• 제목/요약/키워드: Medical Display Application

검색결과 53건 처리시간 0.026초

Fabrication of Simple White OLED with High Color Temperature for Medical Display Applications

  • Sung, Chang-Je;Kim, Jun-Jung;Lee, Jae-Man;Choi, Hong-Seok;Han, Chang-Wook;Lee, Nam-Yang;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.489-492
    • /
    • 2009
  • We report white OLED with high color temperature based on simple stacked structure for medical display applications. White OLED was fabricated with two emitting materials of fluorescent blue dopant and phosphorescent yellow dopant. We achieved luminance efficiency of 16.2cd/A and CIE color coordinates of (0.305, 0.317) at 10mA/$cm^2$. In particular, the correlated color temperature was higher than 7,000K, enough for display applications.

  • PDF

생체신호 측정기와 스마트 디바이스를 활용한 심전도 데이터 기반의 원격진료 시스템 (The Telemedicine System based ECG Data using Bio-Signal Meter and Smart Device)

  • 김이슬;조진수
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.51-56
    • /
    • 2012
  • In this paper, we propose a telemedicine system based ECG data using a bio-signal meter and a smart device for treating faraway patients. This system is composed of a patch-shaped portable bio-signal meter, patient's smart device application, and doctor's PC software. Using these components, doctors and patients can do telemedicine. First, a patient measures his own ECG signal with a bio-signal meter and send the data to a doctor using a smart device application. Then, the doctor checks the ECG data, and make and send a diagnosis chart to web server. Likewise, doctors and patients can be offered a medical environment without time and space restraints. Applying this system to real medical system can improve the problem of low accessibility and efficiency and also can reduce medical expenses.

Application of spectral image - Present and Promise -

  • Miyake, Yoichi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1158-1159
    • /
    • 2009
  • Tri-stimulus values of CIE-XYZ and RGB values obtained by photographic film, CCD camera or scanner depend on the spectral sensitivity of imaging devices and the spectral radiant distribution of the illumination. It is important to record and reproduce the reflectance spectra of the object for true device independent color reproduction and high accurate recording of the scene. In this paper, a method to record the reflection spectra of the object is introduced and its application to spectral endoscopes is presented.

  • PDF

피부관리 애플리케이션 수용에 대한 설문조사 연구 (An Empirical Research on Skin Care Application Adoption)

  • 정은영;노주영;박동균
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.51-60
    • /
    • 2016
  • Consumers who use mobile applications for their skin care are increasing due to increasing interest in skin care and smart phone use. A survey was conducted to select popular skin care mobile applications to be installed in the smart phone targeting 1,000 men and women in South Korea who are interested in their skin care. Questioned items included skin care awareness and recognition, skin care type, and the intention of using skin health care mobile services. The respondents thought the best skin as 'Flawless skin (52.3%)'. Also, 'Skin trouble' and 'Skin aging' were their major concerns. 47.1% of the respondents used mobile skin care applications, and 56.6% intended to try new mobile skin care services. The results on interesting field of skin care showed significant difference depending on gender, marital status, and annual average household income. Moreover, the results on effort made for skin care showed significant difference depending on age, gender, and marital status. They wanted the functions such as 'Review on cosmetic products by brand (23.8%)', 'Self skincare method (16.8%)', 'Continuous monitoring service (16.2%)', 'Information on cosmetic products (13.4%)'. The result of this study would be reliable as basic material for skincare mobile service area. Further studies could be focused on developing application in accordance with needs and how it should be applied.

3차원 불균형 트리 구조를 가진 의료 영상 압축에 대한 연구 (3D Volumetric Medical Image Coding Using Unbalanced Tree)

  • 김영섭;조재훈
    • 반도체디스플레이기술학회지
    • /
    • 제5권2호
    • /
    • pp.19-25
    • /
    • 2006
  • This paper focuses on lossy medical image compression methods for medical images that operate on three-dimensional(3-D) irreversible integer wavelet transform. We offer an application of unbalanced tree structure algorithm to medical images, using a 3-D unbalanced wavelet decomposition and a 3-D unbalanced spatial dependence tree. The wavelet decomposition is accomplished with integer wavelet filters implemented with the lifting method. We have tested our encoder on volumetric medical images using different integer filters and coding unit sizes. The coding unit sizes of 16 slices save considerable dynamic memory(RAM) and coding delay from full sequence coding units used in previous works. If we allow the formation of trees of different lengths, then we can accomodate more transaxial scales than three. The encoder and decoder can then keep track of the length of the tree in which each pixel resides through the sequence of decompositions. Results show that, even with these small coding units, our algorithm with certain filters performs as well and better in lossy coding than previous coding systems using 3-D integer unbalanced wavelet transforms on volumetric medical images.

  • PDF

관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계 (Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function)

  • 이강원;박민수;유도우;양오;이창호
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

의료용 로봇 원격 응용을 위한 영상처리 시스템 개발 (The Development of Image Processing System for Medical Robot Remote Application)

  • 김주영;김중혁;김정채;김기덕;유선국
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.239-251
    • /
    • 2012
  • 본 논문에서는 원격제어가 가능한 의료용 로봇 응용을 위한 웹기반-영상처리 시스템을 구현하였다. 개발된 소프트웨어 시스템은 다양한 영상처리 모듈과 원격 제어동작 모듈로 계층적으로 구성되어 있으며, 계층적 구성은 상위계층의 복잡한 응용을 위한 확장성과 웹에서의 접근성을 만족하였다. 또한, 응용환경의 변화에 따른 처리된 영상의 표시, 전송, 저장 및 공유를 위하여 다양한 DICOM, VRML, CAD (STL) 파일형식을 지원하였다. 메시지를 기반으로 한 데이터 교환과 객체-지향 모듈과 오픈소스 기반의 소프트웨어 구성은 다양한 원격 의료 응용에 따른 다양한 요구조건에 맞는 효율적인 동적 조합이 가능할 것이다.

스마트폰과 연동한 휴대용 심전도계 (A Portable ECG System Coupled with a Smartphone)

  • 김기완;안종현;박광민
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.7-11
    • /
    • 2021
  • The electrocardiogram(ECG) and heart rates are essential for diagnosing heart disease. However, conventional portable ECG devices are possible to only measure heart rates or have limitations in how and where they are measured. In this paper, a portable ECG system in which ECG waveforms and heart rates are displayed on smartphone screens is developed. A smartphone is used as display equipment instead of a computer screen for continuous monitoring. The developed ECG system filters and amplifies detected analog ECG signals. Next, it converts the amplified analog ECG signals into digital signals, then transmits to the smartphone via Bluetooth communication. This ECG system can display and store biomedical signals on a smartphone through the application. As a result, the waveform and heart rates of the developed portable ECG system has been confirmed to be similar to those of existing medical devices.

Possibility of Using DNA Chip Technology for Diagnosis of Human Papillomavirus

  • Liu, Cui-Hua;Ma, Wen-Li;Shi, Rong;Ou, Yang-Qian;Zhang, Bao;Zheng, Wen-Ling
    • BMB Reports
    • /
    • 제36권4호
    • /
    • pp.349-353
    • /
    • 2003
  • To explore the application of DNA chip technology for the detection and typing of Human Papillomavirus (HPV), the HPV6, 11, 16 and 18 gene fragments were isolated and printed onto aminosilane-coated glass slides by a PixSys 5500 microarrayer as probes to prepare the HPV gene chips. HPV samples, after being labeled with fluorescent dye by restriction display PCR (RD-PCR) technology, were hybridized with the microarray, which was followed by scanning and analysis. The experimental condition for preparing the HPV gene chips was investigated, and the possibility of HPV genotyping using gene chips was discussed. The technique that was established in this study for preparing HPV gene chips is practical. The results of the present study demonstrated the versatility and inspiring prospect of using this technology to detect and genotype HPV.

2차원 손실 의료영상 압축

  • 김영섭
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 춘계학술대회 발표 논문집
    • /
    • pp.217-222
    • /
    • 2004
  • This paper focuses on lossy medical image compression methods for medical images that operate on two-dimensional(2D) integer wavelet transform. We offer an application of the Set Partitioning in Hierarchical Trees(SPIHT) algorithm to medical images, using a 2D wavelet decomposition and a 2D spatial dependence tree. The wavelet decomposition is accomplished with integer wavelet filters implemented with the lifting method, where careful scaling and truncations keep the integer precision small and the transform unitary. We have tested our encoder on medical images using different integer filters. Results show that our algorithm with certain filters performs as well and is sometimes better lossy coding using 2D integer wavelet transforms on medical images.

  • PDF