• Title/Summary/Keyword: Measuring Principle

Search Result 290, Processing Time 0.041 seconds

Effect of the Current Probe Position on Ground Resistance Measurement Using Fall-of-Potential Method (전위강하법에 의한 접지저항 측정에 미치는 전류보조전극의 위치의 영향)

  • Lee, B.H.;Eom, J.H.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1874-1876
    • /
    • 2000
  • In this paper, the effects of the positions of the current probe on the measurements of the ground resistanc, and potential gradients with fall-of-potential method are described, and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of the measuring auxiliary probes. The ground resistance is calculated by applying the 61.8% lute using fall-of-potential method.

  • PDF

Analysis for Ground Impedance Measurement Influenced by Distance of Current Probe and Frequency (접지임피던스 측정에 관한 전류보조전극 거리 및 주파수의 영향 분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.289-292
    • /
    • 2009
  • This paper describes the analysis for ground impedance measurement influenced by distance of current probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 5[m] to 20[m] and the measuring frequency was ranged in 55[Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of current probe when the ground impedance was measured at grounding system.

  • PDF

GMI Magnetic Field Sensor Based on a Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.221-224
    • /
    • 2010
  • A laboratory sensor model was designed, constructed, and tested based on a newly proposed working principle of magnetic field detection. The principle of sensing employed a time-coded method in correlation with exploiting the advantageous features of the GMI effect. The sensor demonstrated a sensitivity of $10\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. The sensing element in the form of an amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity of the GMI sensor to better than 0.2% in the measuring range of ${\pm}100\;{\mu}T$.

Measurement of Vibration Intensity of a Semi-Infinite Beam Using the Principle of Reciprocity (가역성 원리를 이용한 반무한보의 진동 인텐시티 측정)

  • 양귀봉;길현권;홍석윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1073-1077
    • /
    • 2001
  • The objective of this paper is to apply an experimental method based on the principle of reciprocity to measuring the structural intensity. Since only one accelerometer is used in this method it has the advantages of shortening measurement time. reducing accelerometer phase error. overcoming the limitation that the situation should be stationary during the experiment. It has been used to measure the vibration intensity of an infinite beam (beam with damped ends) and a semi-infinite beam (beam with simply supported and damped ends). Results showed that the experiment method based on the principle of reciprocity can be effectively used to measure the structural intensity.

  • PDF

Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class (수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발)

  • Choi, Jun-Seop;Lee, Sung-Gu
    • 대한공업교육학회지
    • /
    • v.32 no.1
    • /
    • pp.117-133
    • /
    • 2007
  • The purpose of this study was to develop the force measuring device of learning wind tunnel, teaching-learning materials in order to enhance understanding of flight principle and give interest about aviation technology in secondary school. The content of this study was consisted of the development and experiment of force measuring device for learning wind tunnel. The main results of this study were as follows: This device developed here is simple structure applying lever principle instead of the comparatively expensive load cell used in engineering college or a aviation research institute and so on. Measurement of lift and drag as well as the comparison experiment of a fluid resistance is possible with only one device developed here. The lift coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And the stall phenomenon was found under the larger angle of attack of experimental rather than expected theoretical values. The drag coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And drag coefficient the rate of increasement of the experimental values increased more gently than its theoretical values.

Structural damage detection by principle component analysis of long-gauge dynamic strains

  • Xia, Q.;Tian, Y.D.;Zhu, X.W.;Xu, D.W.;Zhang, J.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.2
    • /
    • pp.379-392
    • /
    • 2015
  • A number of acceleration-based damage detection methods have been developed but they have not been widely applied in engineering practices because the acceleration response is insensitive to minor damage of civil structures. In this article, a damage detection approach using the long-gauge strain sensing technology and the principle component analysis technology is proposed. The Long gauge FBG sensor has its special merit for damage detection by measuring the averaged strain over a long-gauge length, and it can be connected each other to make a distributed sensor network for monitoring the large-scale civil infrastructure. A new damage index is defined by performing the principle component analyses of the long-gauge strains measured from the intact and damaged structures respectively. Advantages of the long gauge sensing and the principle component analysis technologies guarantee the effectiveness for structural damage localization. Examples of a simple supported beam and a steel stringer bridge have been investigated to illustrate the successful applications of the proposed method for structural damage detection.

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

Fabrication of Static Fiber Optic Gyrocompass (정적방식 광섬유 자이로콤파스의 제작)

  • 이석정;홍창희
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 1997
  • This paper describe the method and the result of making a fiber optic gyrocompass measuring the heading angles of a ship with a fiber optic sensor. As the method seeking for the heading angles, it is possible to get the heading angles by measuring the output signals from a stationary fiber optic sensor in at least three directions such as a heading direction and other two directions having phase difference ${\phi}1$ and ${\phi}2$ to the heading. We made the static fiber optic gyrocompass by a high performance fiber optic sensor having scale factor of 210mV/deg/s and resolution of 0.5deg/hr using this principle. The accuracy of this system was $0.29^{\circ}$ from 20 numbers of data measuring the arbitrary heading angle.

  • PDF

Design of a High Stable Measuring Circuit for Radioactive Pulses (방사선 펄스의 고안정 계측회로 설계)

  • 송재용;한주섭;천상규;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF

Measuring Thermal Conductivity of Nanofluids and Heat Transfer Enhancement (나노유체의 열전도율 측정과 열전달 향상)

  • Lee, Shin-Pyo;Choi, Cheol;Oh, Je-Myung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.147-150
    • /
    • 2006
  • A new class of heat transfer fluid with higher thermal conductivity, called nanofluids has been developed by Dr. S. Choi about decade ago. Many exciting experimental and theoretical results have been reported worldwide to predict the thermal conductivity enhancement of nanofluids, however, they sometimes show excessive large discrepancies between each other. This kind of disagreements in thermal conductivity data is partly ascribable to the accuracy of the measuring apparatus, that is, mostly used THM(transient hot-wire method). New thermal conductivity measuring method whose principle is different from that of conventional THM is proposed in this article and measurements and uncertainty analysis were made for the three nanofluid samples with different particle concentration of pure, 2% and 4% of AlN nanofluids.

  • PDF