• Title/Summary/Keyword: Medical Information Standard Technology

Search Result 168, Processing Time 0.028 seconds

Effect of Self-determination Motivation on Job Engagement and the Moderating Effect of Compensation Satisfaction in Dental Hygienists (치과위생사의 자기결정성동기가 직무열의에 미치는 영향 및 보상 만족도의 조절효과)

  • Kim, Min-Jeong;Kim, Ji-Young;Ryu, See-Won
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2022
  • Purpose : The purpose of this study was two-fold: to identify the effect of dental hygienist's self-determination motivation on their job engagement and to analyze the moderating effect of compensation satisfaction that affect the relevance. Methods : Data were collected using a structured self-report questionnaire administered to 260 dental hygienists working in dental hospitals and clinics in Busan, South Korea. These were analyzed using IBM SPSS Statistics version 26.0 and SPSS Process Macro 3.5. A frequency analysis, including the respondents' general characteristics, frequency, percentages, and standard deviations, was performed. A regression analysis was also performed using SPSS Process Macro to verify the moderating effect of compensation satisfaction in the effect of self-determination motivation on job engagement. Results : The self-determination motivation of the dental hygienists had a statistically significant positive effect on their job engagement, which was the dependent variable. Higher intangible compensation satisfaction levels led to a stronger effect of intrinsic motivation but a weaker effect of extrinsic motivation on job engagement. Moreover, higher tangible compensation satisfaction levels strengthened the effect of intrinsic motivation on job engagement. Conclusion : Recently, the demand for oral health care has been increasing, Competition in the dental medical service market warrants, high-quality dental services based on accurate diagnosis and treatment. In this context, dental hygienists' job engagement must be improved. For this purpose, increasing the satisfaction of dental hygienists with self-determination motivation and appropriate compensation is effective. In addition, attention must be paid to the moderating effect of compensation satisfaction on the relationship between intrinsic motivation and job engagement. On the basis of the implications of this study, the results can be used as basic data for improving dental hygienists' welfare system and manpower management.

Analysis of Online Educational Videos for Patients with Radiation Therapy (방사선치료 환자를 위한 온라인 교육 동영상 분석)

  • Kim, Dae-Gun;Jeong, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2022
  • This study aimed to analyze educational understanding and satisfaction by survey including for the online educational videos by used online platform (YouTube) which provide resolve patient's questions, require attention and treatment information for a patient with radiation therapy. Video viewing analysis was used by YouTube studio. The survey was analyzed general properties (age, academic ability, disease, and watched of no watched videos) and educational understanding and satisfaction for two groups as no watched and watched patients. The views number was 60% at the female higher than 40% at the male. Based on the standard viewing time (hours), the non-subscription rate was 86.7%. The device type mostly used the mobile phone (82.8%). The viewership of educational videos was lower as the age increased and the academic ability decreased in the survey. The educational understanding increased by 22% at watched group as 4.15 point from at no watched group as 3.4 point (p<0.001), and the educational satisfaction increased by 15.8% at watched group as 4.25 point from at no watched group as 3.67 point (p<0.01). The correlation of understanding (r=0.761) and satisfaction (r=0.767) was high for both no watched and watched groups (p<0.01). The online educational videos increased educational understanding and satisfaction for the patient with radiation therapy. Our study could be used references data for improving the quality of medical services.

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Optimization Model for the Mixing Ratio of Coatings Based on the Design of Experiments Using Big Data Analysis (빅데이터 분석을 활용한 실험계획법 기반의 코팅제 배합비율 최적화 모형)

  • Noh, Seong Yeo;Kim, Young-Jin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.10
    • /
    • pp.383-392
    • /
    • 2014
  • The research for coatings is one of the most popular and active research in the polymer industry. For the coatings, electronics industry, medical and optical fields are growing more important. In particular, the trend is the increasing of the technical requirements for the performance and accuracy of the coatings by the development of automotive and electronic parts. In addition, the industry has a need of more intelligent and automated system in the industry is increasing by introduction of the IoT and big data analysis based on the environmental information and the context information. In this paper, we propose an optimization model for the design of experiments based coating formulation data objects using the Internet technologies and big data analytics. In this paper, the coating formulation was calculated based on the best data analysis is based on the experimental design, modify the operator with respect to the error caused based on the coating formulation used in the actual production site data and the corrected result data. Further optimization model to correct the reference value by leveraging big data analysis and Internet of things technology only existing coating formulation is applied as the reference data using a manufacturing environment and context information retrieval in color and quality, the most important factor in maintaining and was derived. Based on data obtained from an experiment and analysis is improving the accuracy of the combination data and making it possible to give a LOT shorter working hours per data. Also the data shortens the production time due to the reduction in the delivery time per treatment and It can contribute to cost reduction or the like defect rate reduced. Further, it is possible to obtain a standard data in the manufacturing process for the various models.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

The Study on Filling Factor of Radiation Shielding Lead-free Sheet Via Screen Printing Method (스크린 프린팅 공법을 통한 방사선 무연 차폐 시트에 관한 연구)

  • Kang, Sang-Sik;Jeong, Ah-Rim;Lee, Su-Min;Yang, Seung-Woo;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.713-718
    • /
    • 2018
  • In many previous studies, monte carlo simulation is used to produce lead-free shielding sheet, and the possibility of radiation shielding capability and weight reduction is presented. But it is difficult to simulation for binder and micro-pores because of In fact it does not provide sufficient information necessary for the commercialization process. Therefore, in this paper, the results of radiation shielding capability corresponding to filling factor was presented by using the screen printing method to provide information on gel-paste required for the commercialization process. In this study, the geometric setup for evaluate of radiation shielding ability was designed to comply with IEC 61331-1:2014 and KS A 4025. In addition, radiation irradiation conditions were 100 kVp filtered with 2.0 mmAl total filtration was applied according to KS A 4021 standard. In this study, Pb $1270{\mu}m$, $BaSO_4$ $3035{\mu}m$, $Bi_2O_3$ $1849{\mu}m$ and $WO_3$ $2631{\mu}m$ were analyzed based on ten value layer. Additionally, the filling factor was analyzed as $BaSO_4$ 38.6%, $Bi_2O_3$ 27.1%, $WO_3$ 30.15%. However, in the case of applying low-temperature high-pressure molding in the future, it is expected that the radiation shielding capability can be sufficiently improved by reducing the porosity while increasing the filling factor.

Prioritizing Themes Using a Delphi Survey on Patient Safety Theme Reports (환자안전 주제별 보고서의 주제 우선순위 설정: 델파이 조사를 통한 분석)

  • Park, Jeong Yun;Shin, Eun-Jung;Kim, Rhieun;Kim, Sukyeong;Park, Choon-Seon;Park, Taezoon;Choi, Yun-Kyoung;Heo, Young-Hee
    • Quality Improvement in Health Care
    • /
    • v.28 no.1
    • /
    • pp.45-54
    • /
    • 2022
  • Purpose: The study aims to identify the theme list and priority criteria of patient safety theme reports in South Korea. Methods: The survey was conducted twice, and the importance of each criterion and theme was measured on a nine-point scale using the Delphi technique by a panel of 19 patient safety experts. The criteria included severity, universality, preventability, and organizational-social impact. Descriptive statistics such as frequency, percentage, mean, standard deviation, median, and interval quartile range were used to analyze the data. Results: The parameters were assigned a weighted average of 35% for severity, 20% for universality, 30% for preventability, and 15% for organizational-social impact, respectively. The final top three rankings were surgery safety, blood transfusion safety, and medication safety. In addition to expert opinion, for the theme that is selected based on the priority ranking, one to five sub-topics can be derived from the theme based on the priority ranking, societal demands, or the yearly priority list of patient safety incidents. Conclusion: It is recommended that the official patient safety center distribute the report in the form of a summary that can be utilized nationwide at medical institutions, government institutions, and other places. Updates, as well as accumulated theme reports, will serve as the baseline data for the proposal of the system and for the policy designed to implement and improve institutions' safety practices as a standard of domestic patient safety practice guidelines.

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

A Study on the Technology Development of User-based Home Automation Service (사용자 위치기반 홈오토메이션 서비스 기술 개발에 관한 연구)

  • Lee, Jung-Gi;Lee, Yeong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.327-332
    • /
    • 2017
  • As Internet of Things (IoT) technology advances, there is a growing demand for location-based services (LBSs) to identify users' mobility and identity. The initial LBS system was mainly used to measure position information by measuring the phase of a signal transmitted from a global positioning system (GPS) satellite or by measuring distance to a satellite by tracking the code of a carrier signal. However, the use of GPS satellites is ineffective, because it is difficult to receive satellite signals indoors. Therefore, research on wireless communications systems like ultra-wide band (UWB), radio frequency identification (RFID), and ZigBee are being actively pursued for location recognition technology that can be utilized in an indoor environment. In this paper, we propose an LBS system that includes the 2.45GHz band for chirp spread spectrum (CSS), and the 3.1-10.6GHz band and the 250-750MHz bands for UWB using the IEEE 802.15.4a standard for low power-based location recognition. As a result, we confirmed that the 2.45GHz Industrial, Scientific and Medical (ISM) band RF transceiver and the ranging function can be realized in the hardware and has 0dBm output power.

Comparative Study for Basic Protocol of High Dose Ablation Therapy (고용량 방사성옥소 치료의 기본 Protocol 비교)

  • Moon, Jae-Seung;Jeong, Hee-Il;Lee, Chi-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.147-156
    • /
    • 2008
  • Purpose: All acts which are enforced from the radioactive iodine therapeutic team is a in its own way principle and provision. Therefore unification of all acts can not be appropriately. We will make the standard coherence. Materials & Methods: From 5 November, 2007 to 17 November 2007, we conducted a questionnaire survey of the nuclear medicine manager of 30 hospitals. The contents of a questionnaire is medical treatment section, patient management, prosecuting attorney section, waste management and safety supervision in about the patient and a questionnaire was drawn up in the method which selects an item. Results: 30 hospital agencies are operating purely for I-131 high dose ablation therapy. Diagnostic study and daily schedule had the difference of some. The most of education for the patients took charge of doctor and nurse. The satisfaction of education was evaluated as the high thing. The safety supervision of waste management accomplishment and Safety supervision the patient and the worker observed on the basis of atomic energy law. Conclusion: Specific standards with sufficient amount of information and practical contents should have been presented through the following data. However, it seems to be lacking in many aspects. Nevertheless, respondents rated 70.9%, which is relatively high, on the value of clinical utilization, and I am very thankful for the evaluation. For many years from now, it may seem necessary for a lot of research on the specific matters based on these data to be conducted.

  • PDF