• Title/Summary/Keyword: Medical and biological imaging

Search Result 439, Processing Time 0.029 seconds

A study on the development of the computerized imaging system for diagnosis and treatment plannig of orthodontics and orthognathic surgery (치아교정과 턱수술용 컴퓨터 영상분석 및 진단 시스템 개발에 관한 연구)

  • Kim, J.H.;Kim, D.Y.;Lee, W.Y.;Ha, E.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.275-276
    • /
    • 1998
  • In this paper, we present the software on the development of the computerized imaging system for diagnosis and treatment plannig of orthodontics and orthognathic surgery. Soft tissue changes followed by orthognathic surgery mainly depends on surgical movements of hard tissue. Then, the stepwise multiple regression method was used to investigate the soft tissue changes followed by hard tissue changes. As a result of this research, we were able to develop a system which diagnoses automatic X-ray images and predicts soft tissue changes after othognathic surgery.

  • PDF

Evaluation of Signal to Noise Ratio and Image of Magnetic Resonance Imaging (자기공명영상장치의 신호대 잡음비와 영상평가)

  • Yi, Y.;Oh, C.H.;Ahn, C.B.;Lee, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.169-172
    • /
    • 1996
  • In this paper, we present the evaluation of signal to noise ratio(SNR) and images of Magnetic resonance imaging system which is underdevelopement. For the evaluation of such parameters, we used two different phantoms, one for SNR and image homogeneity, and the other is for the slice thickness measurement. Further, comparison with other leading MR systems may be needed for the better image quality assessment.

  • PDF

A Study on the X-Ray Imaging using Dusl Energy Method (이중에너지 방법을 이용한 X선 영상법에 관한 연구)

  • 신동익;김종효
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.185-194
    • /
    • 1988
  • The dual-energy technique win used to separate the bone-only and tissue-only images from the conventional chest images. The equivalent thickness of the basic materials are estimated from low and high energy images of a given complex materials using the attenuation coefficient of ma serial componens. We showed that the image quality of dual-energy imaging method can be influenced by the ponlinearity and noise components of system and spectrum distributions The quantitative analysis of Calcium component was performed by dual-energy technique and it is shown that the concentration of the Calcium could be accurately estimated within 5% error range.

  • PDF

Observation of Susceptibility Change in fMRI Using SSFP Interferometry (SSFPI) Technique (핵자기 뇌기능 영상에서 SSFPI 기법을 이용한 자화율효과의 관찰)

  • Chung, J.Y.;Chung, S.C.;Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.173-176
    • /
    • 1995
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRI (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of gradient (readout) allows us to measure precession angle $\theta$ which is in turn related to the field inhomogeneity [1-3]. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRI), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are also presented.

  • PDF

A New Quadrature Breast RF Coil for MRI (새로운 자기공명영상촬영용 Quadrature Breast RF 코일)

  • Kim, S.K.;Yang, Y.J.;Lee, D.R.;Yi, Y.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography (컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발)

  • Kim, S.H.;Suh, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF

The Ultrasound Imaging of the Tissue Attenuation Parameter in Human Liver (간 조직 감쇄 계수의 초음파 영상)

  • Song, In-Chan;Kwack, Cheol-Eun;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.227-232
    • /
    • 1990
  • As a part of the study on ultrasonic tissue characterization, conventional ultrasonic imaging system is interfaced to the personal computer to acquire raw ultrasonic signal. One approach for tissue charaterization is performed using the attenuation map to the conventional images and the resulting attenuation map images are compared and inspected inside the region of interest from the viewpoint of pattern analysis. Currently, these methods are applied and modified to effectively find out the differences between the normal control and the patients with liver cirrhosis.

  • PDF

Development of radiolabelled histone deacetylase inhibitors for PET imaging study

  • Hee-Kwon Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.165-170
    • /
    • 2020
  • Histone Deacetylases (HDACs) are enzymes that have control gene expression regulation and cell state. In additions, inhibitions of HDACs are associated with growth arrest, differentiation, or apoptosis of tumor cell. Thus HDAC inhibition is one of the interesting biological targets. A variety of HDAC inhibitors has been developed by many scientists, and some of chemical structures related with HDAC inhibitors were modified to give radiolabeled HDAC inhibitors for positron emission tomography (PET) study. In this highlight review, the development of radiolabeled HDAC inhibitors for PET study are described.

An Efficient Motion Estimation and Compensation Method for Ultrasound Synthetic Aperture Imaging (초음파 합성구경 영상을 위한 효율적인 움직임 추정 및 보상 기법)

  • 김강식;황재섭;정종섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.87-99
    • /
    • 2002
  • This paper describes a method for overcoming the motion artifacts inherent in synthetic aperture(SA) imaging. based on the investigation results as to the influence of a target motion on synthetic aperture techniques. This method uses a region-based motion compensation approach in which only the axial motion is estimated and compensated for a given region of interest(ROI) under the assumption that the whole ROI moves uniformly The estimated axial motion is calculated with a crosscorrelation(CC) method at the Point where the focused signal has the maximum energy within the ROI. We also presents a method for estimating the axial motion using the autocorrelation(AC) method that is widely used to estimate average Doppler frequency Both computer simulations and in vivo experiments show that the proposed methods can improve greatly the spatial resolution and SNR of ultrasound imaging by implementing the SA techniques for two-way dynamic focusing without motion artifacts. In addition the AC-barred motion compensation method provides almost the same results as the CC-based one, but with a dramatically reduced computational complexity.