• Title/Summary/Keyword: Measuring control standard

Search Result 199, Processing Time 0.029 seconds

A Case Study on Developing a Checking System of Gear Parts (기어 부품의 검사시스템 개발에 관한 사례)

  • Yun, Tae-Hong;Byun, Jai-Hyun
    • IE interfaces
    • /
    • v.21 no.4
    • /
    • pp.378-384
    • /
    • 2008
  • Small sized companies have not been successful in systematically applying statistical process control because of insufficient human resources. In this paper we present a case study of automatic checking system for a small sized company which produces various types of gears. A systematic way of automatically measuring gears is proposed and statistical analysis methods are presented. To reduce variation in the measurement data, a standard operating procedure is also proposed. This case study can be helpful to quality assurance practitioners of small sized companies who are willing to develop checking or inspection systems for their products.

Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer (초음파 변환기의 감도 교정 시스템 구성)

  • 사공성대;조문재;최봉열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF

A Study on the Calibration Technique of an Electrical Temperature Calibrator (전기식 온도 교정기 교정기법 연구)

  • Oh, Kwang-Suk;Lee, Wang-Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.944-951
    • /
    • 2016
  • Resistance temperature detectors (RTDs) and thermocouple sensors are broadly used to measure temperatures in the engineering and research fields. The contents of this standard calibration procedure (SCP) describe procedures related to the calculation of an electrical temperature calibrator and show different ways to indicate the calibration results, such as measurement uncertainty. As an SCP for the electrical temperature calibrator has not been developed yet, we studied the SCP and found a solution to this problem. In this paper, we present a mathematical model of the data and measurement variations with the calibration data results.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

A Study on the Evaluation Methodology for Information Security Level based on Test Scenarios (TS 기반의 정보보호수준 평가 방법론 개발에 관한 연구)

  • Sung, Kyung;Kim, Seok-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.4
    • /
    • pp.737-744
    • /
    • 2007
  • It need estimation model who is efficient and estimate correctly organization's information security level to achieve effectively organization's information security target. Also, estimate class information security level for this and need reformable estimation indicator or standard and estimation methodology of information security systems that application is possible should be studied in our country. Therefore many research centers including ISO are preparing the measuring and evaluating method for network duality. This study will represent an evaluating model for network security based on checklist. In addition, we propose ah measuring and evaluating method for network performance. The purpose of two studies is to present the evaluating procedure and method for measuring security of network on set workwill be identified and a measuring method and procedure will be proposed.

Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen (집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발)

  • Kim, Donhue
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.557-563
    • /
    • 2022
  • In order to measure the allergen penetration of micropore fabrics, it is necessary to develop a convenient and appropriate experimental method for measuring a pore size of micropore fabrics. In this study, a simple and economical experimental apparatus was developed for the analysis of the pore size of micropore fabrics by measuring the weight reduction rate. In addition, the allergen blocking properties was evaluated by measuring the pore sizes of various fabrics. According to this study, the size of the pores of the microporous fabric could be obtained by measuring the weight reduction rates. In addition, higher weight reduction rate was obtained as the suction pressure passing through the particle permeation device decreased and the suction time was increased. It is expected that the developed experimental method and apparatus can be utilized as an experimental standard for quality control methods to verify the effectiveness of micropore fabrics used for house dust mite blocking bedding.

Networked Control System Design Accounting for Time-Delays with Application to Inverted Pendulum

  • Park, Byung-In;Yoo, Ho-Jun;Kwon, Oh-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1470-1473
    • /
    • 2003
  • In this paper the networked control systems (NCS) problem is discussed where plants and controllers are distributed and interconnected by a common network. NCS is designed with LQ regulator and applied to an inverted pendulum accounting for the multiple time delays. We are to deals with a networked control system with a single controller, multiple sensors and multiple actuators. Since these parts are distributed, they are interconnected by communication networks. An NCS with LQ regulator is designed and applied to an inverted pendulum as a benchmark plant to check its performance under time delays induced by the network. Network induced delays are composed of two parts. One is the delay from controller to plant, and another is from plant to controller. They are assumed to be constant in this paper, and the plant and controller are discretized. To apply the LQ regulator the NCS model is transformed to a standard model with delayed states as state variable. And real network induced delay is measuring in TCP/IP network assuming that two delays are constant.

  • PDF

Effects of Earplug Wear on Patients' Displeasure and Anxiety Caused by Operation-Induced Noises (귀마개 적용이 수술 소음으로 인한 불쾌감 및 불안에 미치는 효과)

  • Kim, Sang Rip;Kim, Yeong Kyeong
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.3
    • /
    • pp.319-328
    • /
    • 2011
  • Purpose: This study was done to identify nursing interventions clinically applicable to relieve displeasure and anxiety of patients having an operation in which loud noise was unavoidable. Methods: Participants were 34 patients scheduled to have a total knee replacement. They were assigned to either the control (17 patients) or experimental (17 patients) group. Data were collected from September to November 2010. The instruments used for the survey included noise-control earplugs, a noise level meter (TES-1358) and a structured scale measuring degree of noise perception, displeasure and anxiety. Data were analyzed using frequency, percentage, standard deviation, $x^2$-test, and t-test with the SPSS WIN 18.0 program. Results: Hypothesis 1: 'The displeasure levels of the experimental group of patients wearing earplugs will be lower than the control group patients without earplugs' was accepted (t=-20.769, p<.001). Hypothesis 2: 'The anxiety levels of the experimental group of patients wearing earplugs will be lower than the control group patients without earplugs' was accepted (t=-6.298, p<.001). Conclusion: Based on these findings, the wearing of earplugs for patients having a surgical operation with loud noises is recommended as an effective nursing intervention to relieve patient displeasure and anxiety during their surgical operations.

A Study on Algorithm for Gear Profile Measurement Using a Standard Gear (표준기어를 이용한 기어 프로파일 정밀측정 알고리즘에 관한 연구)

  • Lee, Min-Ki;Lee, Eung-Suk;Kim, Kuang-Jung;Park, Hyun-Yoong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.555-561
    • /
    • 2012
  • In this paper, a method to control the noise and vibration of a standard gear transmitting mechanical power in the transmission insides, to things regarding a way to inspect the gear which was processed minutely. In an algorithm used to accurately measure a work gear, the measurements of the master gear are considered as the basis. The existing method considers one rotation of the standard gear and monitor gear, and that carried out mastering work in frequency ways. In this study, an algorithm to measure standard gear and monitor gear is proposed along with methods to calculate an error of the monitor gear and to significantly increase the precision of gear measurement. Further, the algorithm is fast and is expected to be capable of accurately measuring for mastering processing.