• 제목/요약/키워드: Median test

검색결과 725건 처리시간 0.022초

Bootstrap Median Tests for Right Censored Data

  • Park, Hyo-Il;Na, Jong-Hwa
    • Journal of the Korean Statistical Society
    • /
    • 제29권4호
    • /
    • pp.423-433
    • /
    • 2000
  • In this paper, we consider applying the bootstrap method to the median test procedures for right censored data. For doing this, we show that the median test statistics can be represented by the differences of two sampler medians. Then we review to the re-sampling methods for censored dta and propose the test procedures under the location translation assumption and Behrens-Fisher problem. Also we compare our procedures with other re-sampling method, which is so-called permutation test through an example. Finally we show the validity of bootstrap median test procedure in the appendix.

  • PDF

Median Ranked Ordering-Set Sample Test for Ordered Alternatives

  • Kim, Dong-Hee;Ock, Bong-Seak
    • Communications for Statistical Applications and Methods
    • /
    • 제15권6호
    • /
    • pp.947-957
    • /
    • 2008
  • In this paper, we consider the c-sample location problem for ordered alternatives using median ranked ordering-set samples(MROSS). We propose the test statistic using the median of samples that have the same ranked order in each cycle of ranted ordering-set sample(ROSS). We obtain the asymptotic property of the proposed test statistic and Pitman efficiency with respect to other test statistic. In simulation study, our proposed test statistic has good powers for some underlying distributions we consider.

A Note on the Median Control Chart

  • Park, Hyo-Il
    • Communications for Statistical Applications and Methods
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2013
  • This study reviews several well-known control charts for the location parameter with a discussion of the relationship between the maintenance of the control chart and a series of hypotheses testing. As a by-product, we then propose a new median control chart with the sign test statistic. We also modify the nonparametric control charts to easily understand the relation. Then we illustrate the construction of several median control charts with the industrial data and compare the efficiency among several control charts. Finally, we discuss some interesting features for the median control charts as concluding remarks.

Outlier Tests in Sample Surveys

  • Namkyung, Pyong;Lee, Joon Suk
    • Communications for Statistical Applications and Methods
    • /
    • 제7권2호
    • /
    • pp.447-456
    • /
    • 2000
  • In this paper, we considered three methods for outlier identification sample surveys. First, we studied method of handling and adjusting outliers in normal population. Second, we studied existing methods using mean, maximum and minimum and proposed a test using of median which well reflects characteristic of data regardless of sampling distribution. Finally, we showed our test using median works better than Dixon and mean test through simulation.

  • PDF

근피로 중앙주파수를 위한 AR모델의 차수결정에 관한 연구 (A Study on Order Decision of AR Model for Median Frequency in Fatiguing EMG)

  • 조은석;차샘;이기영
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권1호
    • /
    • pp.8-12
    • /
    • 2010
  • 본 연구에서는 t-test와 ANOVA를 이용하여 근전도의 중앙주파수 추출을 위한 AR모델 차수결정 및 중앙주파수 비교에 관한 연구이다. 근전도의 근피로와 관계된 특징인자인 영교차율 및 저대역에너지, 중앙주파수를 추출하여 근피로에 이를 때까지의 변화를 평가해 봄으로써 근피로 정도나 시점까지의 변화 정도를 비교 및 고찰하였다.

  • PDF

Dyssynergic Defecation in Chronically Constipated Children in Korea

  • Sun Hwan Bae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권2호
    • /
    • pp.127-133
    • /
    • 2023
  • Purpose: Dyssynergic defecation (DSD) is one of the important causes of chronic constipation in children. We aimed to analyze the clinical features, diagnostic test results, and treatments for DSD in children. Methods: Children diagnosed with DSD using fluoroscopic defecography were enrolled in this study. Clinical data, including the results of colon transit time (CTT) test and biofeedback (BF) therapy, were collected from medical records retrospectively. Results: Nineteen children were enrolled. The median age was 9 years (6-18 years), the median frequency of bowel movement was 1/7 days (1-10 days), the median duration of constipation was 7.0 years (2-18 years), the median age of onset of constipation was 2.5 years (1-11 years). In the CTT test, outlet obstruction type was noted in 10/18 (55.6%), slow transit type in 5/18 (27.8%), and normal transit in 1/18 (5.6%). The median CTT was 52 hours (40-142 hours). Initial medical therapy was performed with the polyethylene glycol 4000, and the response was good in 9/19 (47.4%), fair in 9/19 (47.4%), and poor in 1/19 (5.0%). BF was performed in 8/19, with good results in 6/8 (75.0%) children and failure in 2/8 (25.0%) children. After long-term medical therapy (11/19), 3/5 showed good response with medication alone, 6/8 showed good response with BF and medication combined. Conclusion: DSD should be considered as a cause of chronic constipation in children, especially in those with abnormal CTT test results. BF combined with medical therapy is effective even with age-limited cooperation.

영상에서 선형순위검정법을 이용한 에지검출 비교 (Comparison of Edge Detection using Linear Rank Tests in Images)

  • 임동훈
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권6호
    • /
    • pp.17-26
    • /
    • 2005
  • 본 논문에서는 통계학의 선형순위통계량(linear rank statistics)에 기초한 3가지 비모수 검정법 즉. Wilcoxon 검정법, Median 검정법 그리고 Van der Waerden 검정법을 이용하여 에지를 검출하고자 한다. 5$\times$5 윈도우상에서 중심픽셀의 에지여부는 에지-높이 모수(edge-height parameter)를 사용한 모형 하에서 두 영역간의 유의한 차이가 있는지를 검정함으로서 결정한다. 영상실험에서 통계적 방법들 간의 에지검출 성능은 에지맵(edge map)을 통한 정성적인 비교와 객관적인 척도 하에서 정량적인 비교를 통하여 분석하였다.

  • PDF

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

GT 셀 형성을 위한 효율적 Ρ-median 접근법 (Efficient Ρ-median approach to GT cell formation)

  • Won, Youkyung
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.40-43
    • /
    • 2000
  • This paper is concerned with development of an efficient Ρ-median approach applicable to large cell formation(CF) problems. A two-phase methodology that seeks to minimize the number of exceptional elements is proposed. In phase I, two efficient Ρ-median formulations which contain fewer binary variables than existing Ρ-median formulations are constructed. These make it possible to implement large CF problem within reasonable computer runtime with commercially available linear integer programming codes. Given the initial cell configuration found with the new p-median formulations, in phase II bottleneck machines and parts are reassigned to reduce the number of exceptional elements. This procedure has the flexibility to provide the cell designer with alternative solutions. Test results on large CF problems show a substantial efficiency of the new Ρ-median formulations.

  • PDF

핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석 (Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department)

  • 채홍주;천준홍;이선호;유소연;유선희;박지혜;임수연
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.51-58
    • /
    • 2019
  • 핵의학 체외 검사실 에서는 시약 Lot가 변경될 때, Lot 간의 결과가 신뢰성이 있는지를 판단하기 위해 Lot 간 동등성 검사(comparability test between reagent lots) 또는 시약 병행 검사(reagent parallel test)를 시행하는데, 다수의 국내 검사실에서는 두 lot 간 결과 차이로부터 %difference를 구하여 저농도에서는 20% 이내, 중 고농도에서는 10% 이내로 설정하고 있으며 범위를 벗어 날 경우 재검사 시행으로 범위를 맞추는 실정이다. 따라서 본원의 핵의학 체외 검사실에서 시행되는 몇 가지 검사를 선정하여 parallel test의 결과를 분석해보았고, 검사별 맞춤 %difference 값 선정에 도움 될 만한 참고 자료를 마련해 보고자 하였다. Thyroid-stimulating hormone(TSH), Free thyroxine(FT4), Carcinoembryonic antigen(CEA), CA-125, Prostate-specific antigen(PSA) 그리고 HBs-Ab, insulin, 7종목에 대해 2018 1월부터 2018년 11월까지의 기간 동안의 시약 lot 변화에 따른 정도 관리 물질의 결과를 분석하였다. TSH, F-T4, CEA, CA-125, PSA의 측정에는 IRMA의 원리를 이용한 RIA-MAT 280 system이 사용되었고, Insulin의 측정에는 TECAN 자동화 분주 장비와 GAMMA-10 측정 장비가 사용되었다. HBs-Ab의 측정에는 HAMILTON 자동화 분주 장비와 GAMMA-10 측정 장비가 사용되었다. 각각 전용 시약과 전용 칼리브레이터, 전용 정도 관리 물질이 사용되었다. 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(중농도) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [10.0 / 4.2 / 3.9 / 0.0] C-2(고농도) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(중농도) [9.6 / 4.3 / 4.3 / 0.3] C-2(고농도) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(저농도) [9.8 / 4.2 / 3.0 / 0.0] C-2(중농도) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(저농도) [15.4 / 7.6 / 8.2 / 0.0] C-2(중농도) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(중농도) [9.6 / 3.7 / 2.7 / 0.2] C-2(고농도) [8.9 / 4.1 / 3.6 / 0.3] 7. insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(중농도) [8.7 / 3.1 / 2.4 / 0.9] C-2(고농도) [8.3 / 3.2 / 1.5 / 0.1] 모두 정도 관리 물질의 lot 변경 시에도 유의미한 차이가 없었으며 표본 수가 늘어남에 따라 검사실과 검사 종목 별 맞춤 허용 기준을 설정할 수 있을 것이라 기대할 수 있었다. 면역 방사 계수 측정법에서 비교적 검출률이 높은 종목들을 선정해서 일 것이라 판단되며 여러 번 재 측정된 결과 값이기 때문일 수도 있겠다. 대부분의 검사 결과에서 허용 기준인 10%에 크게 못 미치는 차이를 보였으며 저농도 target 값을 가진 경우에도 허용 기준인 20%에 가까운 수치를 보이진 않았다. 더 오랜 기간 동안의 관찰과 연구를 통해 평균의 균질화가 이루어진다면 종목 별 검사실 맞춤 허용 기준을 얻을 수 있을 것으로 판단되며 더 다양한 변수를 고려한 관찰과 연구도 필요할 것이다.