• Title/Summary/Keyword: Measuring methods

Search Result 4,498, Processing Time 0.034 seconds

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

The Effect of Glutathione on High Dose Cisplatin-Induced Cellular Toxicity in Non-small Cell Lung Cancer Cell Lines (비소세포폐암 세포주에서 고용량 Cisplatin 세포독성에 대한 Glutathione의 효과)

  • Lee, Seung-Il;Boo, Gwi-Beom;Jang, Dai-Yong;Chung, Ki-Young;Seo, Jeoung-Gyun;Lee, Byeong-Lai;Chung, Jong-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.5
    • /
    • pp.463-474
    • /
    • 2002
  • Background : This study was designed to examine how glutathione, one of the nucleophilic sulfur compounds, effects the cisplatin cellular toxicity in the non-small cell lung cancer cell lines and normal lung epithelial cell line. Materials and Methods : Three cultured cell lines, the lung adenocarcinoma cell(NCL-H23), the lung squamous carcinoma cell(SK-MES-1) and the normal lung epithelial cell(L-132) line were exposed to various concentrations of cisplatin with or without glutathione. The relative viability was estimated as a means of measuring the cisplatin cellular toxicity using the MTT method. Results : In NCI-23, the response to cisplatin was sensitive but glutathione markedly increased the relative survival of the tumor cells by removing the antitumor effect of cisplatin. In both SK-MES-1 and L-132, the responses to cisplatin were less sensitive, and the chemoprotective effect of glutathione compared to and equal cisplatin dose was significantly higher in L-132 than in SK-MES-1(p<0.05). Conclusion : The protective effectes of of glutathione on cisplatin-induced cellular toxicity is more significant in normal lung epithelial cells than in squamous carcinoma cells.

The Correlation of Dyspnea and Radiologic Quantity in Patients with COPD (만성폐쇄성폐질환 환자에서 호흡곤란과 영상학적 정량과의 상관관계)

  • Jung, Eun Jung;Kim, Yang Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong Hoon;Kim, Do Jin;Park, Choon Sik;Hwang, Jung Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.288-294
    • /
    • 2009
  • Background: A lung hyperinflation, or air trapping, caused by expiratory flow-limitation contributes to dyspnea in patients with chronic obstructive pulmonary disease (COPD). Forced expiratory volume in 1 second ($FEV_1$) has served as an important diagnostic measurement of COPD, but does not correlate with patient-centered outcomes such as dyspnea. Therefore, this study was performed to investigate the role of radiologic quantity in evaluating the dyspnea in patients with COPD by measuring lung hyperinflation in chest x-ray and high resolution chest tomography (HRCT). Methods: Fifty patients with COPD were enrolled in this study. Their subjective dyspnea score (modified Borg scale dyspnea index), spirometry, and lung volume were measured. Simultaneous hyperinflations of chest x-ray score ("chest score") and degree of emphysema of HRCT ("HRCT score") were measured. The "chest score" were composed of lung length, retrosternal space width, and height of the arc of the diaphragm and "HRCT score" were composed of severity and extent of emphysema. Results: The mean age of patients was 69 years old and their mean $FEV_1$ was 51.7%. The Borg score significantly correlated with parameters of spirometry and lung volume, including FVC, $FEV_1$, $FEV_1$/FVC, RV, RV/TLC, and DLCO. The Borg score correlated well with "HRCT score", but did not correlate with "chest score". Also, the Borg scale correlates inversely with body mass index. Conclusion: The quantity of emphysema on chest HRCT may serve as an objective marker of dyspnea in patients with COPD.

Correlation between Expiratory Increase of Lung Attenuation and Age and Smoking in the Subjects with Normal Inspiratory Low Dose CT and Pulmonary Function Test (저선량 흉부전산화단층촬영의 흡기 영상과 폐기능이 정상인 성인에서 호기 말 폐 감쇄도 증가 정도와 연령 및 흡연과의 연관성)

  • Kwon, Sung-Youn;Hwang, Yong-Il;Yoon, Ho-Il;Lee, Jae-Ho;Lee, Choon-Taek;Lee, Kyung Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.457-463
    • /
    • 2008
  • Background: The attenuation of the lung parenchyma increases on expiration as a consequence of decreased air in the lung. Expiratory CT scans have been used to show air trapping in patients with chronic airway disease and diffuse parenchymal disease and also in asymptomatic smokers. Although there have been several reports investigating the regional air trapping on a expiratory CT scan, there have been only a few reports evaluating the changes of whole lung attenuation with considering its clinical significance, and especially in healthy subjects. The purpose of this study was to evaluate the correlation of an expiratory increase of lung attenuation with age and smoking in healthy subjects. Methods: Asymptomatic subjects who underwent a low dose chest CT scan as part of a routine check-up and who showed normal spirometry and a normal inspiratory CT scan were recruited for this study. We excluded the subjects with significant regional air trapping seen on their expiratory CT scan. Lung attenuation was measured at 24 points of both the inspiratory and expiratory CT scans, respectively, for 100 subjects. The correlations between an expiratory increase of the lung attenuation and the amount of smoking, the patient's age and the results of spirometric test were assessed. Results: There were 87 men and 13 women included in this study. Their median age was 49.0 years old (range:25~71). Sixty current smokers, 24 ex-smokers and 16 non-smokers were included. As age increased, the expiratory increase of lung attenuation was reduced at every measuring points (r=-0.297~-0.487, Pearson correlation). The statistical significance was maintained after controlling for the effect of smoking. Smoking was associated with a reduction of the expiratory increase of lung attenuation. But the significance was reduced after controlling for the patient's age. The $FEV_1$, FVC, $FEV_1/FVC$ and $FEF_{25{\sim}75%}$ were not associated with an expiratory increase of lung attenuation. Conclusion: The expiratory increase of lung attenuation in subjects with a normal inspiratory CT scan was negatively correlated with age. It was also reduced in heavy smokers. It may reflect aging and the smoking related changes.

Development and Evaluation of a Community Staged Education Program for the Cardiocerebrovascular Disease High-risk Patients (심뇌혈관질환 고위험군을 위한 지역사회 단계별 교육프로그램 개발 및 효과 평가)

  • Lee, Hye-Jin;Lee, Jung-Jeung;Hwang, Tae-Yoon;Kam, Sin
    • Journal of agricultural medicine and community health
    • /
    • v.37 no.3
    • /
    • pp.167-180
    • /
    • 2012
  • Objective: This study was conducted to evaluate an education program for cardiocerebrovascular high-risk patients. Methods: This program was developed according to Tyler's model for curriculum development. To evaluate the effects of this program, we measured clinical outcome change (weight, waist circumference, systolic blood pressure, diastolic blood pressure) and behavior change stages (checking blood pressure, blood sugar levels, doing physical activity, consistent maintenance of food intake, eating low amounts of salt, abstention from tobacco and alcohol) before and 4 weeks after participation in the education program. The group of subjects consisted of High-risk group patients who attended basic program(32 patients), and staged program(37 patients) during KHyDDI meetings from Oct. 2009 to May 2010. Results: The staged educational program was developed three aspects(disease, nutrition and exercise)and three stages(basic, in-depth and individual education). In the staged education program, the evaluations were made by measuring clinical outcome and stage of behavior before and after education. Significant differences were found in waist circumference, systolic blood pressure, diastolic blood pressure, consistent maintenance of food intake(p<0.05), and eating low salt(p<0.001)and their self efficacy. Conclusion: In the practice-oriented staged education program, significant differences were found in the clinical outcomes and stage of behavior before and after education. Possible limitations of the study include the small number of participating subjects and the short follow-up management period, but the results indicate that continued application of this program could contribute to the prevention of cardiocerebrovascular diseases for the elderly patients with long periods of chronic diseases.

Influence of bone loss pattern on stress distribution in bone and implant: 3D-FEA study (주변 골흡수 양상에 따른 임플란트와 골의 응력분산에 관한 유한요소 분석)

  • Lee, Jong-Hyuk;Kim, Sung-Hun;Lee, Jae-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This 3D-FEA study was performed to investigate the influence of marginal bone loss pattern around the implant to the stress distribution. Material and methods: From the right second premolar to the right second molar of the mandible was modeled according to the CT data of a dentate patient. Teeth were removed and an implant ($\Phi\;4.0{\times}10.0mm$) was placed in the first molar area. Twelve bone models were created; Studied bone loss conditions were horizontal bone loss and vertical bone loss, assumed bone loss patterns during biologic width formation, and pathologic vertical bone loss with or without cortification. Axial, buccolingual, and oblique force was applied independently to the center of the implant crown. The Maximum von Mises stress value and stress contour was observed and von Mises stresses at the measuring points were recorded. Results: The stress distribution patterns were similar in the non-resorption and horizontal resorption models, but differed from those in the vertical resorption models. Models assuming biologic width formation showed altered stress distribution, and weak bone to implant at the implant neck area seams accelerates stress generation. In case of vertical bone resorption, contact of cortical bone to the implant may positively affect the stress distribution.

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia (실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향)

  • Shin, Myoung-Sik;Lee, Jeong-Yol;Kim, Min-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the effect of applying Silano-pen to feldspathic porcelain and zirconia on shear bond strength with composite resin. Materials and methods: Feldspathic porcelain and zirconia specimens were produced into 30 per each 2 mm thick and 12 mm in diameter and their surface was made smooth and even and then embedded in acrylic resin. The specimens were divided into each Group F (Feldspathic porcelain) and Group Z (Zirconia), (1) Hydrofluoric acid etching and silane (F1 & Z1), (2) Silano-pen and silane (F2 & Z2), (3) Hydrofluoric acid etching and Silano-pen, silane (F3 & Z3). After surface conditioning, substrate surfaces of the specimen were examined by SEM. Composite resin cylinders (2 mm high, 3 mm in diameter)were bonded to specimen and shear bond strength between ceramic and composite resin was measured by using universal testing machine. The measured values were statistically analyzed by using two way ANOVA and Tukey's multiple comparison test (${\alpha}=.05$). Results: In the scanning electron micrograph of the treated ceramic surface, Group F2 and F3 appeared the high roughness and Group Z3 appeared the highest density of silica particle. In Feldspathic porcelain, the result of measuring shear bond strength showed that Group F3 was measured to be highest and Group F1 was measured to be lowest but there was no statistical significance among Groups. In zirconia, Group Z3 was measured to be highest and Group Z1 was measured to be lowest and there was statistical significance among Groups (P<.05). Conclusion: In zirconia, applying hydrofluoric acid etching and then Silano-pen and silane is effective for composite resin adhesion.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.