DOI QR코드

DOI QR Code

Development of point-of-use filter evaluation method using chemical mechanical planarization slurry

Chemical mechanical planarization 슬러리에 사용되는 point-of-use 필터의 평가 방법 개발

  • Jang, Sunjae (School of Mechanical Engineering, Sungkyunkwan University) ;
  • Kulkarni, Atul (School of Mechanical Engineering, Sungkyunkwan University) ;
  • Kim, Hyeong-U (SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University) ;
  • Kim, Taesung (School of Mechanical Engineering, Sungkyunkwan University)
  • Received : 2016.11.13
  • Accepted : 2016.12.27
  • Published : 2016.12.31

Abstract

During the chemical mechanical planarization (CMP) process, slurry that comprises abrasive particles can directly affect the CMP performance and quality. Mainly, the large particles in the slurry can generate the defects on the wafer. Thus, many kinds of filters have been used in the CMP process to remove unwanted over-sized particles. Among these filters, the point-of-use (POU) filter is used just before the slurry is supplied onto the CMP pad. In the CMP research field, analysis of the POU filter has been relatively exceptional, and previous studies have not focused on the standardized filtration efficiency (FE) or filter performance. Furthermore, conventional evaluation methods of filter performance are not appropriate for POU filters, as the POU filter is not a membrane type, but is instead a depth type roll filter. In order to accurately evaluate the POU filter, slurry FE according to particle size was measured in this study. Additionally, a CMP experiment was conducted with filtered slurry to demonstrate the effects of filtered slurry on CMP performance. Depending on the flow rate and the filter retention size, the FE according to particle size was different. When the small and large particles have different FEs, the total filtration efficiency (TFE) can still have a similar value. For this reason, there is a need to measure the FE with respect to the particle size to verify the effects of the POU filter on the CMP process.

Keywords

References

  1. C. B. Kim, S-Y. Kim and Y-J. Seo, (2001), Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001), p91-94.
  2. H. Kim, J. C. Yang and T. Kim, (2010), Measurement of CMP Slurry Abrasive Size Distribution by Scanning Mobility Particle Sizer, Electrochem. Solid. St., 13, H137-H140 https://doi.org/10.1149/1.3299254
  3. J. C. Yang, H. Kim and T. Kim, (2010), Study of Polishing Characteristics of Monodisperse Ceria Abrasive in Chemical Mechanical Planarization, J. Electrochem. Soc., 157, H235-H240. https://doi.org/10.1149/1.3273079
  4. Komanduri, R., Lucca, D.A., and Tani, Y, (1997), Technological Advances in Fine Abrasive Processes. CIRP Annals - Manufacturing Technology, 46, 545-596. https://doi.org/10.1016/S0007-8506(07)60880-4
  5. L. C. Juang, D. H. Tseng, H. Y. Lin, C. K. Lee and T. M. Liang, (2008), Treatment of Chemical Mechanical Polishing Wastewater for Water Reuse by Ultrafiltration and Reverse Osmosis Separation Full Access, Environ. Eng. Sci. 25, 7, 1091-1098. https://doi.org/10.1089/ees.2007.0056
  6. M.R. Chang, D. J. Lee and J. Y. Lai, (2006), Coagulation and Filtration of Nanoparticles in Wastewater from Hsinchu Science‐Based Industrial Park (HSIP), Separ. Sci. Technol. 41, 1303-1311. https://doi.org/10.1080/01496390600634657
  7. Parshuram B. Zantye, (2005), Processing, reliability and integration issues in chemical mechanical planarization, Ph. D thesis, University of South Florida.
  8. R. F. Probestein, (2003), Physicochemical Hydrodynamics, second ed, John Wiley & Sons, New York.
  9. R. Lo and S.-L. Lo, (2004), A pilot plant study using ceramic membrane microfiltration, carbon adsorption and reverse osmosis to treat CMP (chemical mechanical polishing) wastewater, Water. Sci. Technol. 4, 111-118.
  10. S. Jang, A. kulkarni, H. Qin and T. Kim, (2016), Note: Evaluation of slurry particle size analyzers for chemical mechanical planarization process, Rev. Sci. Instrum. 87, 046104. https://doi.org/10.1063/1.4947461
  11. S. Jang, H. Kim, H. Qin, M. Nam, A. Kulkarni and T. Kim, (2013), Evaluation of Point‐Of‐Use (POU) Filters Performance in Chemical Mechanical Polishing Slurry Supply System, Par. Aerosol Res. 9, No.4, 261-269. https://doi.org/10.11629/jpaar.2013.9.4.261
  12. Suryadevara Babu, (2016), advances in chemical mechanical planarization (CMP), Woodhead publishing, Elsevier.
  13. S-Y. Kim, S-W. Park and Y-J. Seo, (2002), Improvements of CMP characteristics using slurry filter and high-spray bar of deionized water, J Mater. Sci-Mater. El., 13, 693-696. https://doi.org/10.1023/A:1021513601795
  14. W. C. Hinds, (1999), Aerosol Technology, John Wiley & Sons, New York, pp. 483.
  15. Y.J. Seo, S-Y. Kim, Y-O. Choi, Y-T. Oh and W. S. Lee, (2004), Effects of slurry filter size on the chemical mechanical polishing (CMP) defect density, Mater. Letters 58, 2091-2095. https://doi.org/10.1016/j.matlet.2004.01.012