• Title/Summary/Keyword: Medical measurement

Search Result 2,743, Processing Time 0.028 seconds

A Study on Measurement of Capacitive Electrode Motion Artifact (용량성 전극의 동잡음 측정 장치 연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.137-141
    • /
    • 2017
  • The indirect-contact bio-electric measurements using capacitive electrodes show large motion artifacts in comparison with conventional direct-contact measurements. It is necessary to measure the motion artifacts quantitatively, for the researches of reducing the motion artifacts. In this study, a device for quantitative measurement of motion artifacts was built. Using the device, an electrode was rubbed against some cloth(cotton) and the voltage variation of the electrode was measured as motion artifact in several environmental conditions(temperature and relative humidity). The measured waveforms agreed with that expected by the triboelectricity and the prior observations of the motion artifacts. Therefore, the results demonstrated the usability of the measurement system built in this study. The measurement system will be a great contribution to future research for reducing motion artifact.

The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement (간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

Morphological Detection of Carotid Intima-Media Region for Fully Automated Thickness Measurement by Ultrasonogram

  • Park, Hyun Jun;Kim, Kwang Baek
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.250-255
    • /
    • 2017
  • In this paper, we propose a method of detecting the region for measuring intima-media thickness (IMT). The existing methods for IMT measurement are automatic, but the region used for measuring IMT is not detected automatically but often set by the user. Therefore, research on detecting the intima-media region is needed for fully automated IMT measurement. The proposed method uses a morphological feature of the carotid artery visible as two long high-brightness horizontal lines at the upper and lower parts. It uses Gaussian blurring, ends-in search stretching, color quantization using a color-importance-based self-organizing map, and morphological operations to emphasize and to detect the morphological feature. The experimental results for evaluating the performance of the proposed method showed a 97.25% (106/109) success rate. Therefore, the proposed method can be used to develop a fully automated IMT measurement system.

A Study on the Thickness Measurement of Thin Film by Ultrasonic Wave (초음파(超音波)를 이용(利用)한 박막(薄膜)두께 측정(測定)에 관(關)한 연구(硏究))

  • Han, Eung-Kyo;Lee, Jae-Joon;Kim, Jae-Yeol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.27-34
    • /
    • 1988
  • Recently, it is gradually raised necessity that thickness of thin film is measured accurately and managed in industrial circles and medical world. In this study, regarding to the thickness of film which is in opaque object and is beyond distance resolution capacity, thickness measurement was done by MEM-cepstrum analysis of received ultrasonic wave. In measurement results, film thickness which is beyond distance resolution capacity was measured accurately. And within thickness range that don't exist interference, thickness measurement by MEM-ceptrum analysis was impossible.

  • PDF

A Study on 3-D Shape Measurement and Application by using Digital Projection $Moir\acute{e}$ ( I ) (디지털 영사식 무아레를 이용한 3차원 형상 측정과 응용에 관한 연구( I ))

  • Ryu Weon-Jae;Rho Hyung-Min;Lee Dong-Hwan;Kang Young-June
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.88-93
    • /
    • 2005
  • $Moir\acute{e}$ topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by $Moir\acute{e}$ topography has been required, since the method was frequently applied to the engineering and medical fields. The 3-D measurement using projection $Moir\acute{e}$ topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection $Moir\acute{e}$ topography was tested to measuring object with $2\pi-ambiguity$ problems. The experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi-ambiguity$ problems can be effectively overcome so as to treat large step discontinuities in measured objects.

The Design and Implementation of Mouse Activity Measurement System using Infrared Sensor

  • Kwak, Ho-Young;Huh, Jisoon;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.81-89
    • /
    • 2016
  • In this paper, we design and implement a mouse movement measurement system using an infrared sensor called MAMS (Mouse Activity Measurement System). Unlike existing systems, MAMS can measure movements between IREDs. MAMS is removable allowing convenient portability and is also low cost. MAMS automatically measures mouse activity during a pre-set time interval. Since the measured data can be easily stored in a computer system, it is much simpler and more efficient than the Ugo 47420 model. Moreover, MAMS can be used in medical and veterinary field to eliminate manual observations.

Development of Portable Bio-signal Measurement System using Bluetooth for 24-hours Continuous Health Monitoring (24시간 건강상태 모니터링을 위한 Bluethooth를 사용한 소형 저전력 휴대형 Bio-signal 측정 장치를 개발)

  • 정현권;송길섭;나승유;이희영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.81-84
    • /
    • 2001
  • This paper presents a potable bio-signal measurement system using Bluetooth for the 24-hours continuous health state monitoring of the elderly and the disabled. The measurement system has the functions of acquisition of various bio-signals, wireless data transmission and adjustment of parameters such as gain and cut-off frequency. This measurement system is designed according to the international specifications of the recommendation of AAMI (Association for the Advancement of Medical Instrumentation). The design targets of the developing system about volume and power consumption are 20x30x5mm$^3$ and 8mW.

  • PDF

A Lifelog Common Data Reference Model for the Healthcare Ecosystem (디지털 헬스케어 생태계 활성화를 위한 라이프로그 공통데이터 참조모델)

  • Lee, Young-joo;Ko, Yoon-seok
    • Knowledge Management Research
    • /
    • v.19 no.4
    • /
    • pp.149-170
    • /
    • 2018
  • Healthcare lifelog, a personal record relating to disease treatment and healthcare, plays an important role in healthcare paradigm shifts in which medical and information technology converge. Healthcare services based on various healthcare lifelogs are being launched domestically by both large corporations and small and medium enterprises, however, they are being built on an individual platform that is dependent on each company. Therefore, the terms of lifelog data are different as well as the measurement specifications are not uniform. This study proposes a reference model for minimum common data required for sharing and utilization of healthcare lifelog. Literature study and expert survey derived 3 domain, 17 essential items, and 51 sub-items. The model provides definition, measurement data format, measurement method, and precautions for each detailed measurement item, and provides necessary guidelines for data and service design and construction for healthcare service. This study has its significance as a basic research supporting the activation of ecosystem by ensuring interoperability of data between heterogeneous healthcare devices linked to digital healthcare platform.

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

Simple measurement the chelator number of antibody conjugates by MALDI-TOF MS

  • Shin, Eunbi;Lee, Ji Woong;Lee, Kyo Chul;Shim, Jae Hoon;Cha, Sangwon;Kim, Jung Young
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.54-58
    • /
    • 2017
  • Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS) is one of the powerful methods that enable analysis of small molecules as well as large molecules up to about 500,000 Da without severe fragmentation. MALDI-TOF MS, thus, has been a very useful an analytical tool for the confirmation of synthetic molecules, probing PTMs, and identifying structures of a given protein. In recent nuclear medicine, MALDI-TOF MS liner ion mode helps researcher calculate the average number of chelator(or linkage) per an antibody conjugate, such as DOTA-(or DFO-) trastuzumab for labeling a medical radioisotope. This simple technique can be utilized to improve the labeling method and control the quality at the development of antibody-based radiopharmaceuticals, which is very effected to diagnosis and therapy for in vivo tumor cells, with radioisotopes like $^{89}Zr$, $^{64}Cu$, and 177Lu. To minimize the error, MALDI-TOF MS measurement is repeatedly performed for each sample in this study, and external calibration is carried out after data collection.