• Title/Summary/Keyword: Measuring methods

Search Result 4,500, Processing Time 0.049 seconds

The Physiological Responses and Behavior Characteristics of Sensory Stimulation of ADHD Children: A Systematic Review (ADHD아동의 감각자극에 대한 생리학적 반응 특성과 행동학적 특성: 체계적 고찰)

  • Lee, Na-Hael;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.2
    • /
    • pp.51-60
    • /
    • 2011
  • Objective : The characteristics of physiological responses of ADHD children to sensory stimulation were examined by types of sensory stimulation, measurement tools, and responses. In addition the behavioral characteristics were examined by analyzing items of common problems according to the measuring tool, frequency, and measurement tools. Methods : A systematic review methods were used. Papers published in the Journal between January, 1990 and December 31, 2011 were searched through Riss4U, MEDLINE /PubMed, CINAH. The main terms searched were "ADHD, Children, Sensory processing, Sensory integration, SP, SSP, SOR, TIE, CSP, SEP, EDR", and 15 papers were analyzed. Results : 1. The number of studies on physiological responses of children with ADHD to sensory stimulation was five (33.33 percent), the number of studies on behavioral responses was ten(66.67%), and the number of studies combined the two kinds of study was two (13.33%), where a total of 15 (100%) papers were analyzed. 2. In five studies on the physiological response, there were three studies using tactile and proprioceptive stimulations and two studies using olfactory, auditory, visual, tactile, and vestibular sensories. 3. In ten studies on the behavioral responses, there were five studies using SP, three studies using SSP, two studies using SOR, one study using TIE, and one study using CSP. Conclusion : In the characteristics of physiological responses of children with ADHD children to sensory stimulation, there was in the action potential of the cells in hand region of the primary sensorimotor cortex neurons. It was analyzed that there was an initial state and it appeared show a obvious and fast habituation in the later state; the time of recovery seemed to have many non-specific responses. In the characteristics of behavioral responses, there were inattention / distraction, vestibular processing, sensory processing related to endurance / tone, modulation of sensory input affecting emotional responses, low energy/weak.

  • PDF

Usefulness of $^{99m}Tc$-MDP Bone Scintigraphy for Assessing Vascular Ingrowth on Hydroxyapatite Ocular Implant ($^{99m}Tc$-MDP 골신티그라피를 이용한 Hydroxyapatite 안구 보충물의 혈관 신생 평가 및 임상적 유용성)

  • Kang, Bong-Joo;Sohn, Hyung-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.484-492
    • /
    • 1999
  • Purpose: This study was to evaluate the clinical usefulness of $^{99m}Tc$-MDP bone scintigraphy for assessing vascular ingrowth into the ocular implants after enucleation or evisceration. Materials and Methods: Twenty-four patients (M:F=7:17, mean age: 36 years), who buried a coralline hydroxyapatite after uncomplicated enucleation or evisceration surgery were studied. Dynamic and static scintigraphy on the orbit fossa were obtained after injection of 740 MBq $^{99m}Tc$-MDP to evaluate the status of vascularization. The study was performed from the 3 to 33 weeks after surgery. According to the visual analysis, activity greater than nasal bridge was graded as 4, equal to the nasal bridge as 3, less than nasal bridge but greater than normal orbit as 2, greater than normal orbit but less than grade 2 as 1. Uptake ratio was also calculated by measuring the implants activity (H) and contralateral orbit activity (N). Grading score and uptake ratio were compared with clinical outcome of vascularization. Additionally, we also analyzed the vascularization status as time lapse between primary surgery and scintigraphic study and surgical methods. Results: Twenty-one patients who had bone scintigraphy at 11 weeks after surgery showed increased uptake above grade 2 and greater H/N ratio than 1.16. Of these, 19 patients who had drilling surgery for permanent peg application showed adequate bleeding during the procedure. The activity grade and uptake ratio were inversely correlated with vascular ingrowth. Higher than grade 2 or greater than 1.56 in H/N ratio seemed to be an indicator for better prognosis. Accomplishment of vascularization was not affected by the surgical way such as enucleation or evisceration. Conclusion: $^{99m}Tc$-MDP bone scintigraphy can be a useful method to evaluate the vascularized status of implants. Adequate time for $^{99m}Tc$-MDP bone scintigraphy may be 11-20 weeks after enucleation or evisceration.

  • PDF

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

A Study on the documentary characteristics of acupuncture and moxibustion recorded in Dusagyeong(杜思敬)'s "Jesaengbalsu(濟生拔粹)" (두사경(杜思敬)의 "제생발수(濟生拔粹)"에 수록된 침구의적(鍼灸醫籍)에 관한 문헌)

  • Kim, Jung-Ho;Kim, Ki-Wook;Park, Hyun-Guk
    • Journal of Korean Medical classics
    • /
    • v.22 no.2
    • /
    • pp.71-83
    • /
    • 2009
  • The documentary characteristics of acupuncture and moxibustion recorded in Dusagyeong(杜思敬)'s".Jesaengbalsu(濟生拔粹)" can be summarized into 3 major parts: 1. "Gyeolgo-ungichimbeop(潔古雲岐鍼法)" and "Dutaesachimbeop(竇太師鍼法)" 1) "Gyeolgo-ungichimbeop" was edited by Dusagyeong of the Won dynasty, and was recorded in "Jesaengbalsu". Du was influenced by his teacher Heohyeong(許衡) and followed Janggyeolgo(張潔古) and his son Jangbyeok(張璧), and collected his work "Chimgu-pyeon(鍼灸篇)" for Jang and named it "Gyeolgo-ungichimbeop", and took the content from the medical book of Jang and his student Wang-haejang(王海藏). (2) "Jesaengbalsu"'s original edition exists today. The "Gyeolgo-ungichimbeop" listed in "Jesaengbalsu"'s index contain two collections, the first collection being "Gyeolgo-ungichimbeop" and the second collection being "Dutaesachimbeop(竇太師鍼法)" (3) Gyeolgo(潔古)、Un-gija(雲岐子)'s acupuncture methods can be seen in Un-gija "Bomyeongjipryuyo(保命集類要)" and Wanghaejang "Chasananji(此事難知)". (4) The related acupuncture methods are 'Non-gyeong-rak-yeongsubosabeop(論經絡迎隨補瀉法)', 'Gyeong-rakchwiwonbeop(經絡取原法)', 'Jeopgyeongbeop(接經法)', and 'Sang-hanyeolbyeongjabeop(傷寒熱病刺法)' (5) Du's edition of the entire text of 'Gyeolgojajetongbeop(潔古刺諸痛法)' 'Jasimtongjehyeol(刺心痛諸穴)' and the first half of 'Jeopgyeongbeop(接經法)' is all recorded in "Somunbyeonggigi-uibomyeongjip(素問病機氣宜保命集)". The existing "Somunbyeonggigi-uibomyeongjip" is a combination of the unfinished posthumous work of Yuwanso(劉完素), "Gi-ui(氣宜)" and "Byeonggi(病機)" with works such as Jangwonso(張元素)'s '"Bomyeongseo(保命書)"'. (6) Of the titles "Gyeolgo-ungichimbeop" and "Dutaesachimbeop", the 14$\sim$19th chapters "Dutaesachimbeop" should be concentrated at the end of the chapter, and the 16th chapter that Du added was put after chapter 14 "Yujujiyobu(流注指要賦)", and chapters 20, 21 should be put in "Gyeolgoungichimbeop" after chapter 13. 2. "Chimgyeongjeok-yeongjip(鍼經摘英集)" (1) "Chimgyeongjeok-yeongjip" is a collection of the acupuncture and moxibustion contents of medical books from the Geum and Won dynasties that Dusagyeong collected and organized during the Won dynasty, which is consisted of 5 chapters : "Guchimshik(九鍼式)", "Jeolyangchwisuhyeolbeop(折量取腧穴法)", "Bosabeop(補瀉法)", "Yongchimhoheupbeop(用鍼呼吸法)", "Chibyeongjik-ralgyeol(治病直剌訣)". (2) First, the contents. The nine acupuncture needles[九鍼] listed in "Guchimshik(九鍼式)" is the first existing document recording to systematically illustrate the 'nine classical needles' in drawing and text form which reflects the forms of the needles of the era. Second, "Jeolyangchwisuhyeolbeop(折量取腧穴法)" has the same basic way of measuring points [量穴法] as Wang-yuil's "Dong-insuhyeolchimgudo-gyeong(銅人腧穴鍼灸圖經)" and the same point selection rules as "Jeonyeongbang(全嬰方)". Third, in "Bosabeop(補瀉法)", "Somun(素問)" and Janggyeolgo's "Yeongsubosabeop(迎隨補瀉法)" is put together. Fourth, in "Yongchimhoheupbeop(用鍼呼吸法)", the cold and heat supplementation and draining [寒熱補瀉] method that combines breathing with inner and outer rotation[外 內撚] is recorded. Fifth, "Chi-byeongjik-ralgyeol(治病直剌訣)" is the main part of "Chimgyeongjeok-yeongjip(鍼經摘英集)" listing 69 acupuncture treatments reflecting Du's scholastic ideas on aspects such as syndrome differentiation[辨證], needling method and type of needle[鍼具]. (3) The content of this book was quoted by "Bojebang Chimgumun(普濟方 鍼灸門)" and when Gomu compiled "Chimguchwiyeong", he put the acupuncture treatments for the main indications of the disease patterns[鍼方主治病證] of this book in the related main indications of acupuncture points[腧穴主治證], which influenced books on acupuncture points there after. 3. "Chimgyeongjeolyo(鍼經節要)" (1) Consists of 1 volume. The original title of this book is "Dong-insuhyeolchimgudo-gyeong (銅人腧穴鍼灸圖經)" and the author is Wang-yuil of the Northern Song dynasty, written in the 4th year of the Cheonseong(天聖) era of the Song dynasty(1026). (2) Dusagyeong selected the contents on pathology of the 12 meridians in volume one and two, the introduction and five transport points[五輸穴] in volume 5 of "Dong-indo-gyeong(銅人圖經)" and named it "Chimgyeongjeolyo." During the Won dynasty it was recorded in "Jesaengbalsu".

  • PDF

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Landscape Assessment and Improvement of the View Area by Selecting the Landscape Control Point (조망점 선정을 통한 대상지의 경관가치 평가 및 개선방안)

  • Kim, Jin-Hyo;Lee, Hyun-Taek;Ra, Jung-Hwa;Cho, Hyun-Ju;SaGong, Jung-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.19-32
    • /
    • 2012
  • The purpose of this study is to quantitatively measure the view target and the view area through the selection of landscape control point by selecting Jimyeong-dong Dong-gu and Yeongyeong-dong Buk-gu Daegu, which are planned as the large scale housing complex development area, as the target places. It is very meaningful that from the simulation based on this measurement, the improvement methods are attempted to be suggested at the project level. The results of this study are as follows. First, the total number of viewing targets derived from the literature analysis for the selection of the viewing targets was 24, and finally derived main viewing targets were 4 places. Second, the total number of selection criteria of the derived landscape control point was 15, and these were re-categorized as prospect, accessibility and publicness according to the common property. The preliminary LCPs were selected by measuring the publicness and accessibility, and because of the said measurement, a total of 43 preliminary LCPs were selected. The final LCPs were selected by estimating the prospect of the selected preliminary LCPs, and as a result of estimation, a total of 29 final LCPs were selected. Finally, the total number of evaluation indicators derived from literature analysis was 26. Because of the valuation by the landscape control point, it was found that the 2 view areas were the I grade, 3 areas were II grade and 3 areas were the V grade, the lowest grade among 29 view areas. From the analysis on problems for the improvement methods, 4 improvement-indicators including the diversity of land mosaic were selected for the view area-1 without considering the development project drawing. In addition, for the view area-2 with considering the development project drawing, the landscape as the scenery forests was well formed, and the arrangement of architectures for the security of view corridor was right angle arrangement, and their floor number was 10.

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS (광조사 방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kwon, Oh-Jin;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.102-109
    • /
    • 2003
  • The purpose of this study was to evaluate the linear polymerization shrinkage(%) and microhardness of composite resin(Z-100, 3M, USA) according to 2-step light curing method. Conventional light curing unit(Curing Light 2500, 3M USA) and 2-step light curing unit(Elipar Highlight, ESPE, Germany) were used as light source. The strain gauge method was used for determination of polymerization shrinkage(%). Samples were divided by 3 groups according to light curing methods (Group I : $450mW/cm^2$, 40sec, Group II : $650mW/cm^2$, 40sec, Group III : $150mW/cm^2$, 10sec & $650mW/cm^2$, 30sec). Preparations of acrylic molds were followed by filling and curing. Strain gauges attached to each sample were connected to a strainmeter. Measurements were recorded at each second for the total of 10 minutes including the periods of light application. And microhardness of each group after 24hours from light irradiation were measured. Obtained data were analyzed statistically using Ore-way ANOVA and/or Scheffe test. The results of the present study can be summarized as follows: 1. Composite resin in acrylic molds showed the initial expansion at the early phase of polymerization. This was followed by the contraction with the rapid increase in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The lowest linear polymerization shrinkage(%) was found in group III followed by group I, II during the measuring periods. 3. Group III using 2-step curing method showed statistically significant reduction of linear polymerization shrinkage(%) compared with group I, II at 1 minute and 10 minutes from light irradiation(p<0.05). 4. The microhardness values of each group not revealed significant difference.

  • PDF