• 제목/요약/키워드: Measuring performance

검색결과 3,153건 처리시간 0.032초

대전류 측정시스템에 대한 잠정적 교정절차 (Temporary calibration procedures for high-current measuring system)

  • 신영준;김익수;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.440-442
    • /
    • 2001
  • Calibration procedure of high-current measuring system has been promoted to ensure the traceability of national of international standard with the similar method of high-voltage measuring system. This paper introduces general procedure to establish the traceability and type & performance tests for current-voltage transformer, transmission system, recorder and evaluation procedure as the result of intercomparison tests performed 7 laboratories of Europe, and introduces briefly the test method of itemized list from type & performance tests. So we would apply the standard as the criteria that can be enforced temporarily in korea.

  • PDF

박용 엔진 성능 측정 시스템 개발 (Development of Performance Measuring and Analysis system for Diesel Engine)

  • 서중석;육심균;조창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.953-955
    • /
    • 1996
  • For organizing a flexible and reasonable measuring system, it is necessary that one should not only understand the process itself but also choose an adequate system. In this paper, we want to show a system of measuring and analyzing diesel engine's performance which is capable of producing a report of a certain format as well as gathering, analyzing and managing data. The system was designed by VXIbus as an all-in-one. It was also proven by a real field test through the Guam diesel power plant, which was designed and constructed by Hanjung.

  • PDF

바닥충격음 방지재의 재료강성 효과 (Effect of the Stiffness on the Performance of Impact Noise Isolation Pads of a Floor)

  • 이동훈;황윤;강문;김민배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2000
  • This paper describes the effect of the pad stiffness on the noise reduction of impact noise isolation pads of a floor. And also a new semi-experimental method for measuring the impact noise isolation capability of a pad is introduced. The impact noise isolation pads made of wire-mesh, urethane-chip and foam rubber are used for measuring the stiffness, the vibrational insulation performance and the impact noise isolation capability. The correlation between the stiffness and impact noise isolation capability of pads is theoretically reviewed, and confirmed from the experimental results. For measuring the impact noise isolation capability of only an isolation pad, a semi-experimental method proposed in this study is more effective than the reverberation room method.

  • PDF

한국형 고속전철 집전장치의 성능 계측 및 평가 (Test and Evaluation of the Pantograph for Korean High Speed Train)

  • 서승일;박춘수;조용현;최강윤;목진용
    • 한국철도학회논문집
    • /
    • 제6권2호
    • /
    • pp.94-99
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, test and evaluation of the current collection performance of the pantograph is conducted. For this purpose, a measuring system is developed and installed on the prototype high speed train. Measurement is conducted while the train runs on the test track. The measuring system is composed of video monitoring system and telemetry & data processing system. It monitors the hazard behavior of the pantograph and measures acceleration and vertical force of the pan head. By applying the measuring system, accurate evaluation of the performance of the pantograph and safety assessment of the interface system of pantograph and catenary is facilitated.

서울지역 미세먼지의 실시간 고해상도 모니터링 방안 (Real-time High Resolution PM Monitoring in Seoul)

  • 강두수;봉춘근;김대성
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

포괄적인 정보시스템 성과평가모형에 관한 연구 (A Comprehensive Model for Measuring Information Systems Performance)

  • 안봉근;주기중;권해익
    • 경영과학
    • /
    • 제21권2호
    • /
    • pp.111-122
    • /
    • 2004
  • Measuring performance of corporate information system has become one of the core issues in that development of the information system requires substantial amount of investments and the system works as a crucial leverage to enhance competitive edge. Most of the previous researches for performance of the information system have narrow and limited focus on such as the effect of user satisfaction and productivity. This paper suggests a model to measures the comprehensive performance which is classified as user scope (user involvement and satisfaction), operational scope (task productivity, task innovation, customer satisfaction, management control) and efficiency scope (financial performance), and to represent the relationship among the scopes by the path analysis model. Followings are conclusions from statistical hypothesis test of the model: (i) user involvement through user satisfaction has positive effect on all the performances in the operational scope, (ii) task innovation and customer satisfaction in the operational scope has statistically significant impact on financial performance but task productivity and management control do not. This conclusion indicates that task productivity and management control has the long term effect in nature, and evaluation of the information system has managerial implication when it Is measured in comprehensive performance which includes internal operational performances as well as financial performance.

연구인력의 능력지수 개발 및 측정 사례연구 : 한국전자통신연구원 사례를 중심으로 (Measuring the Capabilities of R & D Personnel : ETRI Case)

  • 유진호;배문식;백의선
    • 기술혁신학회지
    • /
    • 제1권2호
    • /
    • pp.220-230
    • /
    • 1998
  • Recent concerns over national and corporate competitiveness have stimulated a renewed interest in organization's performance. The organization's performance primarily depends on resources including human resources, budget, physical based resources, and so on. Especially because the relationship between organization's performance ;md individual capabilities is more evident in R & D organizations where the knowledge base is embodied in people, there has taken an increasing interest in the methodologies for measuring the capabilities of R & D personnel. This paper presents new methodological approach to measure the capabilities of R & D personnel. And the model is empirically applied to ETRI, a public R & D organization in Korea. On the basis of the results, the implications for R & D management are discussed, with regard to R & D business and human resources management.

  • PDF

선박탑재용 종합내항성능 평가시스템 개발을 위한 기초적 연구 (A basic study for the development of Integrated Seakeeping Performance Evaluation System on board the ship)

  • 조익순;이충로;김순갑
    • 한국항해학회지
    • /
    • 제24권3호
    • /
    • pp.103-111
    • /
    • 2000
  • From a ship's safe operation point of view, it is very important to estimate the navigational safety in a seaway. The seakeeping performance can be defined as the ability of a ship to go to sea, and to accomplish its missions successfully and safely even in adverse environmental conditions. There are several factors presently adopted for evaluating seakeeping performance. But a hardware of the system considering all these factors has not been developed since some of them can not be measured by sensors. In this paper, a synthetic method of evaluating navigational safety is developed by measuring the vertical and lateral acceleration. An experiment by using real measuring carried out on board the T/S 'HANNARA' The equipment was measured every 4 hours for more than 30 minutes the acceleration by accelerometer, analyzed its acceleration values and calculated navigational dangerousness. As the results of this on board experiment, the system is carried conviction to be useful as evaluating seakeeping performance.

  • PDF

보호용 CT의 과도 성능 검증에 관한 연구 (A Study on the Determination of the Transient Performance for Protective Current Transformer)

  • 김동수;박남옥;김철환;류재남
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1727-1732
    • /
    • 2010
  • The Current transformer is classified measuring CT and protective CT for their purpose. The measuring CT is required to retain a specified accuracy over the normal range of load currents, but the protective CT must be capable of providing an adequate output over wide range of fault condition. Therefore, the protective CT must determine the transient performance during fault condition. This paper measured peak instantaneous error of the TPY class CT to determine the transient performance directly and indirectly and studied the test results.

접지전류 측정에 의한 다중 접지계통의 접지저항 측정 (Measurement of Resistance of Multi-Grounded System by Ground Current Measurement)

  • 최종기;안용호;정길조;한병성;김경철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.