• Title/Summary/Keyword: Measuring head

Search Result 413, Processing Time 0.024 seconds

Evaluation of Tracheal Deviation in Patients with Thyroid Cancer (갑상선 암 환장서 기관지 편이 정도를 평가하는 방법의 연구)

  • Yoo, Young-Sam
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.138-144
    • /
    • 2010
  • Background: Tracheal deviations are encountered frequently in head and neck tumors especially in thyroid cancer. Dyspnea and stridor are symptom calling for surgery. The method of evaluation in tracheal deviation is not well established yet. This paper is aimed to suggest objective tools to evaluate tracheal deviation in relation to cervical vertebra. Material and Method: Ten cases of thyroid cancers were recruited retrospectively. Tracheal inner shadow and shape of cervical vertebra were reconstructed three dimensionally using 3D-doctor to compare position of trachea in relation to vertebral body. Extent of deviation was scored in relation to both lateral borders of vertebral body. Angles between trachea and spinous process were measured in axial CT and compared between study group and control group. Results: Deviation scores were statistically significant between study group (mean=1.1) and control group (mean=0) (p=0.0008). Deviation angles at maximal tumor size in study group (mean=160.3 Degrees) and deviation angles of control group (mean=177.1 Degrees) were statistically significant (p=0.0007). Angles at maximal deviation of three dimensional images ages in study group (mean=162.6 Degrees) and deviation angles of control group (mean=177.1 Degrees) were statistically significant (p=0.0089). Conclusion: Tracheal deviation can be evaluated using scoring of three dimensional images and measuring angle between trachea and vertebral spine.

  • PDF

Effects of Smooth and Textured Disks on Particle Generation in a Hard Disk Drive (하드 디스크 드라이브에서 Smooth 디스크와 LZT 디스크가 입자 발생에 미치는 영향)

  • Lee, Dae-Young;Huh, Sun-Young;Kang, Pil-Sun;Hwang, Jung-Ho;Cho, Keung-Youn;Kang, Tae-Sik
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.123-129
    • /
    • 2006
  • The head to disk spacing must be decreased to increase recording densities in hard disk drives. Recently, to decrease the head to disk spacing, smooth disk having no bumps onto the lading zone has used. In this research, we compared the number of particles generated ill HDD with smooth and textured disks. We used a sampling method using a particle sampler and a CPC (condensation particle counter) to detect particles in HDD. First, we sampled and counted particles generated with disk rotational speed and various rest times when the smooth disk and textured disks were used, then analyzed the sampled particles by SEM (scanning electron microscopy) and AES (auger electron spectroscopy). In results of measuring particles, more particles in case of LZT disk drive generated than that of the smooth disk drive in all test modes. The number of particles generated in the smooth disk was very low. The particle generation increased as the rest time increased (smooth/LZT disks) and more particles in case of LZT disk drive generated than that of the smooth disk drive. In results of analyzing particle components, Al, Ti, Si components were detected and we could not found differences between components in case of smooth/LZT disk drive.

  • PDF

Neck Pain and Functioning in Daily Activities Associated with Smartphone Usage

  • Lee, Hae-jung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.183-188
    • /
    • 2016
  • Purpose: The aim of the study was to investigate neck posture, range of motion, muscle endurance and self-report of pain and disability in smartphone users. Methods: Seventy-eight university student volunteers, aged between 18 and 30 years (mean age 23.2), were assessed for: a head-neck posture by measuring cranial vertical angle, neck range of motions using cervical range of motion device, and a deep neck flexor endurance using a stabilizer. Finally, subjects were asked about their neck pain and completed disability questionnaires, ie, Short Form McGill Pain Questionnaire, Neck Disability Index, and World Health Organization Disability Assessment Schedule 2.0. Results: Thirty-eight subjects experienced recurrent neck pain with/without upper limb pain (neck pain group) and 40 reported no current neck pain with/without upper limb pain (no neck pain group). Differences were found between groups on pain and disability questionnaires. Subjects with neck pain had significantly higher disability scores than those of no neck pain group. However, there were no differences observed between groups in a head-neck posture, neck range of motions, and deep neck muscle endurance time. The smartphone usage time was negatively correlated with neck pain intensity and disability score whereas it had positive relationship with flexibility and posture. Conclusion: Group differences were observed as lower capacity not only for neck specific daily activities but for general functioning in daily routine when the neck pain and no neck pain groups were compared. Therefore, functioning in daily activities should be investigated as prevention for further developing neck pain in smartphone users.

Neck Pain in Adults with Forward Head Posture: Effects of Craniovertebral Angle and Cervical Range of Motion

  • Kim, Dae-Hyun;Kim, Chang-Ju;Son, Sung-Min
    • Osong Public Health and Research Perspectives
    • /
    • v.9 no.6
    • /
    • pp.309-313
    • /
    • 2018
  • Objectives: The purpose of this study was to determine whether the cranial vertebral angle (CVA) and the range of motion (ROM) was different between participants with a forward head posture (FHP), with or without pain. Methods: Forty-four participants who had FHP participated in this study. The FHP was assessed digitally by measuring a lateral view the CVA for each subject. A cervical ROM device measured the cervical ROM. The volunteers were allocated to either, with pain (n = 22), or without pain (n = 22) groups, and pain was evaluated using the Numeric Pain Rating Scale. Results: The FHP in the pain group showed a significant difference in the CVA, and the cervical ROM in both flexion and extension, compared with those in the FHP without pain group (p < 0.05). Logistic regression analysis indicated that the occurrence of cervical area pain was higher amongst subjects who had a decreased CVA and flexion motion. Conclusion: This study suggested that decreased CVA and cervical flexion range, were predictive factors for the occurrence of pain in the cervical region.

Polishing Characteristics and Development of Automatic Die Polishing Machine by Liquid Honing (액체호닝에 의한 금형 자동 사상기계개발 및 가공 특성)

  • 김재도;류기덕;홍정석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.162-168
    • /
    • 2000
  • The automatic die polishing machine by liquid honing has been developed and experimented on the surface of machined die. The goal of development in the automatic die polishing machine by liquid honing is to increase the accuracy and the productivity in die polishing. To reach this goal, the polishing machine consists of the automatic measuring device for contour of die, the nozzle and pumping system to spray the powder mixed with liquid, and the 3-axis guides. Before polishing, the measuring device with a semiconductor laser scans the surface of mould to get the data of contour. The data store a PC and use to control the nozzle head to move above a couple of centimeters on the machined surface of die. The experimental parameters are the spraying time, the pressure, the size of abrasive grain and the mixing ratio between abrasive grain and liquid. The surface roughness is measured on the polished die which are SKDl 1 and Al7075 machined by NC. The surface roughness indicates the values of Rmax 0.5${\mu}{\textrm}{m}$ for Al7075 and Rmax 1.4${\mu}{\textrm}{m}$ for SKDl 1. It reduces the polishing time significantly and reduces the monotonous work for labors. As the results, the liquid honing system is useful method to apply for the die polishing and the automatic die polishing machine using liquid honing shows that it's very effective processing ability.

  • PDF

Evaluation of Design Parameters for Axial Bearing Capacity of Drilled Shafts by Bi-directional Loading Tests (양방향말뚝 재하시험을 통한 현장타설말뚝의 연직지지력 설계정수 산정)

  • Jung, Gyung-Ja;Cho, Chong-Suck;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.574-584
    • /
    • 2006
  • Bi-directional loading test data are available to evaluate the design parameters which reflect the characteristics of a construction method and the variations of ground at the site where drilled shafts are installed. The method to obtain the design parameters of a real bridge by hi-directional loading test was introduced. The plans of multi-level testing and installation of measuring instruments should be made according to the rough estimation of axial bearing capacity, the length of pile, and the construction method. While the relationship between end bearing resistance and displacement was obtained directly from the hi-directional loading test, the relationship between unit side resistance and displacement was calculated through the measuring values. 1% displacement of pile diameter was adopted as the criteria of failure for ultimate resistance. As the settlement of pile head at the total ultimate bearing capacity obtained from these method was less than 1.5 % of pile diameter, this method was conservative to use in the field.

  • PDF

A Study on the Body Shape of Chinese Adult Women - Focusing on Resident in Beijing and Sanghai - (중국(中國) 성인여성(成人女性)의 체형(體型) 연구(硏究) 제1보(第1報) - 북경(北京).상해지역(上海地域) 거주자(居住者)를 중심(中心)으로 -)

  • Sohn, Hee-Soon;Wee, Hye-Jung;Kim, Eun-Hee;Kang, Yeon-Kyung
    • Journal of Fashion Business
    • /
    • v.9 no.1
    • /
    • pp.137-151
    • /
    • 2005
  • The purpose of this study is to analyze body types of Chinese women and provide concrete information of body compatibility improvement of Chinese adult female clothing product to domestic ready-made clothes companies. As for the method of this study, statistical analysis is made of 111 items. This is done from June 23 to August 07, 2004. 1381 female subjects from age 19 to 50 participated in this study. They all live in Beijing and Shanghai in China. Data was analyzed by used SPSS/WIN10.0 Program. The results of this study are as follows. The important city(Beijing and Shanghai) the significant difference which body measuring hits especially appeared. The area dwelling woman in Shanghai appeared the height region and head region relation item a lot. The area dwelling woman in Beijing measuring appeared a lot from wide thick circumference length angle item. The upper half of body horizontal and vertical length compared to route with the obesity somatotype person it was investigated with the thing.

Flatness Control System of the Hot Strip by Using Tension Profile between Stands (스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템)

  • 홍완기;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

A Study on the Measurement of Contact Force of Pantograph of Korean High Speed Train (한국형 고속전철 집전장치 접촉력 계측에 관한 연구)

  • Seo, Sung-Il;Cho, Yong-Hyun;Park, Choon-Soo;Mok, Jin-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1453-1457
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, a system to measure the contact force of pantograph is developed and installed on the prototype high speed train, Contact force prevents the pantograph from separating from the catenary. However, excessive contact force causes rapid erosion of catenary. The contact force can be divided into lift force and spring force. Contact force measurement is conducted while the train runs on the test track. The lift force is measured by the load cell on the roof separately and combined with the spring force of pan-head to form the contact force. Measured results show that the contact force of the pantograph of Korean High Speed Train is below the upper limit regulated by the high speed train standards. The contact force measuring system provides data to evaluate safety of the catenary system.

  • PDF