• Title/Summary/Keyword: Medical device use by U-healthcare

Search Result 8, Processing Time 0.024 seconds

A Study on the Standard of Test Method for Estimation of Usage Environment Safety and Performance of U-health Medical Device (유헬스케어의료기기의 사용환경 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Cha, J.H.;Hur, C.H.;Park, K.J.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • According to graying of population and income enlargement of people, interest about U-Healthcare of new form fusing with IT technology are enlarged. Need a estimation technology and standard of test method for safety and performance considering usage environment of U-Healthcare medical device. In this research, developed the standard of test method for usage environment safety and performance of U-Healthcare medical device referring IEC standards and KS standards.

U-Healthcare Patch Type Wireless Body Temperature Monitoring System (유헬스케어 패치형 무선 체온 모니터링 시스템 구현)

  • Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.

U-Healthcare user's privacy protection protocol with Implantable medical Device of State Information (상태정보에 따른 체내삽입형 장치를 부착한 유-헬스케어 환자의 프라이버시 보호 프로토콜)

  • Jeong, Yoon-Su;Lee, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.297-306
    • /
    • 2012
  • IT technology of U-healthcare system is being grafted onto medical services and the use of U-healthcare system are extending steadily. However, in case of patients using Implantable Medical Device (IMD) in U-healthcare system, patients' privacy protection and safe access to system recently has emerged as a major issue. This paper proposes a patients' privacy protection protocol to prevent any illegal accesses from third parties as state value and action value are synchronized after patients' information virtualization. The proposed protocol can limit the access range of patients' information according to authentication information of hospitals, doctors, nurses, and pharmacies registered in the U-healthcare server. Additionally, this protocol can increase management efficiency for patients' privacy by synchronizing state values and action values only for approved information and, by instituting this process, third parties cannot easily access patients' information.

Patient Monitoring System Base on U-Healthcare (U-Healthcare 기반의 환자 모니터링 시스템)

  • Jung, Won-Soo;Oh, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7B
    • /
    • pp.575-582
    • /
    • 2008
  • The existing patient monitoring system when the patient want own information. The patient confirm information through the medical institution. But the patient monitoring system based on the U-Healthcare, the patient always confirms own information through the mobile device including rfid reader. The patient need RFID middleware design to provide wanting service when the RFID reader read patient's tag information. The RFID middleware is consisted of RFID module, ARM processor and RS-232 interface. The RFID module is used to be inputted user information and RS-232 interface pass information by RFID middleware. Also, This system is embodied by specific patient monitoring system using embedded exclusive use ARM processor. In this paper introduces concept and action principle of RFID middleware and embodied patient monitoring system that use Qt.

Comparative Study on the Definitions of "Home Medical Device" in Korea and in the Global Market (세계 시장과 한국에서의 "가정용 의료기기" 정의에 대한 비교연구)

  • Kim, Y.S.;Kang, H.K.;Park, S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.223-230
    • /
    • 2015
  • There is an increasing trend of medical devices and products moving out of hospitals and clinics into community and residual homes for use by the general public due to both the technological developments and demographic changes resulted from the increased life expectancy and decreased birth rate. In Korea, however, the definition of "home medical device" is rather ambiguous and we thus compared the definition of the term used in the global market with that in Korea. FDA definition of "home medical device" includes the devices intended for use in both professional healthcare facilities and home. The KFDA, does not provide the definition for the "home medical device"and the definition has only been inferred from the results of consumer surveys. With a paradigm shift in advent of u-healthcare era, the definition of "home medical device" in Korea should include the medical devices that could be used both at hospitals and at home.

  • PDF

Design of Patient Authentication Model in u-healthcare Environment using Coalition ID (연합 ID를 이용한 u-헬스케어 환경의 환자 인증 모델 설계)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • To provide medical services to patients who have a terminal illness, recent hospital patients to monitor the state of the device attached to the body, the body insertion device is. U-Healthcare Environment and hospital officials indiscriminately exploited by the patient's vital information, however, could threaten the patient's life problems are appearing. In this paper, depending on the level of authority, hospital officials, Union of ID-based authentication model is proposed to use a patient's vital information. Union proposed model identify different authentication system is used in hospitals that exist in various forms in a number of ID information, health / medical information sharing between hospitals without exposure to unnecessary personal information, you can be assured of the anonymity. In particular, with easy access to patient information, hospital officials about the malicious act to protect patient information to access level for the rights granted by third parties to prevent easy access.

The Application of Ryodoraku in the U-health Care System (유헬스케어(U-health Care)에서 양도락의 활용 방안)

  • Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • Objectives : The purpose of this study was to propose the utilization plan of Ryodoraku in the U-health care systems. Methods : Computerized literature searches were performed for Ryodoraku related articles using the following databases: KISS, RISS, DBPIA, NDSL from 1990 to Oct 2010. Search terms were '양도락' or 'Ryodoraku' or 'U-health'. Due to Ryodoraku coming from Japan, additional literature review(articles published by 2008) on Japanese journal of Ryodoraku medicine was done for compensation. Results : 1. Introduction of U-health : As rapid progress of population aging and strong interest in health, the demand for the traditional Korean medical service is increasing. Until now healthcare service has provided post treatment by face-to-face manner. But according to related researches, proactive treatment is resulted to be more effective for preventing diseases. Particularly, the existing healthcare services have limitations in preventing and managing chronic geriatric degenrative diseases such as metabolic syndrome, CVA, coronary heart diseases, parkinson's diseases, degenerative joint disease, spondylosis, etc., because the cause of the above is complex and even related to life habit. As the advent of ubiquitous technology, patients with the chronic geriatric degenrative diseases can improve life habit such as poor eating habits and physical inactivity without the constraints of time and space through u-healthcare service. Therefor, lots of researches for u-healthcare service focus on providing the personalized healthcare service for preventing and managing that. To cope with this situations, The concept of u-healthcare service should be adopted in the traditional korean medicine and diagnostic devices suitable for it should be also devised and developed based on traditonal korean medine. 2. Review of existing Ryodoraku related articles for applying to U-health : articles investigating feasibility applying Ryodoraku to meridian diagnosis and raising problems of it, articles providing recent research trends of Ryodoraku, Ryodoraku related articles considering usefulness for U-health, and articles confirming the repeatability and reproducity of Ryodoraku were included. Based on the review of the above Ryodoraku related articles, several application of Ryodoraku in the U-health care system. Conclusions : To make preparations for the increasing need of traditional Korean medicine due to rising morbidity rate of chronic geriatric degenerative diseases, it is necessary to appropriately apply Ryodoraku to the U-health care system. The application of Ryodoraku is as follows. 1. To use Ryodoraku additionally to the established diagnostic device of metabolic syndrome, CVA, coronary heart diseases, parkinson's diseases, degenerative joint disease, spondylosis. 2. To apply Ryodoraku to the symptoms or diseases having a tendency to be diagnosed by correlation between the affected meridian and the lesion such as headache, nuchal pain, shoulder pain, low back pain, sciatica, HNP, etc. 3. To secure the repeatability and reproducity of Ryodoraku. 4. To devise and develop Ryodoraku appliance in order to overcome the known drawbacks and to improve error of measurement.

A Feasibility Study of Constitution Discrimination Using a Measurement Device for Dynamic Friction Coefficients of the Back of a Hand (손등피부 운동 마찰계수 측정기를 이용한 체질 판별 가능성 연구)

  • Kim, Keun-Ho;Woo, Yung-Jae;Lee, Hae-Jung;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.4
    • /
    • pp.20-29
    • /
    • 2010
  • 1. Objectives Our goal is to observe the feasibility of constitution discrimination from computing quantitative roughness index from dynamic friction coefficients and their gradients with the measurement device of skin friction with 3-Axis load cell sensor. 2. Methods In the traditional Korean medicine, skin diagnosis is one of the examination methods to discriminate Sasang constitution since it was known that Tae-eumin has rough skin, and Soyangin has smooth one. It is based on the skin roughness on the back of one's hand for the discrimination. The measurement device of skin friction with 3-axis load cell sensor has been developed in order to provide quantitative skin roughness through dynamic friction coefficients. The effective interval of the coefficients is obtained from the automatic sampling algorithm to use their curvature and slope. Then, Fisher's discriminant function of them makes the discrimination. 3. Results The success rate of extracting the effective interval was about 90% and the discriminant accuracy between Tae-eumin and Soyangin was 70% and 68% for men and women, respectively. The entire methods showed the possibility to distinguish between Tae-eumin and Soyangin by using stochastic properties of roughness index, which can make the entire system to include the measurement, the computation of the roughness index and the discrimination of constitution automatical. 4. Conclusions The measurement device, the automatic sampling algorithm of dynamic friction coefficients and the constitution discrimination algorithm were developed, respectively, and their combination can become the serial and automatic procedure for quantitative and objective skin diagnosis, which mimics the movement of the Oriental medical doctors' skin diagnosis. It can be applied to healthcare as well as the diagnosis of constitution in a u-Health system soon.