• Title/Summary/Keyword: Medical radioisotope

Search Result 115, Processing Time 0.021 seconds

Galactosemia Detected by Neonatal Screening Test (신생아 선별검사에 의해 발견된 갈락토스혈증에 대한 고찰)

  • Park, Il Sung;Cho, Hye Jung;Lee, Dong Hwan;Song, Jung Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.440-446
    • /
    • 2003
  • Purpose : The genetic disturbance of galactosemia is expressed as a cellular deficiency of either galactose-1-phosphate uridyltransferase(GALT) or galactokinase(GALK) or UDP galactose 4-epimerase(GALE). To find-out the pattern of galactosemia in Korea, we retrospectively analyzed cases of galactosemia detected by neonatal screening program. Methods : We analyzed medical records of patients who visited Soonchunhyang University Hospital at age of 1 month after showing abnormalities in neonatal screening of galactosemia. For accurate diagnosis, galactose was measured by enzyme immunoassay(EIA) and fluorophotometer, also galactose-1-phosphate by fluorophotometer. Enzyme activities of GALK, GALT and GALE in RBC and galactose-1-phosphate were measured by radioisotope assay(RIA). Beutler test were done. Patients went on a lactose-free diet and follow-up tests for galactose, galactose-1-phosphate level and enzyme activity were performed. Results : 10 patients(male : 6, female : 4) were diagnosed as galactosemia. Two patients had GALK deficiency and two had GALT deficiency. Six were GALE deficient showing the largest number. In two patients with GALK deficiency, GALT and GALE activities were normal but GALK activities showed respectively reduced activity. For GALT deficiency, two patients had low GALT activity in RBC and showed genotype of Duarte 2/G(galactosemia) in DNA analysis. In one patient, GALT activity was normal. Three patients seemed to be heterozygote state of GALE deficiency according to GALE activity levels. Four patients showed GALK hyperactivity. Conclusion : GALE deficiency provided the highest number. After lactose-free diet, galactose and galactose-1-phosphate were normaly maintained. Neonatal screening on galactosemia is essential for preventing life-threatening symptoms and an accurate diagnosis is needed for finding out the type of galactosemia which is important for prognosis.

Change of Regional Myocardial Blood Flow After Transmyocardial Laser Revascularization in Porcine Model of Chronic Myocardial Ischemia (돼지 만성 심근허혈 모델에서 경심근레이저혈류재건술 후 국소 심근 혈류량의 변화)

  • Park, Kay-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.662-671
    • /
    • 2001
  • Background: This study was aimed to assess improvement in myocardial perfusion after TMR by measuring regional myocardial blood flow(RMBF) in porcine model of chronic myocardial ischemia. Material and Method: Ameroid ring was placed around the proximal left circumflex coronary artery in fourteen pigs. After 4 weeks, the control group(7 pigs) underwent rethoracotomy only, and the TMR group(7 pigs) underwent Ho:YAG laser TMR at the circumflex territory. After another 4 weeks, the animals were sacrificed for the measurement of RMBF using colored microspheres. The ratio of RMBF between the circumflex territory and the interventricular septum was calculated and compared. Result: At 4 weeks after ameroid constriction, RMBF of the circumflex territory decreased to 46∼89% of RMBF of the interventricular septum. In five of six animals in the TMR group, RMBF of the circumflex territory at 8 weeks after ameroid constriction was higher compared with RMBF at 4 weeks after ameroid constriction. However, the improvement was statistically significant only in two animals. In three of the four animals in the control group, RMBF of the circumflex territory also increased at 8 weeks compared with RMBF at 4 weeks. The degree of increase in RMBF was not different between the control and the TMR groups. Conclusion: In porcine model of chronic myocardial ischemia, the degree of increase in RMBF of the ischemic area after Ho:YAG TMR was not different from the increase by development of native collateral circulation. Perfusion of ischemic myocardium after TMR is not thought to improve to the degree that can be demonstrated by currently available method of assessment such as radioisotope myocardial scintigraphy.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.