• 제목/요약/키워드: Medical measurement

검색결과 2,743건 처리시간 0.03초

보음전의 항산화, 항염증 효능에 관한 실험연구 (The Experimental Study on Antioxidant, Anti-inflammatory Effects of the Boeum-jeon (BEJ))

  • 김수경;조성희;양승정
    • 대한한방부인과학회지
    • /
    • 제36권3호
    • /
    • pp.1-24
    • /
    • 2023
  • Objectives: Boeum-jeon (BEJ) is a herbal formula composed 8 Korean medicinal herbs and is traditionally used to treat inflammatory diseases. In this study, the authors tried to confirm the antioxidant efficacy of BEJ and its anti-inflammatory effect in lipopolysaccharide (LPS)-stimulated RAW 264.7 cells. Methods: In this experiment, results of BEJ on the following two were measured as follows: (1) Antioxidant effects was measured by DPPH Radical scavenging Activity, ABTS Radical scavenging Activity. (2) Anti-Inflammatory effects were evaluated by the production amount of ROS, NO, Cytokine (PGE2, IL-1β, IL-6, TNF-α), COX-2, iNOS, TNF-α, IL-1β, IL-6, HO-1, NQO1 (the previous seven are "mRNA Expression"), COX-2, iNOS, TNF-α, IL-1β, IL-6, HO-1, NQO1, NRF2 (the previous eight are "Protein Expression") ERK, JNK, p38 (the previous three are "Protein Phosphorylation") in LPS-stimulated RAW 264.7 cells. Results: The experimental measurement results are as follows: (1) DPPH Radical scavenging Activity, ABTS Radical scavenging Activity increased in a concentration -dependent manner in the BEJ-treated group. (2) As a result of measuring anti-inflammatory efficacy, the production of ROS, NO, and Cytokine (PGE2, TNF-α, IL-1β, IL-6) in the BEJ-administered group was significantly reduced compared to the control group. (3) Among mRNA Expression levels, COX-2, iNOS, IL-1β, IL-6 and TNF-α was significantly decreased in a concentration-dependent manner than in the control group, and HO-1 and NQO1 were significantly increased in a concentration -dependent manner than in the control group. (4) Among the Protein Expression levels, COX-2, iNOS, IL-1β, IL-6 and TNF-α was significantly decreased in a concentration -dependent manner compared to the control group, and HO-1, NQO1 and NRF2 was significantly increased in a concentration-dependent manner compared to the control group. (5) As a result of Protein Phosphorylation, ERK, p38 and JNK was significantly decreased compared to the control group in a concentration-dependent manner. Conclusions: Boeum-jeon has been experimentally confirmed to have antioxidant and anti-inflammatory effects, and if the evidence for efficacy is reinforced through further studies such as in vivo studies and clinical trials in the future, it can be effectively used to treat various inflammatory diseases such as bladder inflammation and chronic pelvic inflammation.

Hamster 정소상체 정자의 운동성 유도와 증가에 영향을 미치는 Methylxanthine Derivatives 의 효과 (Effects of MethyIxanthine Derivatives on Induction and Enhancement of Hamster Epididymal Sperm Motility)

  • 박용석;송상진;이호준;이상진;김남형;이훈택;정길생
    • 한국가축번식학회지
    • /
    • 제23권1호
    • /
    • pp.29-36
    • /
    • 1999
  • 본 연구는 Hamster 정소상체 정자의 운동성에 영향을 미치는 methylxanthine derivatives 의 효과를 알아보고자 수행하였다 . Pentoxifylline 을 첨가하였을 때 운동 형태에 대한 첨가효과는 정소상체 체부에서 차이를 보였으며, 농도에 대한 변화는 1 mM 농도군에서 현저한 차이를 나타냈다. 2-Deoxya-denosine 첨가군에서도 pentoxifylline 첨가군과 같이 특히 VCL 이 정소상체 체부 정자부터 증가하였으며 다른 농도군에 비해 1 mM 과 2 mM 에서 차이가 났다. Hypoxanthine 첨가군은 1 mM 농도에서 다른 첨가군에 비해 운동 형태가 증가하였다. 그러나 pentoxifylline 과 adenosine 첨가군과는 달리 농도를 달리하여도 뚜렷한 운동형태의 변화는 관찰되지 않았다. VCL 과 VAP 는 pentoxifylline 1 mM 과 2-Deoxyadenosine 1 mM 첨가군에서 정소상체 체부 정자의 운동성이 증가하고 hypoxanthine 1 mM 첨가군도 유의하게 증가하였다. 결론적으로 hamster 정소상체 정자의 운동성은 적정한 농도의 methylxanthine derivatives 의 첨가로 증가됨을 알 수 있었다.

  • PDF

공공보건시설 환경색채이미지 어휘 특성 (Characteristics of Environmental Color Image Vocabulary for Public Healthcare Facility)

  • 박혜경;오지영
    • 한국과학예술포럼
    • /
    • 제31권
    • /
    • pp.171-180
    • /
    • 2017
  • 본 연구는 최근 건강, 웰빙에 대한 관심이 증가함에 따라, 공공의 다수가 이용하는 공공보건시설이 국민건강 증진에 기여하는 색채환경 구축을 위한 색채이미지 특성을 분석하여 공공보건색채 계획 및 지표개발의 데이터로 활용하고자 하는 것을 목적으로 한다. 이를 위하여 기존 관련 선행연구 결과를 종합하였고, 공공보건시설을 유형별로 의료시설(종합병원), 보건시설(보건소), 준치유시설(요양시설)로 구분하였다. 총 18곳의 공공보건시설을 직접 방문하여 측색기로 환경색채를 측색하여 환경색채이미지를 분석하였고, 이에 대한 결과 및 선행연구 결과와 비교분석하여 색채이미지 특성 및 향후 보완할 점들을 도출하였다. 결과는 다음과 같다. 첫 번째, 공공보건시설의 환경색채이미지 어휘와 관련된 선행연구에서는 편안하고 밝은 긍정적인 이미지를 선호하는 것으로 나타났다. 두 번째, 공공보건시설의 환경색채를 직접 측색한 결과, 대부분 Y계열의 고명도, 저채도 색상을 사용하고 있는 것으로 나타났다. 세 번째, 공공보건시설의 환경색채이미지 어휘를 분석한 결과, '내츄럴한' 이미지가 가장 높은 빈도를 나타내었고, 그 외 '은은한', '점잖은' 등의 이미지가 나타나고 있는데, 공공보건시설의 색채이미지어휘간의 특성을 파악하기가 어려웠다. 본 연구는 색채과학과 환경디자인 분야의 융합연구로서, 디자인과 관련된 다학제적 연구 범위를 넓혔으며, 사용자 감성 중심의 환경계획에 도움이 될 것으로 사료된다.

Radioactive Concentrations in Chemical Fertilizers

  • Gwang-Ho Kim;Jae-Hwan Cho
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.195-203
    • /
    • 2022
  • Background: The aim of the present study was to determine radioactive concentrations in fertilizers known to contain essential nutrients. Results of this study could be used as basic data to monitor the impact of chemical fertilizers on the environment and public health. Nitrogen fertilizers, calcium fertilizers, sulfur fertilizers, phosphate acid fertilizers, and potassium chloride fertilizers were used in this study. Materials and Methods: Five chemical fertilizers were pulverized, placed in polyethylene containers, and weighed. The time to measure each specimen was set to be 3,600 seconds for a scintillator-based gamma-ray spectroscopy system. Concentration of gamma radionuclide was analyzed based on obtained spectra. At the end of the measurement, the spectrum file was stored and used to calculate radioactive concentrations using a gamma-ray spectrometer software. Results and Discussion: In the nitrogen fertilizer, 3.49 ± 5.71 Bq/kg of 137Cs, 34.43 ± 7.61 Bq/kg of 134Cs, and 569.16 ± 91.15 of 40K were detected whereas 131I was not detected. In the calcium fertilizer, 5.74 ± 4.40 Bq/kg of 137Cs (the highest concentration among all fertilizers), 22.37 ± 5.39 Bq/kg of 134Cs, and 433.67 ± 64.24 Bq/kg of 40K were detected whereas 131I was not detected. In the sulfur fertilizer, 347.31 ± 55.73 Bq/kg of 40K, 19.42 ± 4.53 Bq/kg of 134Cs, 2.21 ± 3.49 of 137Cs, and 0.04 ± 0.22 Bq/Kg of 131I were detected. In the phosphoric acid fertilizer, 70,007.34 ± 844.18 Bq/kg of 40K (the highest concentration among all fertilizers) and 46.07 ± 70.40 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. In the potassium chloride fertilizer, 12,827.92 ± 1542.19 Bq/kg of 40K was and 94.76 ± 128.79 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. The present study examined inorganic fertilizers produced by a single manufacturer. There might be different results according to the country and area from which fertilizers are imported. Further studies about inorganic fertilizers in more detail are needed to create measures to reduce 40K. Conclusion: Measures are needed to reduce radiation exposure to 40K contained in fertilizers including phosphoric acid and potassium chloride fertilizers.

O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서 (Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process)

  • 남현진;강철;이승우;김선우;박세훈
    • 마이크로전자및패키징학회지
    • /
    • 제29권4호
    • /
    • pp.21-27
    • /
    • 2022
  • 저렴한 전도성 흑연을 인쇄전자 공법으로 유연 압력 센서를 개발하였다. 유연 압력 센서는 의료, 게임, AI 등 미래 산업에 활용될 소재로 각광받고 있다. 유연 압력 센서용 인쇄전극을 다양한 전기-기계적 특성을 평가한 결과 최대인장률 20%, 30°의 인장/굽힘, 간이 맥박 시험에서 일정한 저항 변화율을 보였다. 이렇게 검증이 완료된 전극을 시뮬레이션하여 더 적합한 matrix 패턴을 설계하였다. Serpentine 패턴을 활용하여 matrix 패턴 제작과 인캡슐레이션을 동시에 진행할 수 있는 공정을 활용하였다. 인쇄된 흑연 전극의 한쪽 면에 접착력 증가를 위한 O2 플라즈마 표면처리하고, 90°회전시켜, 라미네이션 공정을 통해 2개의 전극을 하나로 제작하였다. 이렇게 제작된 matrix 패턴을 인체의 손목 맥박 위치에 부착하여 실측을 진행한 결과 남녀 상관없이 일정한 저항 변화율을 보였다.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰 (A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging)

  • 김지현;이주영;박훈희
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

자연어처리 기법을 적용한 무기체계의 상호운용성 평가방법 (Evaluation method for interoperability of weapon systems applying natural language processing techniques)

  • 김용균;이동현
    • 한국국방기술학회 논문지
    • /
    • 제5권3호
    • /
    • pp.8-17
    • /
    • 2023
  • 현재의 무기체계는 다양한 표준과 프로토콜이 적용된 복합무기체계가 운용되어서 전장에서 연합 및 합동작전시 원활한 정보교환 실패의 위험이 있다. 무기체계간 신속한 상황판단으로 핵심표적에 대한 정밀타격을 수행하기 위한 무기체계들의 상호운용성은 전쟁수행의 핵심요소이다. 한국군은 전력화 이후 다수의 소프트웨어 및 하드웨어의 형상변경과 성능개선 소요가 발생하고 있으나, 상호운용성에 미치는 영향에 대한 검증제도가 없으며, 관련 시험 도구 및 시설도 전무한 실정이다. 또한 연합 및 합동훈련시 무기 / 전력지원체계의 세부 운용방식과 소프트웨어를 임의로 변경한 후 이에 따른 사용자 간 오류가 빈번히 발생하고 있다. 그래서 주기적인 무기체계간 상호운용성 검증이 필요하다. 이러한 문제를 해결하기 위하여 사람이 평가기간을 잡아서 1번 평가를 진행하는것이 아니라, AI가 24시간 무기 / 전력지원 체계간 상호운용성을 지속적으로 평가하여 전쟁수행능력을 고도화해야 한다, 이러한 문제점을 해결하기 위하여 자연어 처리기법(①Word2Vec 모델 ②FastText 모델 ③Swivel 모델)을 적용(공개된 알고리즘과 소스코드 사용)하여 국방상호운용성 능력향상을 위한 사전연구를 수행하였다. 이 실험의 결과를 바탕으로 사람에 의존하지 않고, 자동화된 국방상호운용성 평가도구를 구현하기 위한 방법론(자연어 처리 모델을 통한 상호운용성 소요평가 / 수준측정의 자동화된 평가)을 향후 제시하고자 한다.

  • PDF

DNA 길이와 혼합 종 개수 예측을 위한 합성곱 신경망 (Convolution Neural Network for Prediction of DNA Length and Number of Species)

  • 승희;김예원;이효민
    • Korean Chemical Engineering Research
    • /
    • 제62권3호
    • /
    • pp.274-280
    • /
    • 2024
  • 기계학습법의 신경망 기술을 이용한 자료분석은 질병 유전자 탐색 및 진단, 신약 개발, 약인성 간 손상 예측 등과 같은 다양한 분야에서 활용되고 있다. 질병 특징 발견을 위한 자료분석은 DNA 정보를 기반으로 이루어질 수 있다. 본 연구에서는 DNA의 분자 정보 중 DNA의 길이와 용액 내 DNA의 길이별 종 개수를 예측하는 신경망을 개발하였다. 겔 전기영동을 통한 기존 방법론의 시간 소요 한계점을 해결하고자, 미세유체역학적 농축 장치의 동역학 자료를 분석 대상으로 하여 실험 분석 과정 중의 시간 소요 문제점을 해결하였다. 동역학 자료를 공간시간 지도로 재구성하여 학습 및 예측에 필요한 계산용량을 낮추었으며, 공간시간 지도에 대한 분석 정확도를 높이기 위해 합성곱 신경망을 활용하였다. 그 결과, 단일 변수 회귀로써의 단일 DNA 길이 예측과 복합 변수 회귀로써의 다종 DNA 길이의 동시 예측 및 이진 분류로써의 DNA 혼합 종 개수 예측을 성공적으로 수행하였다. 추가적으로, 예측 과정 중 발생할 수 있는 예측 편향을 학습 자료 구성 방식을 통한 해결책을 제시하였다. 본 연구를 활용한다면, 광학 측정 자료를 이용하는 액체생검 기반의 세포유리 DNA 분석 및 암 진단 등의 의학 자료 분석을 효과적으로 수행할 수 있을 것이다.

Clinical outcomes of open Latarjet-Patte procedures performed for recurrent anterior shoulder instability with primary bone loss versus failed arthroscopic Bankart repair

  • Neil Gambhir;Aidan G. Papalia;Matthew G. Alben;Paul Romeo;Gabriel Larose;Soterios Gyftopoulos;Andrew S. Rokito;Mandeep S. Virk
    • Clinics in Shoulder and Elbow
    • /
    • 제27권2호
    • /
    • pp.176-182
    • /
    • 2024
  • Background: This study compares the outcomes of Latarjet-Patte procedures (LPs) performed for primary glenohumeral instability in the setting of critical bone loss (LP-BL) versus salvage surgery performed after a failed arthroscopic Bankart repair (LP-FB). Methods: LP's performed by senior author from 2017 to 2021 were separated into cohorts by LP indication. Data abstracted from electronic medical records included demographic information, preoperative clinical scores, radiological imaging, and complications. Postoperative clinical outcome scores collected after a 2-year minimum follow-up included: patient-reported outcomes measurement information system (PROMIS) upper extremity (UE), PROMIS pain interference, PROMIS pain intensity, American Shoulder and Elbow Surgeons (ASES), and visual analog scale pain scores. Results: A total of 47 patients (LP-BL: n=29, LP-FB: n=18) with a mean age of 29 years (range, 15-58 years) were included in this study. Both cohorts achieved good upper extremity functionality without significant differences as indicated by mean PROMIS UE (LP-BL: 52.6±10.0 vs. LP-FB: 54.6±7.6, P=0.442) and ASES score (LP-BL: 89.9±15.7 vs. LP-FB: 91.5±14.4, P=0.712). However, the LP-FB cohort reported lower levels of pain (LP-FB: 0.5±1.1 vs. LP-BL: 1.9±2.7, P=0.020) at their latest follow-up. There were no significant differences in complication rates including re-dislocation between cohorts (LP-BL: 2/29 [6.9%] vs. LP-FB: 2/18 [11.1%], P=0.629). Conclusions: When performed after failed Bankart repair, the LP results in similar postoperative functional outcomes and similar rates of complications and re-dislocations when compared to the primary indication of recurrent glenohumeral instability in the setting of critical bone loss.