable to utilize the saving from practice pattern change as incentive to improve quality of care.

Fate of pulmonary nodules detected by computer-aided diagnosis and physician review on the computed tomography simulation images for hepatocellular carcinoma

  • Park, Hyojung;Kim, Jin-Sung;Park, Hee Chul;Oh, Dongryul
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.116-124
    • /
    • 2014
  • Purpose: To investigate the frequency and clinical significance of detected incidental lung nodules found on computed tomography (CT) simulation images for hepatocellular carcinoma (HCC) using computer-aided diagnosis (CAD) and a physician review. Materials and Methods: Sixty-seven treatment-$na{\ddot{i}}ve$ HCC patients treated with transcatheter arterial chemoembolization and radiotherapy (RT) were included for the study. Portal phase of simulation CT images was used for CAD analysis and a physician review for lung nodule detection. For automated nodule detection, a commercially available CAD system was used. To assess the performance of lung nodule detection for lung metastasis, the sensitivity, negative predictive value (NPV), and positive predictive value (PPV) were calculated. Results: Forty-six patients had incidental nodules detected by CAD with a total of 109 nodules. Only 20 (18.3%) nodules were considered to be significant nodules by a physician review. The number of significant nodules detected by both of CAD or a physician review was 24 in 9 patients. Lung metastases developed in 11 of 46 patients who had any type of nodule. The sensitivities were 58.3% and 100% based on patient number and on the number of nodules, respectively. The NPVs were 91.4% and 100%, respectively. And the PPVs were 77.8% and 91.7%, respectively. Conclusion: Incidental detection of metastatic nodules was not an uncommon event. From our study, CAD could be applied to CT simulation images allowing for an increase in detection of metastatic nodules.

Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

  • Kim, Moo-Sub;Kubo, Kazuki;Monzen, Hajime;Yoon, Do-Kun;Shin, Han-Back;Kim, Sunmi;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.232-235
    • /
    • 2016
  • The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation by Monte-Carlo simulation using the CT image, and will evaluate the accuracy of dose estimation of this TPS. The complicated geometry like a human body allows defining using the lattice function in MCNPX. The results of simulation such as flux or energy deposition averaged over a cell, can be obtained using the features of the tally provided by MCNPX. To assess the dose distribution and therapeutic effect, dose distribution was displayed on the CT image, and dose volume histogram (DVH) was employed in our developed system. The therapeutic effect can be efficiently evaluated by these evaluation tool. Our developed TPS could be effectively performed creating the voxel model from CT image, the estimation of each dose component, and evaluation of the BNCT plan.

Feasibility Study of Improved Patch Group Prior Based Denoising (PGPD) Technique with Medical Ultrasound Imaging System

  • Kim, Seung Hun;Seo, Kanghyen;Kang, Seong Hyeon;Kim, Jong Hun;Choi, Won Ho;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.55-59
    • /
    • 2017
  • The purpose of this study was to quantitatively evaluate image quality using intensity profile, coefficient of variation (COV), and peak signal to noise ratio (PSNR) with respect to noise reduction techniques in the ultrasound images. For that purpose, we compared with the median filter, Rudin-Osher-Fatemi (ROF), Anscombe and proposed patch group prior based denoising (PGPD) techniques. To evaluate image quality, the Shepp-Logan phantom and the ultrasound image were acquired using simulation and experiment, respectively. According to the results, the difference of intensity profile using PGPD technique is lowest compared with original Shepp-Logan phantom. In simulation, the measured COV was 0.249, 0.198, 0.198, 0.177, and 0.080 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Also, in experimental image, the measured COV was 0.245, 0.230, 0.231, 0.242 and 0.187 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Especially, when we used PGPD technique, the PSNR has highest value in both simulation and experiment. In this study, we performed simulation and experiment study to compare various denoising techniques in the ultrasound image. We can expect the PGPD technique to improve in medical diagnosis with excellent noise reduction.

Performance Evaluation of the QoS Guarantee Mechanisms for Medical Multimedia Network Using DiffServ (DiffServ를 이용한 의료용 멀티미디어 네트워크의 QoS 보장에 대한 성능평가)

  • 이상학
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1505-1516
    • /
    • 2001
  • The goal of Medical multimedia server is to develop computer hardware and software which would enable electronic access, storage, transmission, and display of patient data and images. Since the current network only provides so called "best-effort" services, it is impossible to satisfy QoS guarantee that is required for real time application services for emergency room, operating room etc. Accordingly, world-wide research is being made for a variety of services to provide QoS. he goal of DiffServ is to offer scalable differentiated service in Internet which are made possible by traffic classification and conditioning only performed at an edge(or a boundary) node. In case DiffServ was deployed in the Medical multimedia network, it is difficult to estimate how the QoS mechanism would affect totally the network performance. Therefore, we need to verify by simulation the design of algorithm which provide a variety of differentiated services. In QoS for Medical multimedia network, a simulator is designed and implemented using OPNET to investigate the performance of DiffServ QoS support mechanism. The developed DiffServ simulator may generate packets according to random, and bursty traffic models in order to incorporate diverse traffic conditions in the Medical multimedia network environment. Based on our simulation results, we confirmed that service differentiation is possible by using the EF(Expedited Forwarding) class in DiffServ networks.

  • PDF