• 제목/요약/키워드: Mechanical Filter

검색결과 905건 처리시간 0.025초

다공성 알루미나 필터 표면에 형성된 나노구조물의 형상에 따른 찢어짐에 의한 세포파쇄 특성 평가 (Evaluation of Mechanical Tearing based Cell Disruption Capability to Shape Nanostructures formed on Nanoporous Alumina Filter)

  • 이용훈;한의돈;김병희;서영호
    • 한국생산제조학회지
    • /
    • 제26권1호
    • /
    • pp.1-5
    • /
    • 2017
  • This study investigated the mechanical tearing of a cell membrane using a nanostructured alumina filter for easy and quick mechanical cell disruption. Nanostructured alumina filters were prepared by a multi-step aluminum anodizing process and nanopore etching process. Six different types of nanostructures were formed on the surface of the nanoporous alumina filters to compare the mechanical cell disruption characteristics according to the shape of the nanostructure. The prepared alumina filter was assembled in a commercial filter holder, and then, NIH3T3 fibroblast cells in a buffer solution were passed through the nanostructured alumina filter at a constant pressure. By measuring the concentration of proteins and DNA, the characteristics of mechanical cell disruption of the nanostructured alumina filter were investigated.

Chemical mechanical planarization 슬러리에 사용되는 point-of-use 필터의 평가 방법 개발 (Development of point-of-use filter evaluation method using chemical mechanical planarization slurry)

  • 장선재;아툴 쿨르카르니;김형우;김태성
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.145-150
    • /
    • 2016
  • During the chemical mechanical planarization (CMP) process, slurry that comprises abrasive particles can directly affect the CMP performance and quality. Mainly, the large particles in the slurry can generate the defects on the wafer. Thus, many kinds of filters have been used in the CMP process to remove unwanted over-sized particles. Among these filters, the point-of-use (POU) filter is used just before the slurry is supplied onto the CMP pad. In the CMP research field, analysis of the POU filter has been relatively exceptional, and previous studies have not focused on the standardized filtration efficiency (FE) or filter performance. Furthermore, conventional evaluation methods of filter performance are not appropriate for POU filters, as the POU filter is not a membrane type, but is instead a depth type roll filter. In order to accurately evaluate the POU filter, slurry FE according to particle size was measured in this study. Additionally, a CMP experiment was conducted with filtered slurry to demonstrate the effects of filtered slurry on CMP performance. Depending on the flow rate and the filter retention size, the FE according to particle size was different. When the small and large particles have different FEs, the total filtration efficiency (TFE) can still have a similar value. For this reason, there is a need to measure the FE with respect to the particle size to verify the effects of the POU filter on the CMP process.

Vibration Filter Using Vector Channel Periodic Lattice

  • Hwang, Won-Gul;Im, Hyung-Eun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2043-2051
    • /
    • 2006
  • This paper considered identification of vibration characteristics of flexible structure with vector channel periodic lattice filter. We present an algorithm for AR coefficients for the vector-channel lattice filters, and characteristic equation and transfer function are derived from these coefficients. Vibration lattice filter is then constructed from the vector channel lattice filter, and performance of this vibration filter is tested with a test signal which is a combination of many sine waves to compare the performance of scalar and vector channel lattice. Also it is applied to the cantilever data to identify properties of the system, such as natural frequencies and damping ratios, to show its performance.

하드 디스크 드라이브 회전수 변화가 내부 필터 입자 포집 성능에 미치는 영향 (Effect of HDD Rotational Speed Variation on Filtration of Particles by Recirculation Filter)

  • 이대영;박희성;유용철;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1069-1076
    • /
    • 2002
  • Contamination particles in a hard disk drive can cause serious problems including slider crash and thermal asperities. A recirculation filter is typically installed in the hard disk drive to remove the particles. Measurements and theoretical predictions of particle concentration decay with the filter are carried out for a commercially available HDD. Especially, the effect of disk rotational speed on the particle capture efficiency is investigated. Results show that filter efficiency is higher for higher disk rotational speed.

고압 대용량 인버터의 출력 과전압 억제를 위한 RC filter의 현장적용 시험에 관한 연구 (Application of the RC Filter for Suppressing the Output Overvoltage of the High-voltage Large-capacity Inverter)

  • 우명호;박영민;이세현;민병덕;서광덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.962-964
    • /
    • 2001
  • In this paper, the RC filter for mitigating the output overvoltage of the 3-level 3300V 4MW inverter is described. The descriptions on power circuit and overvoltage phenomena are presented. The output transformer which may be used to obtain the higher output voltage, makes the filter design difficult because the parameter measurements are not easy and the accuracy may be poor. So, this paper presents several preliminary results on the output overvoltage with or without transformer to investigate the overall system characteristics. Some experimental results are also provided when the designed filter is applied.

  • PDF

입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구 (Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system)

  • 정의경;노광철;박재홍;황정호
    • 한국입자에어로졸학회지
    • /
    • 제5권1호
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF

마스크 필터의 효율 최적화 및 호흡 저항 감소에 관한 연구 (A Study on Optimization of Mask Filter and Reduction in Respiratory Resistance)

  • 권세현;홍자영;정상빈;허기준;이병욱
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.103-107
    • /
    • 2016
  • We conducted experiments on mask filters. We measured filtering efficiencies of several new mask filters which were manufactured by disassembling and reassembling of one type of mask filter. New filter (A+C: combination of the first layer and the third layer of the tested mask filter) showed the highest efficiency (97.7%) with the respiratory resistance of 98 pa.

슬라이딩 모드 관측기와 적응 필터를 이용한 SPMSM 기계 파라미터 추정 (SPMSM Mechanical Parameter Estimation Using Sliding-Mode Observer and Adaptive Filter)

  • 김형우;최준영
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.33-39
    • /
    • 2019
  • We propose a mechanical parameter estimation algorithm for surface-mounted permanent magnet synchronous motors (SPMSMs) using a sliding-mode observer (SMO) and an adaptive filter. The SMO estimates system disturbances in real time, which contain the information on mechanical parameters. A desirable feature that distinguishes the proposed estimation algorithm from other existing mechanical parameter estimators is that the adaptive filter estimates electromagnetic torque to improve the estimation performance. Moreover, the SMO acts as a low-pass filter to suppress the chattering effect, which enables the smooth output signals of the SMO. We verify the mechanical parameter estimation performance for SPMSM by conducting extensive experiments for the proposed algorithm.

3차원 기동표적을 사용한 수정된 상호작용 다중모델필터의 성능 분석 (Performance Evaluation of the Modified Interacting Multiple Model Filter Using 3-D Maneuvering Target)

  • 최성린;김기철;김용식;홍금식
    • 제어로봇시스템학회논문지
    • /
    • 제7권5호
    • /
    • pp.445-453
    • /
    • 2001
  • The multiple targets tracking problem has been one of the main issues in the radar applications area in the last decade. Besides the standard Kalman filtering, various methods including the variable dimen-sion filter, input estimation filter, interacting multiple model(IMM) filter, dederated variable dimension filter with input estimation, etc., have proposed to address the tracking and sensor fusion issues. In this pa- per, two existing tracking algorithm, i.e, the IMM filter and the variable dimension filter with input estima-tion(VDIE), are combined for the purpose of improving the tracking performance for maneuvering targets. To evaluate the tracking performance of the proposed algorithm, three typical maneuvering patterns, i.e., waver, pop-up, and high-diver motions, are defined and are applied to the modified IMM filter as well as the standard IMM filter. The smaller RMS tracking errors, in position and velocity, of the modified IMM filter than the standard IMM filter are demonstrated though computer simulations.

  • PDF