• 제목/요약/키워드: Mechanical complication

검색결과 152건 처리시간 0.023초

Narrative Review of Clinical Impact of Head-Hip Offset Following Adult Spinal Deformity Surgery

  • Sunho Kim;Seung-Jae Hyun;Jae-Koo Lee;Ki-Jeong Kim
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권2호
    • /
    • pp.137-145
    • /
    • 2024
  • In adult spinal deformity (ASD) surgery, mechanical failure (MF) has been a significant concern for spine surgeons as well as patients. Despite earnest endeavors to prevent MF, the absence of a definitive consensus persists, owing to the intricate interplay of multifarious factors associated with this complication. Previous approaches centered around global spinal alignment have yielded limited success in entirely forestalling MF. These methodologies, albeit valuable, exhibited limitations by neglecting to encompass global balance and compensatory mechanisms within their purview. In response to this concern, an in-depth comprehension of global balance and compensatory mechanisms emerges as imperative. In this discourse, the center of gravity and the gravity line are gaining attention in recent investigations pertaining to global balance. This narrative review aims to provide an overview of the global balance and a comprehensive understanding of related concepts and knowledge. Moreover, it delves into the clinical ramifications of the contemporary optimal correction paradigm to furnish an encompassing understanding of global balance and the current optimal correction strategies within the context of ASD surgery. By doing so, it endeavors to furnish spine surgeons with a guiding compass, enriching their decision-making process as they navigate the intricate terrain of ASD surgical interventions.

The impact of frenulum height on strains in maxillary denture bases

  • Cilingir, Altug;Bilhan, Hakan;Baysal, Gokhan;Sunbuloglu, Emin;Bozdag, Ergun
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.409-415
    • /
    • 2013
  • PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.

폐쇄식 흉강삽관술 후 발생한 호너 증후군 - 치험 1예 - (Horner's Syndrome: A Rare Complication of Tube Thoracostomy - A case report -)

  • 최재웅;김주현;유병수;강창현;김영태
    • Journal of Chest Surgery
    • /
    • 제43권6호
    • /
    • pp.816-819
    • /
    • 2010
  • 호너 증후군은 폐쇄식 흉강삽관술 후 발생할 수 있는 드문 합병증으로 이를 치험하여 보고하고자 한다. 17세 여자 환자로 2번째 발생한 좌측 기흉으로 폐쇄식 흉강삽관술 시행 후 수술 위해 입원하였다. 입원 후 우측 중이염 발생으로 항생제 치료 중 폐쇄식 흉강삽관술 후 3일째 흉관 삽입한 동측 동공 축동과 눈꺼풀 처짐을 증상으로 하는 호너 증후군이 발생하였고, 즉시 흉관을 2~3 cm 잡아 빼서 흉관의 위치를 교정하였다. 폐쇄식 흉강삽관술 후 5일째 기흉에 대한 낭포 절제술과 기계적 흉막 유착술을 시행하였고, 특별한 문제 없이 수술 후 7일에 퇴원하였다. 수술 후 호너 증후군으로 인한 증상은 점차 호전되었고, 2달만에 완전히 회복하였다.

하악 이부 확장술 시 나타나는 합병증의 치험례 (A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING)

  • 서충환;강경화;최문기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

승모판 치환술후 발생한 좌심실 후벽 파열 (Posterior Left Ventricular Wall Rupture After Mitral Valve Replacement)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1254-1260
    • /
    • 1992
  • Rupture of the posterior left ventricular wall following mitral valve replacement is a rare but fatal complication. Over a 10 year period from August 25 1980 to November 27 1990, we have experienced 6 such patients among 884 cases of mitral valve replacement with 4 deaths and 2 survivors. One patient had a type I rupture and another a type II rapture with the remaining four patients having suffered type III ruptures. All of the ruptures were dis covered intraoperatively enabling prompt reinstitution of the cardiopulmonary bypass and subsequent cardioplegic arrest prior to repair. Overzealous removal of calcified valve leaflets seemed to be responsible for the single type I rupture, and untethering of the so called ventricular loop appeared to be the main mechanism responsible for the type III ruptures. The single type II rupture that had occurred seemed to have been caused by inadvertent laceration of the papillary muscle with resultant rupture of the posterior LV wall at the base of the papillary muscle. Among the type III ruptures, 2 patients required intraaortic balloon pump[IABP] support only for mechanical assistance and 1 patient required both the IABP and the Biomedicus LV assist device for successfull weaning following repair of the LV rupture Another patient with a type II rupture also required the circulatory assistance of both the IABP and the bio-medicus LV assist device for weaning from the bypass. Attention to meticulous technical considerations such as avoiding over aggressive removal of heavily calcified valvular tissue, preservation of as much mural leaflet tissue and chordal stuctures as possible seemed helpful in preventing this catastrophic complication from occurring. Fusion and fibrous stricture of the chordal structures appeared particularly conducive to the type II ruptures as a result of the increased susceptibility to papillary injury during operation.

  • PDF

개심술 후 발생한 대동맥-피부 누공의 치험 1예 -1예 보고 - (The Surgical Treatment for Aorto-cutaneous Fistula after Open Heart Surgery - A case report-)

  • 김미정;김병열;신용철;김우식;정성철;송창민
    • Journal of Chest Surgery
    • /
    • 제41권4호
    • /
    • pp.516-519
    • /
    • 2008
  • 개심술 이후 발생한 대동맥 피부 누공의 합병증은 드물지만 한 번 발생하면 매우 치명적이므로 빠른 진단과 수술적 치료가 요구된다. 국립의료원에서는 대동맥 판막과 승모판막 치환술 이후 4년 8개월 동안 흉골감염이 반복되다가 갑작스런 출혈로 응급실에 내원해서 대동맥 혈관 촬영술을 통해 대동맥 피부 누공을 진단하여 응급 체외순환하에 일차 봉합만으로 더 이상의 재발없이 2년간 외래 추적 관찰 중이다.

Deep Vein Thrombosis Due to Hematoma as a Rare Complication after Femoral Arterial Catheterization

  • Kim, Minsoo;Lee, Jong-Young;Lee, Cheol Whan;Lee, Seung-Whan;Kang, Soo-Jin;Yoon, Yong Hoon;Om, Sang Yong;Kim, Young-Hak
    • Journal of Yeungnam Medical Science
    • /
    • 제30권1호
    • /
    • pp.31-35
    • /
    • 2013
  • Hematoma is quite a common complication of femoral arterial catheterization. However, to the best of our knowledge, there have been no previous studies regarding deep vein thrombosis (DVT) caused by compression of a vein due to a hematoma. We report a case of a hematoma developing after femoral arterial catheterization and causing extensive symptomatic DVT. A 59-year-old male was seen in our Emergency Department with right lower leg swelling 15 days after coronary stent implantation performed using right femoral artery access. Computed tomographic (CT) scanning revealed a large hematoma (45 mm in its longest diameter) compressing the common femoral vein and with DVT from the right external iliac vein to the popliteal vein. Due to the extensive DVT involvement, we decided to release the compressed common femoral vein by surgical evacuation of the large hematoma. However, even following evacuation of the hematoma, as the DVT did not resolve soon, further mechanical thrombectomy and catheter-directed thrombolysis were performed. Angiography then showed nearly resolved DVT, and the leg swelling was improved. The patient was discharged with the anticoagulation medication, warfarin.

중심정맥카테터 삽입의 이상위치로 발생한 편측성 흉수 1례 (A Case of Pleural Effusion after Malposition of Central Venous Catheter)

  • 김재석;김상하;이낙원;권우철;최훈;변종원;홍태원;신계철;용석중
    • Tuberculosis and Respiratory Diseases
    • /
    • 제60권6호
    • /
    • pp.690-693
    • /
    • 2006
  • 중심정맥카테터 삽입 후 생길 수 있는 드문 합병증 중에 하나인 흉수 발생은 카테터와 관련된 혈관벽의 손상을 흉수 발생의 기전으로 설명하고 있다. 저자들은 우측 쇄골하정맥으로 이어지는 이상혈관 내로 카테터가 위치한 후 혈관 파열로 인하여 발생한 흉수 1례를 경험하였기에 문헌고찰과 함께 보고하는 바이다.

Angell-Shiley 판막의 임상적 평가 (Clinical Evaluation of the Angell-Shiley Porcine Xenograft Valve)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.75-82
    • /
    • 1986
  • The use of the Angell-Shiley porcine xenograft cardiac valve was limited in number at Seoul National University Hospital chiefly because of the cessation of supply from the manufacturer, Forty-eight Angell-Shiley valves along with the 5 other mechanical or tissue valves were used in 46 patients during the period from 1977 to 1980, and a total of consecutive cases was studied for their early and long-term clinical results. The operative mortality rate was 4.3%; no death after single and 2 deaths after double valve replacement within 30 days of surgery. The 44 early survivors were followed up for a total of 171.6 patient-years and a mean of 46.8$\pm$31.1 months. Four died during the follow-up period with a linealized late mortality rate of 2.33%/patient-year. Four patients had experienced 5 episodes of thromboembolism and one died; a linealized incidence of 2.91% emboli/patient-year. A single case each had a bleeding complication related to the anticoagulants, 0.58% bleeding/patient-year, and prosthetic valve endocarditis, 0.58% endocarditis/patient-year. The clinical improvement was excellent by 70% of the survivors having no cardiac symptoms at the end of the follow-up. The actuarial survival rates were 89.9$\pm$4.9% at 5 years and 69.2$\pm$15.0% at 9 years after surgery. The probabilities of freedom from thromboembolic complication were 92.3$\pm$5.5% and 80.9$\pm$9.0% at 5 and 9 years after surgery. And, the probability of freedom from overall valve failure was 83.4$\pm$6.3% at 5 years and it declined sharply down to 55.9$\pm$22.2% at 9th year of the follow-up. These results are comparable with those in the major reports, except a more accelerated and time-related increases in valve failure after 5 or 6 years after operation with the Angell-Shiley valve. The durability of the xenograft tissue valve remains as the most important debate and the need of more durable tissue valves was also discussed.

  • PDF

A ramus cortical bone harvesting technique without bone marrow invasion

  • Jeong-Kui Ku;Min-Soo Ghim;Jung Ho Park;Dae Ho Leem
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권2호
    • /
    • pp.100-104
    • /
    • 2023
  • Autogenous bone grafts from the mandibular ramus are a known source of inadequate bone volume scenarios of the residual alveolar ridge. However, the conventional block-type harvesting technique cannot prevent bone marrow invasion, which can cause postoperative complications such as pain, swelling, and inferior alveolar nerve injury. This study aims to suggest a complication-free harvesting technique and present the results of bone grafting and donor sites. One patient received two dental implants with a complication-free harvesting technique that involves creation of ditching holes with a 1 mm round bur. Sagittal, coronal, and axial osteotomies produced grid-type cortical squares using a micro-saw and a round bur to confirm the cortical thickness. The grid-type cortical bone was harvested from the occlusal aspect, and the harvesting was extended through an additional osteotomy on the exposed and remaining cortical bone to prevent bone marrow invasion. The patient did not suffer postoperative severe pain, swelling, or numbness. After 15 months, the harvested site exhibited new cortical bone lining, and the grafted area had healed to a cortico-cancellous complex with functional loading of the implants. Our technique, grid-type cortical bone harvesting without bone marrow invasion, allowed application of autogenous bone without bone marrow invasion to achieve acceptable bone healing of the dental implants and to regenerate the harvested cortical bone.