• Title/Summary/Keyword: Measuring head

Search Result 413, Processing Time 0.025 seconds

The Monitoring on Gradual Change of Seepage Blocking State with the Hydraulic Head Loss Rate Change According to Passage of time in Sea Dike Embankment (수두손실률의 경시변화에 의한 방조제 제체의 점진적인 차수상태 변화 감시)

  • Eam, Sung Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • In this study it was adopted on sea dike monitoring that the safety monitoring with statistical limits which was adapted usually on safety monitoring by measuring pressures, stresses or deformations. And also the hydraulic head loss rate change according to passage of time was calculated for the purpose of safety monitoring. Safety monitoring by setting the statistical limit on the measured pore water pressure graphs need to be supplemented with an additional method of monitoring because the difference between the rise and fall of the tide was irregular. Safety monitoring by the limits set from values predicted by linear regression and standard errors on the hydraulic head loss graph was not affected by irregularity of tide. But if the condition of an embankment is changed gradually and slowly, it will not be detected on the hydraulic head loss graph. The graph of hydraulic head loss rate for every 24 hours vs date showed clearly that the sea water blocking state was getting better or not even though it was changed gradually and slowly.

Comparison of Characteristics of Texture and Groove Precision Lapping Plate by Measuring Frictional Forces (마찰력 측정을 이용한 홈(Groove) 및 임의패턴 초정밀 연마판의 특성 비교)

  • Loh, Byoung-Gook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.21-26
    • /
    • 2006
  • Characteristics of texture and groove precision lapping plate are experimentally investigated by Measuring frictional forces. It is found that the frictional coefficient decreases as the embedding of diamond particles progresses. The groove precision lapping plate with concentric micro-channels indicates superior capability in embedding micrometer-sized diamond particles and uniformity in diamond embedding compared with the texture precision lapping plate with a series of circular micro-channels.

  • PDF

The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient (측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

Result and Analysis of Performance Test of Pantograph for High Speed Train (고속전철 집전장치의 성능 계측 결과 및 분석)

  • Seo Sung-Il;Park Choon-Soo;Cho Yong-Hyun;Mok Jin-Yong;Kang Bu-Byung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.574-579
    • /
    • 2003
  • In this study, a measuring system for performance of pantograph was developed. The measuring system was installed on the prototype high speed train and measurement has been conducted during running on the test track. The measuring system is composed of video monitoring system and telemetry & data processing system. It can monitor the hazard behavior of pantograph and measure acceleration and vertical force of the pan head. Owing to the measuring system, performance of pantograph and safety of interface system of pantograph and catenary is evaluated.

  • PDF

Auditory-Perceptual and Acoustic Evaluation in Measuring Dysphonia Severity of Vocal Cord Paralysis (성대마비의 음성장애 측정을 위한 청지각적 및 음향학적 평가)

  • Kim, Geun-Hyo;Lee, Yeon-Woo;Park, Hee-June;Bae, In-Ho;Lee, Byung-Joo;Kwon, Soon-Bok
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.28 no.2
    • /
    • pp.106-111
    • /
    • 2017
  • Background and Objectives : The purpose of this study was to investigate the criterion-related concurrent validity of two standardized auditory-perceptual assessments and the Acoustic Voice Quality Index (AVQI) for measuring dysphonia severity in patients with vocal cord paralysis (VCP). Materials and Methods : Total 210 patients with VCP and 236 normal voice subjects were asked to sustain the vowel [a:] and to read aloud the Korean text "Walk". A 2 second mid-vowel portion of the sustained vowel and two sentences (with 26 syllables) were recorded. And then voice samples were edited, concatenated, and analyzed according to Praat script. Two standardized auditory-perceptual assessment (GRBAS and CAPE-V) were performed by three raters. Results : The VCP group showed higher AVQI, Grade (G) and Overall Severity (OS) values than normal voice group. And the correlation among AVQI, G, and OS ranged from 0.904 to 0.926. In ROC curve analysis, cutoff values of AVQI, G, and OS were <3.79, <0.00, and <30.00, respectively, and the AUC of each analysis was over .89. Conclusion : AVQI and auditory evaluation can improve the early screening ability of VCP voice and help to establish effective diagnosis and treatment plan for VCP-related dysphonia.

  • PDF

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

An Experimental Study on Hydraulic Characteristics Around Cutter-Head for Dredging (준설용 커터헤드 주변의 수리특성에 관한 실험적 연구)

  • Park, Jae Hyeon;Kim, Young Do;Chae, Dong Seok;Lee, Man Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.491-497
    • /
    • 2011
  • In this study, the flow characteristics around the cutter head, which makes the dredging soil suspended, were measured to evaluate the environmental affect of the dredging works. The PIV was used for measuring the flow characteristics around the cutter head for suction and non-suction cases. As the results, the mean velocity was decreased from the cutter head to outward. The mean velocity decreasing rate of the non-suction case was larger than that of the suction case, but the turbulence intensity decreasing rate of the non-suction case was smaller than that of the suction case because of the suction energy which makes the z-direction flow.

Development f head-neck complex dummy for experimental study (실험적 해석을 위한 머리-목 형태의 더미 개발)

  • Kim, Yeong-Eun;Nam, Dae-Hun;Koh, Chang-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1058-1072
    • /
    • 1997
  • A head-neck complex dummy, for measuring brain pressure and reaction force in the cervical spine was developed for experimental study related in injury mechanism. Dummy comprised aluminium-casted head with water filled cavity for simulating brain and mechanical neck assembled with six motion segments. Several kinds of experiments (compression, bending, cyclic modulus, relaxation and constant velocity profile) for the developed mechanical neck showed that this neck model is biomechanically reliable compared with in-vitro test results. As an application of developed head-neck complex dummy, shock absorbing properties of protective helmet was chosen. The experiments showed that the maximum pressure increment of brain after impact was tolerable compared with the guide line for mild brain injury pressure (25psi). Constrast to this results, the reaction force in the neck was high enough to produce failure in the cervical spine.

A Study on the Hydraulic Characteristics around the Cutter-Head along the Dredging (준설시 커터헤드 주변의 수리특성에 관한 연구)

  • Chae, Dong-Seok;Park, Jae-Hyeon;Kim, Young-Do;Lee, Man-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.588-592
    • /
    • 2008
  • In this study the flow characteristics around the cutter head which makes the dredging soil suspended were measured to evaluate the environmental affect of the dredging action. The PIV was used for measuring the flow characteristics around the cutter head for suction and non-suction cases. As the results, the mean velocity was decreased from the cutter head to outward. The mean velocity decreasing rate of the non-suction case was larger than that of the suction case, but the turbulence intensity decreasing rate of the non-suction case was smaller than that of the suction case because of the suction energy which makes the z-direction flow.

  • PDF