• 제목/요약/키워드: Mechanical wear

검색결과 1,752건 처리시간 0.035초

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권2호
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

승모판에서의 표준형 이오네스류 판막의 조직실패 (Tissue Failure of the Standard-Profile lonescu-Shiley Pericardial Valve in Mitral Position)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제29권10호
    • /
    • pp.1111-1117
    • /
    • 1996
  • 표준형 이오네스큐우심낭판막의 일차성 조직실패상의 특징의 일부를 알아보고져 승모판위치에서 각 각 행콕판막을 적출하였던 56례와 표준형 이오네스큐판막을 적출하였던 연속적 전례인 일차성 조직실 패환자 113례를 대상으로 임상 및 병리학적으로 분석 검토하였다. 양 환자군의 수술당시의 연령은 각각 31.9$\pm$9.2세와 30.4$\pm$ 12.5세였다. 행콕판막은 조직손상으로 인 한 판막폐쇄부전이 빈발한 반면 이오네스큐판막은 석회화변성의 빈도가 높고 협착병변인 경향이 우세 하였다. 판막적출기간은 행콕판막에서보다 이오네스큐판막에서 단축되 었다. 이러한 판막실패의 특징은 판막구조설계의 개선으로 기계적 요소로 인한 판막실패를 감소할 수 있을 것으로 보이나 항광물화상의 개선 없이는 조직판막의 내구성의 개선은 곤난할 것임을 시사하였다.

  • PDF

불소 바니쉬가 인공 우식 병소의 발생에 미치는 영향 (EFFECT OF FLUORIDE VARNISH ON DEVELOPMENT OF ARTIFICIAL CARIES)

  • 조난주;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.613-622
    • /
    • 2007
  • 본 연구의 목적은 법랑질 시편에 수종의 불소 제재를 도포한 후 우식 예방 효과를 광밀도 및 미세경도 측정을 통해 평가하는 것이다. 소의 절치를 이용하여 80개의 법랑질 시편을 제작하고 각 군당 20개씩, 네 군으로 나누었다. I군은 대조군으로서 아무런 처치도 하지 않았고 II군은 acidulated phosphate fluoride(APF) gel(60 seconds $taste^{(R)}$, PASCAL, USA)을 4분간 적용한 후 수세하였다. III군은 Fluor $Protector^{(R)}$(Ivoclar Vivadent, Liechtenstein)를, IV군은 $CavityShield^{TM}$(Omnii Pharmaceuticals, USA)를 1분간 도포하고 증류수에 보관한 뒤 24시간 후 부드러운 모를 가진 칫솔을 이용하여 칫솔질하였다. 각 시편을 인공우식용액에 48시간동안 침잠시켜 인공우식병소를 유발한 후 광밀도를 컴퓨터 영상분석 프로그램으로 분석하고 표면미세경도를 측정하여 다음의 결과를 얻었다. 1. 광밀도는 APF gel을 도포한 II군에 비해 불소 바니쉬를 도포한 III, IV군이 높았으나(p<0.05) III군과 IV군 사이의 유의한 차이는 없었다. 2. 표면미세경도는 IV군, III군, II군, I군의 순으로 높았다(p<0.05). 3. $CavityShield^{TM}$를 도포한 IV군과 Fluor $Protector^{(R)}$를 도포한 III군은 광밀도에서는 유의한 차이가 없었으나 표면 미세경도는 IV군이 III군보다 유의하게 높았다. 이상의 결과를 종합해 볼 때 불소 바니쉬가 APF gel에 비해 법랑질 탈회 억제 효과가 우수한 것으로 나타났다. 임상적용의 용이성과 안전성을 고려할 때 불소 바니쉬의 사용이 영유아나 장애인에게 유용할 것으로 사료된다.

  • PDF

A STUDY ON MECHANICAL PROPERTIES OF TiN, ZrN AND WC COATED FILM ON THE TITANIUM ALLOY SURFACE

  • Oh, Dong-Joon;Kim, Hee-Jung;Chung, Chae-Heon
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.740-750
    • /
    • 2006
  • Statement of problems. In an attempt to reduce screw loosening, dry lubricant coatings such as pure gold or tefron have been applied to the abutment screw. However, under repeated tightening and loosening procedures, low wear resistance and adhesion strength of coating material produced free particles on the surface of abutment screw and increased frictional resistance resulting in screw tightening problems. Purpose. The aim of this study was to compare friction coefficient, adhesion strength, vickers hardness and evaluate coating surface of titanium alloy specimens coated with TiN(titanium nitride), ZrN(zirconium nitride) and WC(tungsten carbide). Material and method. Titanium alloy(Ti-6Al-4V) discs of 12mm in diameter and 1mm in thickness divided into 4 groups. TiN, ZrN and WC was coated for the specimens of 3 groups respectively, and those of 1 group were not coated. Each group was made up of 4 specimens. In this study, sputtering method was used among the PVD(Physical Vapor Deposition) techniques available for TiN, ZrN and WC coatings. Friction coefficient, adhesion strength, vickers hardness and coating surface of 4 groups were measured. Results. 1. For all three coating conditions, friction coefficient was significantly decreased. Especially, ZrN coated surface showed the lowest value. $TiN(0.39{\pm}0.02)$, $ZrN(0.24{\pm}0.01)$, $WC(0.31{\pm}0.03)$. 2. TiN coating showed the highest adhesion strength, however ZrN coating had the lowest value. $TiN(25.3N{\pm}1.6)$, $ZrN(14.8N{\pm}0.6)$, $ WC(18.4N{\pm}0.7)$. 3. Vickers hardness of all three coatings was remarkably increased as compared with that of none coated specimen. TiN coating had the highest Vickers hardness, however WC coating showed the lowest value. $TiN(1865.2{\pm}33.8)$, $ZrN(1814.4{\pm}18.6)$, $WC(1008.5{\pm}35.9)$. 4. The ZrN or WC coated specimen showed a homogeneous and smooth surface, however the rough surface with defects was observed for TiN coating. Conclusions. When TiN, ZrN and WC coating applied to the abutment screw, frictional resistance would be reduced, as a result, the greater preload and prevention of the screw loosening could be expected.

치과용 콤포짓트 레진의 수분 흡수에 따른 압축강도와 굴곡강도의 변화에 관한 연구 (A STUDY ON CHANGE OF COMPRESSIVE STRENGTH AND FLEXURAL STRENGTH OF DENTAL COMPOSITE RESIN AFTER WATER STORAGE)

  • 정내정;김정욱;이상훈
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.146-153
    • /
    • 2001
  • 콤포짓트 레진의 다양한 성분은 기계적 성질에 많은 영향을 미치고, 수복물 주위의 환경 또한 재료의 성질에 많은 영향을 줄 수 있다. 구강 내에서 수복된 콤포짓트 레진은 항상 수분에 노출되어 있고, 콤포짓트 레진의 매트릭스는 수분을 흡수할 수 있으므로, 그 결과 콤포짓트 레진은 팽창하게 된다. 또한 콤포짓트 레진의 수분 흡수가 표면강도와 마모저항의 저하와 관계된 다고 알려져 있는바 저자는 치과용 콤포짓트 레진의 수분 흡수에 따른 압축강도와 굴곡강도의 변화에 관하여 알아보고자 하였다. 재료는 1군을 Z-100(3M, U.S.A.), 2군을 Spectrum(Dentsply, U.S.A.), 3군을 Clearfil AP-X(Kuraray, Japan), 4군을 Pyramid(Bisco, U.S.A), 5군을 Heliomolar(Vivadent, Germany)로 나누어 7일, 30일, 60일, 120일간 증류수에 넣어 $37^{\circ}C$에서 보관한 후 Instron 6022(Instron, U.K.)를 이용하여 압축강도와 굴곡강도를 측정하여 다음과 같은 결과를 얻었다. 1. 7일, 30일, 60일, 120일로 기간이 증가함에 따라 모든 군에서 압축강도가 감소하였다(p<0.05). 2. 7일, 30일, 60일, 120일로 기간이 증가함에 따라 모든 군에서 굴곡강도가 감소하였다(p<0.05). 3. Hybrid type인 1, 2, 3군에 비해 matrix 비율이 높은 microfine type인 5군이 강도가 낮았다.

  • PDF

제2족지 수질부 유리피판을 이용한 수지첨부재건 치험례 (Finger Tip Reconstruction Using $2^{nd}$ Toe Pulp Free Flap - A Case Report -)

  • 박용순;홍종원;김영석;노태석;나동균
    • Archives of Reconstructive Microsurgery
    • /
    • 제19권1호
    • /
    • pp.37-45
    • /
    • 2010
  • Purpose: First introduced by Buncke and Rose in 1979, the neurovascular partial $2^{nd}$ toe pulp free tissue transfer has been attempted to reconstruct posttraumatic finger tip injuries. Although some surgeons prefer other reconstructive methods such as skin graft and local flap, we chose the partial $2^{nd}$ toe pulp flap owing to its many advantages. We report three successful surgical cases in which the patients had undergone this particular method of reconstruction. Methods: We retrospectively examined three cases of fingertip injury patients due to mechanical injury. Bone exposure was seen in all three cases, All had undergone partial toe pulp free flap for soft tissue defect coverage. Results: All flaps survived without any complications such as partial necrosis, hematoma or dehiscence. Although tingling sensation has returned in both cases, two-point discrimination has not returned yet. Currently no patient is complaining of any pain which gradually improved during their course of recuperation. All stitches were removed on postoperative 2 weeks. Patients are satisfied with the final surgical result and there are no signs of any edema or hematoma. Conclusion: The homodigital reconstruction of finger tip injury using the partial $2^{nd}$ toe pulp flap has numerous advantages compared to other reconstructive modalities such as its resistance to wear and tear and in that it provides a non-slip palmar digital surface. However it requires microsurgery which may not be preferred by surgeons. Advanced age of the patient can be a relative contraindication to this approach since atheromatous plaque from the donor toe can compromise flap circulation after surgery. We report three successful cases which patient age was considered appropriate. Further investigation with a larger number of cases and long term follow-up is deemed necessary.

  • PDF

돈사 작업장 유형에 따른 암모니아와 황화수소의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Emission Characteristics of Ammonia and Hydrogen Sulfide by Pig Building Types)

  • 김기연;박재범;김치년;이경종
    • 한국산업보건학회지
    • /
    • 제16권1호
    • /
    • pp.36-43
    • /
    • 2006
  • The principal aim of this field study was to determine the concentrations and emissions of gaseous contaminants such as ammonia and hydrogen sulfide in the different types of pig buildings in Korea and allow objective comparison between Korea and the other countries in terms of pig housing types. This field study was performed from May to June and from September to October in 2002. Pig buildings investigated in this research were selected in terms of three criteria; manure removal system, ventilation mode and growth stage of pig. Measurements of concentration and emission of ammonia and hydrogen sulfide in the pig buildings were done in 5 housing types and the visited farms were 15 sites per each housing type. Concentrations of ammonia and hydrogen sulfide were measured at three locations of the central alley in the pig building and emission rates of them were estimated by multiplying the average concentration($mg/m^3$) measured near the air outlet by the mean ventilation rate($m^3/h$) and expressed either per pig of liveweight 75kg(mg/h/pig) or per area($mg/h/m^2$). Concentrations of ammonia and hydrogen sulfide in the pig buildings were averaged to 7.5 ppm and 286.5 ppb and ranged from 0.8 to 21.4 ppm and from 45.8 to 1,235 ppb, respectively. The highest concentrations of ammonia and hydrogen sulfide were found in the mechanically ventilated buildings with slats; 12.1 ppm and 612.8 ppb, while the lowest concentrations of ammonia and hydrogen sulfide were found in the pig buildings with deep-litter bed system(2.2 ppm) and the naturally ventilated pig buildings with manure removal system by scraper(115.2 ppb), respectively(p<0.05). All the pig buildings were investigated not to exceed the threshold limit values(TLVs) of ammonia(25 ppm) and hydrogen sulfide(10 ppm). The mean emissions of ammonia and hydrogen sulfide per pig(75kg in terms of liveweight) and area($m^2$) from pig buildings were 250.2 mg/h/pig and 37.8 mg/h/pig and $336.3mg/h/m^2$ and $50.9mg/h/m^2$, respectively. The pig buildings with deep-litter bed system showed the lowest emissions of ammonia and hydrogen sulfide(p<0.05). However, the emissions of ammonia and hydrogen sulfide from the other pig buildings were not significantly different(p>0.05). Concentrations and emissions of ammonia and hydrogen sulfide were relatively higher in the pig buildings managed with deep-pit manure system with slats and mechanical ventilation mode than the different pig housing types. In order to prevent pig farm workers from adverse health effect caused by exposure to ammonia and hydrogen sulfide in pig buildings, they should wear the respirators during shift and be educated sustainably for the guideline related to occupational safety.

인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험- (The Second Animal Tests of Artificial Heart Valves)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제23권4호
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

자동차의 타이밍벨트, 등속조인트 부트, 웨더 스트립에 관련된 고장사례 고찰 (Failure Examples Study Including with timing belt, Constant Velocity Boot and Weather strip on a Car)

  • 이일권;이정호;황한섭;임하영;유창배;김영규;김추하
    • 한국가스학회지
    • /
    • 제19권1호
    • /
    • pp.6-11
    • /
    • 2015
  • 이 논문은 자동차 타이밍벨트, 등속조인트 부트, 웨더 스트립에 적용되는 고무시스템의 손상이나 내구성 약화에 대한 사례 연구를 하는 것이 목적이다. 첫 번째 사례에서는 신품의 타이밍 벨트를 교환할 때 벨트의 내구성이 떨어진 벨트를 교환하여 타이밍 벨트와 스프로킷의 마찰작용에 의해 비정상적으로 타이밍 벨트 캔버스가 마멸된 것을 확인하였다. 두 번째 사례에서는 등속 조인트에 그리스의 밀봉역할을 하는 고무 부트의 내구성이 떨어져 경화되고 갈라져 이 틈으로 그리스가 누설된 것을 확인하였다. 세 번째 사례에서는 웨더 스트립이 화학적 변화에 따른 균열로 재료 변형이 생겨 웨더 스트립 고무가 찢어졌다. 이러한 현상은 문을 닫을 때 웨더 스트립 고무를 겹쳐지게 해 운행중 외부공기가 유입되어 미세한 소음이 발생되는 것을 확인했다.따라서, 자동차에 적용되는 고무재질의 부품들의 내구성 약화나 손상으로 인한 자동차의 고장사례가 발생하지 않도록 관리하여야 한다.

수종 이원중합 레진 씨멘트의 중합률 및 세포 독성에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE DEGREE OF CONVERSION AND CYTOTOXICITY OF DUAL CURE RESIN CEMENTS)

  • 노병덕;박성호;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.33-54
    • /
    • 1995
  • The degree of conversion of composite resin was known to have influence on the mechanical properties of composite materials such as hardness, strength, wear resisitance, dimensional and color stability. Also unreacted monomer was reported to be harmful to the pulp. So the degree of conversion was a very important factor in the success of composite resin restorations. In recent, the dual cure resin cement was developed with the advocations that it could increase the curing rates in the sites where the curing ligt could not reach. Moreover many manufactors added some adhesive components in the resin cement. This study was undertaken to observe the effects of curing depth and light curing times on the degree of conversion of dual cure resin cements. CR INLAY CEMENT, DUAL CEMENT and OPTEC BOND, by the Fourier transform Infrared analysis, changing the curing depth 1mm, 2mm and 3mm, and varying the light curing time 20 seconds, 40 seconds and 80 seconds at each depth. The cytotoxicity of dual cure resin cements was tested by the in vitro MTT method using L929 cell. The results was evaluated and compared statistically. The results were obtained as follows : 1. The dual cure resin cements reavealed various degree of conversion, CR INLAY CEMENT and DUAL CEMENT had a tendency to be more reactive to the light cure and OPTEC BOND was a more chemical one. 2. CR INLAY CEMENT and DUAL CEMENT showed the lowest degree of conversion in 2 mm depth, and in 3mm depth the degree of conversion increased, which were due to the chemical cure of dual cures, but OPTEC BOND showed decreasing degree of conversion with increasing curing dept h and all experimental groups showed lower degree of conversion than CHEMICAL group which cured in dark room with no light, so the weak light-curing of dual cure resin cement prevented the chemical cure. (P<0.05) 3. CR INLAY CEMENT and DUAL CEMENT showed increasing degree of conversion in 1 mm and 3 mm, according to the increasing cure times, but in 2 mm depth the degree of conversion decreased with increasing light-curing times and OPTEC BOND showed contrary tendency, but there was no ststistical importance in the differences among the experimental group.(P>0.05) 4. The optical density by MTT assay of extractions of CR INLAY CEMENT, DUAL CEMENT and OPTEC BOND revealed no statitically important differences comparing with optical density of negative control.(P>0.05) 5. CR INLAY CEMENT showed a tendency of increaing cytotoxicity with days and DUAL CEMENT and OPTEC BOND showed higher cytotoxicity in 2 days than in 4 days, but there was no statistical importance in the differences.(P>0.05).

  • PDF