Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy |
Kim, Ki-Won
(Department of Radiology, Kyung Hee University Hospital at Gang-dong)
Choi, Kwan-Woo (Department of Radiology, Asan Medical Center) Jeong, Hoi-Woun (Department of Radiological Technology, Baekseok Culture University) Jang, Seo-Goo (Department of Medical Science, Soonchunhyang University) Kwon, Kyung-Tae (Department of Radiological Technology, Dongnam Health University) Son, Soon-Yong (Department of Radiological Technology, Wonkwang Health Science University) Son, Jin-Hyun (Department of Radiological Technology, Shingu University) Min, Jung-Whan (Department of Radiological Technology, Shingu University) |
1 | Hoi-Woun Jeong, Jung-Whan Min, Jung-Min Kim et al: Performance characteristic of a Cs I (TI) Flat panel detector radiography system. Journal of Radiological Science and Technology, 35(2), 109-117, 2012 |
2 | Jung-Min Kim, Jung-Whan Min, Hoi-Woun Jeong et al: Correction Method of slit Modulation Transfer function on Digital Medical Imaging System. Journal of Radiological Science and Technology, 29(3), 133-139, 2006 |
3 | Soon-Yong Son, Hoi-Woun Jeong, Jung Whan Min et al: Comparison of noise power spectrum methodologies in measurements by using Various Electronic Portal Imaging Devices in Radiation Therapy. Journal of Radiological Science and Technology, 39(1), 97-104, 2016 |
4 | Soon-Yong Son, Hoi-Woun Jeong, Jung Whan Min et al: Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy. Journal of Radiological Science and Technology, 38(4), 451-461, 2015 DOI |
5 | Soon-Yong Son, Hoi-Woun Jeong, Jung Whan Min et al: Measurement of Image Quality According to the Time of Computed Radiography System. Journal of Radiological Science and Technology, 38(4), 365-374, 2015 DOI |
6 | Gopal A, Samant SS. Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics. Med Phys 36, 2006-2015 2009 DOI |
7 | Sawant A, Antonuk LE, El-Mohri Y. Slit Design for Efficient and Accurate MTF Measurement at Megavoltage X-ray Energies. Med Phys 34, 1535-1545, 2007 DOI |
8 | Dobbins III JT, Samei E, Ranger NT, et al: Intercomparis on of methods for image quality characterization. II. Noise power spectrum. Med Phys 33, 1466-1475, 2006 DOI |
9 | Seibert JA, Bogucki TM, Ciona T, Huda W, Karellas A, Mercier JR, et al. Report of AAPM Task Group 10, 1, 2006 |
10 | IEC (International Electrotechnical Commission), IEC 62220-1 (2003) |
11 | Cho HM, Kim HJ, Lee CL, et al: Imaging characteristics of the direct and mobile indirect digital radiographic systems. Proc IEEE M19-199, 3840-3846, 2007 |