• Title/Summary/Keyword: Medical and biological imaging

Search Result 437, Processing Time 0.027 seconds

MR 영상에서 확산현상에 의한 경계강조 (Edge Enhancement due to Diffusion Effect in Magnetic Resonance Imaging)

  • 홍인기;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.124-127
    • /
    • 1995
  • Due to the self-diffusion of nuclear spins, the edge of phantoms is enhanced in the magnetic resonance imaging (MRI), especially in the case of microscopy [1]. According to several published works, theory has been established that the edge enhancement is caused by the motion narrowing around bounded regions due to diffusions of nuclear spins during data acquisition. It is found, however, that the signal decreases due to the diffusion attenuation and image is distorted as edge of the image is sharpened. In this paper, we wilt investigate this signal loss during data acquisition and its effects on image, i.e., image edge enhancement due to the diffusion phenomenon. This result is new and different from the previously discussed edge enhancement due to the diffusion, namely, by motion narrowing effect or spin bouncing effect at the boundary.

  • PDF

뇌영상의 해부학적 레이블링 시스템 (Anatomical Labeling System of Human Brain Imaging)

  • 김태우;백철화
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.171-172
    • /
    • 1995
  • In this paper, an anatomical labeling system for assisting localization of region of interest on human brain imaging is represented. Model image for labeling anatomical name on the other image is Atlas. Object image to be labeled, such as CT, MR, and PET, is registered onto Atlas. And then, anatomical name for region of interest is appeared on a window by clicking mouse button on object image. The same part named anatomically on that region is labeled and drawn on object image.

  • PDF

1.0Tesla 자기공명 영상장치에서의 혈관조영기법에 관한 연구 (MR Angiography at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;김종효
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.528-532
    • /
    • 1997
  • X-Ray Angiography has been gold standard or imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique.

  • PDF

주파수 변조를 이용한 MR DANTE 고속 영상법 (DANTE Fast MR imaging Using Frequency Modulation)

  • 노용만;정성택;홍인기;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.42-44
    • /
    • 1995
  • The original DANTE sequence and its variations have limitation in excitation profile (a sinc function-like excitation) due to the finite duration of the DANTE pulsetrain. This sinc function-like selection profile excites only a small fraction of the spins in the pixel thereby results in poor signal to noise ratio (only about ${\sim}1%$ of normal MR imaging sequence). Therefore, this poor signal to noise ratio (SNR) has been the main drawback of the original DANTE sequence. To improve the signal to noise ratio, phases of individual RF pulses in the DANTE pulse train were modulated so that more spins in the object were excited ($1{\sim}3$). We have introduced a new FM (Frequency Modulation) DANTE sequence and analyzed the signal intensity and excitation profiles.

  • PDF

1.0Tesla 자기공명 영상장치에서의 분광영상기법에 관한 연구 (Spectroscopic Imaging at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.517-527
    • /
    • 1997
  • Magnetic Resonance Spectroscopic Imaging is a methodology combining the imaging and spectroscopy. It can provide the spectrum of each areas of image so that one can easily compare the spectrum of one position to another position of the image. In this study, we developed pulse sequence or the spectroscopic imaging method, RF wave forms or the saturation of water signal, computer simulations to validate our method, and confirmed the methodology with phantom experiment. Then we applied the spectroscopic method to human subject and identified a few important metabolites in in vivo. To develope a water saturating RF waveform, we used Shinnar-Le-Roux algorithm and obtained maximum phase RF waveform. With this RF pulse, it could suppress the water signal to 1:1000. The magnet is shimmed to under 1.0ppm with auto-shimming technique. The saturation bandwidth is 80Hz(2ppm). The water and fat seperation is 3.3ppm(about 140Hz at 1 Tesla magnet), the bandwidth is enough to resolve the difference. But we are more concerned about the narrow window in between the two peaks, in which the small quantity of metabolites reside. We performed the computer simulation and phantom experiments in 8*8 matrix form and showed good agreement in the image and spectrum. Finally we applied spectroscopic imaging to the brain of human subject. Only the lipid signal was shown in the periphery region which agrees with the at distribution in human head surface area. The spectrum inside the brain shows the important metabolites such as NAA, Cr/PCr, Choline. We here have shown the spectroscopic imaging which is normally done above 1.5 Tesla machine can be performed in the 1 Tesla Magnetic Resonance Imaging Unit.

  • PDF

다층의학영상의 3차원적 표현기법에 관한 연구 (Three dimension rendering techniques in multiplanar medical images)

  • 김도우;송춘희;차은종;이태수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.271-274
    • /
    • 1996
  • Shell rendering technique, which is the combined technique of surface rendering and volume rendering, was realized on workstation. By applying it to colon data acquired by CT, its validity was shown. In addition perspective projection coordinate was used for rendering the internal surface of organ and its reality was shown to be improved. This result can be use as the essential technique of virtual endoscope which is the recent hot topic in three dimensional medical imaging.

  • PDF

효율성과 정확도 향상을 위한 MR 영상에서의 뇌 외곽선 추출 기법 개발 (Development of an Extraction Method of Cortical Surfaces from MR Images for Improvement in Efficiency and Accuracy)

  • 안광옥;정현교
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.549-555
    • /
    • 2007
  • In order to study cortical properties in human, it is necessary to obtain an accurate and explicit representation of the cortical surface in individual subjects. Among many approaches, surface-based method that reconstructs a 3-D model from contour lines on cross-section images is widely used. In general, however, medical brain imaging has some problems such as the complexity of the images, non-linear gain artifacts and so on. Due these limitations, therefore, extracting anatomical structures from imaging data is very a complicated and time-consuming task. In this paper, we present an improved method for extracting contour lines of cortical surface from magnetic resonance images that simplifies procedures of a conventional method. The conventional method obtains contour lines through thinning and chain code process. On the other hand, the proposed method can extract contour lines from comparison between boundary data and labeling image without supplementary processes. The usefulness of the proposed method has been verified using brain image.

짝지어진 데이터셋을 이용한 분할-정복 U-net 기반 고화질 초음파 영상 복원 (A Divide-Conquer U-Net Based High-Quality Ultrasound Image Reconstruction Using Paired Dataset)

  • 유민하;안치영
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권3호
    • /
    • pp.118-127
    • /
    • 2024
  • Commonly deep learning methods for enhancing the quality of medical images use unpaired dataset due to the impracticality of acquiring paired dataset through commercial imaging system. In this paper, we propose a supervised learning method to enhance the quality of ultrasound images. The U-net model is designed by incorporating a divide-and-conquer approach that divides and processes an image into four parts to overcome data shortage and shorten the learning time. The proposed model is trained using paired dataset consisting of 828 pairs of low-quality and high-quality images with a resolution of 512x512 pixels obtained by varying the number of channels for the same subject. Out of a total of 828 pairs of images, 684 pairs are used as the training dataset, while the remaining 144 pairs served as the test dataset. In the test results, the average Mean Squared Error (MSE) was reduced from 87.6884 in the low-quality images to 45.5108 in the restored images. Additionally, the average Peak Signal-to-Noise Ratio (PSNR) was improved from 28.7550 to 31.8063, and the average Structural Similarity Index (SSIM) was increased from 0.4755 to 0.8511, demonstrating significant enhancements in image quality.

$^{18}F$-플루오린 표지를 위한 신개념 반응용매에서 친핵성 불소화 반응 (Nucleophilic Fluorination Reactions in Novel Reaction Media for $^{18}F$-Fluorine Labeling Method)

  • 김동욱;정환정;임석태;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.91-99
    • /
    • 2009
  • Noninvasive imaging of molecular and biological processes in living subjects with positron emission tomography(PET) provides exciting opportunities to monitor metabolism and detect diseases in humans. Measuring these processes with PET requires the preparation of specific molecular imaging probes labeled with $^{18}F$-fluorine. In this review we describe recent methods and novel trends for the introduction of $^{18}F$-fluorine into molecules which in turn are intended to serve as imaging agents for PET study. Nucleophilic $^{18}F$-fluorination of some halo- and mesyloxyalkanes to the corresponding $^{18}F$-fluoroalkanes with $^{18}F$-fluoride obtained from an $^{18}O(p,n)^{18}F$ reaction, using novel reaction media system such as an ionic liquidor tert-alcohol, has been studied as a new method for $^{18}F$-fluorine labeling. Ionic liquid method is rapid and particularly convenient because $^{18}F$-fluoride in $H_2O$ can be added directly to the reaction media, obviating the careful drying that is typically required for currently used radiofluorination methods. The nonpolar protic tert-alcohol enhances the nucleophilicity of the fluoride ion dramatically in the absence of any kind of catalyst, greatly increasing the rate of the nucleophilic fluorination and reducing formation of byproducts compared with conventional methods using dipolar aprotic solvents. The great efficacy of this method is a particular advantage in labeling radiopharmaceuticals with $^{18}F$-fluorine for PETimaging, and it is illustrated by the synthesis of $^{18}F$-fluoride radiolabeled molecular imaging probes, such as $^{18}F$-FDG, $^{18}F$-FLT, $^{18}F$-FP-CIT, and $^{18}F$-FMISO, in high yield and purity and in shorter times compared to conventional syntheses.

Synthesis of O-(3-[18F]Fluoropropyl)-L-tyrosine (L-[18F]FPT) and Its Biological Evaluation in 9L Tumor Bearing Rat

  • Moon, Byung-Seok;Kim, Sang-Wook;Lee, Tae-Sup;Ahn, Soon-Hyuk;Lee, Kyo-Chul;An, Gwang-Il;Yang, Seung-Dae;Chi, Dae-Yoon;Choi, Chang-Woon;Lim, Sang-Moo;Chun, Kwon-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권1호
    • /
    • pp.91-96
    • /
    • 2005
  • O-(3-[$^{18}$F]Fluoropropyl)-L-tyrosine (L-[$^{18}$F]FPT) was synthesized by nucleophilic radiofluorination followed by acidic hydrolysis of protective groups and evaluated with 9 L tumor bearing rat. L-[$^{18}$F]FPT is an homologue of O-(2-[$^{18}$F]fluoroethyl)-L-tyrosine (L-[$^{18}$F]FET) which recently is studied as a tracer for tumor imaging using positron emission tomography (PET). [$^{18}$F]FPT was directly prepared from the precursor of O-(3-ptoluenesulfonyloxypropyl)- N-(tert-butoxycarbonyl)-L-tyrosine methyl ester. FPT-PET image was obtained at 60 min in 9 L tumor bearing rats. The radiochemical yield of [$^{18}$F]FPT was 0-45% (decay corrected) and the radiochemical purity was more than 95% after HPLC purification. The total time elapsed for the synthesis of [$^{18}$F]FPT was 100 min from EOB (End-of-bombardment). A comparison of uptake studies between [$^{18}$F]FPT and [$^{18}$F]FET was performed. In biodistribution, [$^{18}$F]FPT showed similar pattern with [$^{18}$F]FET in various tissues, but [$^{18}$F]FPT showed low uptake in brain. Furthermore, [$^{18}$F]FPT showed higher tumor-to-brain ratio than [$^{18}$F]FET. In conclusion, [$^{18}$F]FPT seems to be more useful amino acid tracer than [$^{18}$F]FET for brain tumors imaging with PET.