• Title/Summary/Keyword: Medical Information Standard Technology

Search Result 165, Processing Time 0.024 seconds

Characterization of Synthetic Polyamides by MALDI-TOF Mass Spectrometry

  • Choi, Hae-Young;Choe, Eun-Kyung;Yang, Eun-Kyung;Jang, Sung-Woo;Park, Chan-Ryang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2354-2358
    • /
    • 2007
  • MALDI-TOF-MS technique was applied to obtain structural and compositional information of synthetic polyamides, Nylon6 and Nylon66. Mass spectra of both the original and the hydrolyzed polyamide samples were analyzed using the self calibration method as well as the internal calibration method with the standard materials of known masses. The MALDI-TOF mass spectra of Nylon6 samples showed the presence of protonated, sodiated, and potassiated ions that were assigned to cyclic and NH2/COOH terminated linear oligomers. From the MALDI-TOF mass spectra of Nylon66 samples, the potassiated linear oligomers with three different end groups are identified as well as the cyclic oligomers, i.e., NH2/COOH terminated oligomers, NH2/NH2 terminated oligomers, and COOH/COOH terminated oligomers. Full characterization of the molecular species and end groups present in the polyamide samples has been achieved, and also the changes in mass spectral patterns after the hydrolysis of the samples are presented.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Invasive Brain Stimulation and Legal Regulation: with a special focus on Deep Brain Stimulation (침습적 뇌자극기술과 법적 규제 - 뇌심부자극술(Deep Brain Stimulation)을 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.119-139
    • /
    • 2022
  • Brain stimulation technology that administers electrical and magnetic stimulation to a brain has shown a significant level of possibility for treating a wide range of various neurological and psychiatric disorders. Depending on its nature, the technology is defined either as invasive or non-invasive, and deep brain stimulation (DBS) is one of the most well-known invasive brain stimulation technologies. Currently categorized as grade 4 medical device in accordance with Guideline On Medical Devices And Their Grades, a Notification of Ministry of Food and Drug Safety (MFDS), the DBS has been used as a stable treatment for several diseases. At the same time, the DBS technology has recently achieved substantial advancement, encouraging active discussions for its use from various perspectives. On the contrary, debates over legal regulation related to the use of DBS has relatively been smaller in numbers. In this context, this article aims to 1) introduce the DBS technology and its safety in setting out the tone; 2) touch upon major legal issues that would potentially rise from its use for four different purposes of treatment, clinical study, areas of non-standard treatment where no other methods are available, and enhancement; and finally 3) highlight disputes concerning common emerging issues observed in the aforementioned four purposes from the viewpoint of legal responsibility and liability of using the DBS, which are benefit-risk assessment, physicians' duty of information, patients' capacity to consent, control for device, and insurance coverage.

An Experimental Study on the Effect of Supporting Vest for Musculoskeletal Disorders in Low Back (허리 근골격계질환 예방 보조 조끼의 효과에 대한 실험적 연구)

  • Kim, Yun-Jeong;Jang, Jee-Hun;Cho, Yoe-han;Jeong, Jin-Hyoung;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.219-225
    • /
    • 2020
  • With the aging population, the prevalence of musculoskeletal disorders in the elderly continues to increase. In addition, musculoskeletal disorders are the third most common social and economic loss among occupational illnesses in Workers' compensation insurance benefits as of 2015 standard and are also common among workers. In this study, a vest that can assist in the prevention and treatment of musculoskeletal disorders of the waist was produced, and it is intended to confirm the presence or absence of the effect through experiments. Diseases of the waist are closely related to core muscles. Therefore, the produced vest was made in a form that supports the core muscles. Before and after wearing the vest for effectiveness verification, the While performing 10-times of the Mackenzie exercises, a waist extension exercise, collected the EMG data of the internal oblique, Rectus abdominis, and Erector spinae, which correspond to the core muscles. The collected data were analyzed through the electromyography analysis program RM-3 to obtain RMS values for 10-times measurements of each muscle and to compare the average values. After comparing the data, to verify the significance, the technical statistical value of the measurement result was calculated and the average difference was verified through PASW ver18.0, And the paired t-test is performed on the experimental results to perform statistical processing. and Statistical processing was performed by setting the significance level to α=.05.

A Study on the difference in the sharpness of venous images between individual algorithms and combinations (개별 알고리즘과 조합 간 정맥 영상의 선명화 차이에 관한 연구)

  • Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.441-447
    • /
    • 2023
  • Intravenous infusion therapy is a standard nursing procedure in medical institutions that provides patients with drugs, fluids, blood, and nutrients into the patient's mucus. It is mainly performed and managed by nurses. Additionally, it is an injection method that injects drugs directly into the blood vessels, and is used to achieve rapid results in emergency situations, and quick and accurate effects can be expected. Even experienced nurses through education and training often make mistakes, which can not only cause discomfort to patients but also cause various problems that threaten patient safety. Various studies are being conducted to reduce the pain caused by these mistakes. This paper acquired images of veins on the back of the hands of three subjects through an image detection device and conducted a study to derive an algorithm to provide clear vein images through image processing of the collected images. To sharpen the acquired vein images, existing algorithms Histogram Equalization, CLAHE, and Unsharp Masking were selected and combined. A histogram graph was used to compare images derived by applying individual algorithms and algorithm combinations to images. The histogram graph was checked by calculating the difference between the minimum and maximum values of distributed pixels and averaging them. The algorithm combination presented in this paper was 209.1, which was higher than the average values of individual algorithms of 138.7, 132.3, and 126.2, and it was confirmed that visibility was good even in actual images.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Virtual Reality Using X3DOM (X3DOM을 이용한 가상현실)

  • Chheang, Vuthea;Ryu, Ga-Ae;Jeong, Sangkwon;Lee, Gookhwan;Yoo, Kwan-Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.165-170
    • /
    • 2017
  • Web 3D technology can be used to simulate the experiments of scientific, medical, engineering and multimedia visualization. On the web environment, 3D virtual reality can be accessed well without strictly on operating system, location and time. Virtual Reality (VR) is used to depict a three-dimensional, computer generated realistic images, sound and other sensations to replicated a real environment or an imaginary setting which can be explored and interacted with by a person. That person is immersed within virtual environment and is able to manipulate objects or perform a series of action. Virtual environment can be created with X3D which is the ISO standard for defining 3D interactive, web-based 3D content and integrating with multimedia. In this paper, we discuss about X3D VR stereo rendering scene and propose new X3D nodes for the HMD VR (head mounted display virtual reality). The proposed nodes are visualized by the web browser X3DOM of X3D.

Characteristics of noise generated during treatment in dental clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.181-188
    • /
    • 2022
  • In this paper, we proposed of the results of the noise level and appropriate conversation distance by applying the noise characteristics generated during treatment at a dental clinic to the NR-curve and PSIL. As a result of analyzing the noise characteristics during treatment at a dental clinic, it was analyzed that the noise level exceeded 60dB(A), which is the health preservation limit value caused by noise, and the noise level increased as the frequency increased. the result of evaluation applying it to the NR curve, some treatment exceeded the workplace noise standard, and as a result of analyzing the level of conversational disturbance between the worker and the patient, it is desirable to have the conversation at a distance of less than 1M for accurate communication. In order to improve the quality of medical service in dental clinic and to reduce dental fear, it is judged that soundproofing protective equipment is provided to workers, and soundproofing measures are needed for noise sources (treatment devices used in treatment) and sound sources (patients and workers).

A STUDY ON THE EFFECTS OF SCATTERING DOSE ON EYES AND THYROID FOR PANORAMAGRAPHY (Focus on TLD and PLD)

  • Jung, Yeun;Dong, Kyung-Rae;Kweon, Dae-Cheol;Dieter, Kevin;Goo, Eun-Hoe;Ahn, Se-Youn;Chung, Jae-Eun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • This study concerning the surface dose of eye and thyroid from panoramagraphy used thermoluminescent dosimeter (TLD) and photoluminescent dosimeter (PLD) to take measurements at ten hospitals in the Gwangju metropolitan area. The recommendations from ICRP 60 and ICRP 73 on the allowance standard for eye are 15 mSv and for thyroid is 1 mSv. The left eye TLD and PLD values are 0.19 mSv and 0.24 mSv respectively. The right eye TLD and PLD values are 0.23 mSv and 0.25 mSv respectively. Thyroid TLD and PLD values are 0.08 mSv and 0.25 mSv respectively and did not exceed the allowance standards(p<0.001). Also comparisons are made between TLD and PLD for each organ and PLD has higher dose measurements than TLD. There are statistically significant differences in left eye measurements and thyroid measurements (p<0.01). There is no significant difference in measurements for the right eye (p>0.05). The TLD and PLD measured dose from panoramagraphy instruments on eyes and thyroid from each hospital did not exceed the recommended dose from ICRP 60 for surface dose measurements. However, due to the probability of influence, consideration should be made for all levels of dose.

Development of Gait Monitoring System Based on 3-axis Accelerometer and Foot Pressure Sensors (3축 가속도 센서와 족압 감지 시스템을 활용한 보행 모니터링 시스템 개발)

  • Ryu, In-Hwan;Lee, Sunwoo;Jeong, Hyungi;Byun, Kihoon;Kwon, Jang-Woo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.199-206
    • /
    • 2016
  • Most Koreans walk having their toes in or out, because of their sedentary lifestyles. In addition, using smartphone while walking makes having a desirable walking posture even more difficult. The goal of this study is to make a simple system which easily analyze and inform any person his or her personal walking habit. To discriminate gait patterns, we developed a gait monitoring system using a 3-axis accelerometer and a foot pressure monitoring system. The developed system, with an accelerometer and a few pressure sensors, can acquire subject's foot pressure and how tilted his or her torso is. We analyzed the relationship between type of gate and sensor data using this information. As the result of analysis, we could find out that statistical parameters like standard deviation and root mean square are good for discriminating among torso postures, and k-nearest neighbor algorithm is good at clustering gait patterns. The developed system is expected to be applicable to medical or athletic fields at a low price.