• 제목/요약/키워드: Measuring Principle

검색결과 293건 처리시간 0.029초

열전형변환기를 사용한 정밀 교류직류전력측정장치 개발 (Development of the precision AC/DC power measuring system on the basis of thermal converters)

  • 박영태;장석명
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.9-13
    • /
    • 1996
  • The high precision of electrical power and energy measurements with wide range of frequency and power factor can be achieved by using the thermo-electrical power comparators. The paper describes the development of a precision power measuring system by using a ac/dc power comparator for measurement of power. Based on a thermal principle, the instrument performs ac-dc transfer for ac power measurements in the range of currents from 0 to 5 $A_{ms}$ , voltages from 0 to 240 $V_{ms}$ , power factors from 0 to 1 and frequencies from 0 to 1000 Hz. Two thermal converters with two heater are used in the functional element of the comparators. The ac-dc transfer accuracy is better than 20 ppm at unity power factor and better than 50 ppm at 0.5 power factor. (author). 8 refs., 5 figs., 3 tabs.

  • PDF

3차원 좌표 측정기 구조 해석

  • 양종화;박준호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 추계학술대회 논문집
    • /
    • pp.220-225
    • /
    • 2001
  • High rigidity of structure is required to obtain its accuracy and performance in a coordinates measuring machine(CMM). Modeling of bridge column of a CMM is introduced and the unit-load method by the principle of virtual work is suggested to analyze deflections of bridge column which is designed for high rigidity. Also design of porous air bearings of each moving axis is introduced to satisfy the loading conditions.

Discontinuous Surface Profile measurement using Wavelength Scanning Interferometer(WSI)

  • Kang, Chul-Goo;Cho, Hyoung-Suck;Lee, Jae-Yong;Hahn, Jae-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.4-127
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. A number of visual or optical technologies have been successfully applied to measure three dimensional surfaces. Especially, the shape measurement using an interferometric principle becomes a successful methodology. However, those conventional interferometric methods to measure surface profile have an inherent shortcoming, namely 2∏ ambiguity problem. The problem inevitably happens when the object to be measured has discontinuous shape due to the repetition of interferometric signal with phase period of 2∏. Therefore, in this paper, we choose as a shape measuring method, ...

  • PDF

동작 특성 추출 : 동작 모방에 기초한 향상된 역 운동학 (Motion Characteristic Capturing : Example Guided Inverse Kinematics)

  • 탁세윤
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 1999년도 춘계학술대회 논문집
    • /
    • pp.147-151
    • /
    • 1999
  • This paper extends and enhances the existing inverse kinematics technique using the concept of motion characteristic capturing. Motion characteristic capturing is not about measuring motion by tracking body points. Instead, it starts from pre-measured motion data, extracts the motion characteristics, and applies them in animating other bodies. The resulting motion resembles the originally measured one in spite of arbitrary dimensional differences between the bodies. Motion characteristics capturing is a new principle in kinematic motion generalization to process measurements and generate realistic animation of human being or other living creatures.

  • PDF

마그네토스트릭션 효과를 이용한 비접촉 모달 테스팅 기법 (Noncontact Modal Testing Method Using Magnetostriction Effects)

  • 조승현;이호철;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.701-707
    • /
    • 2000
  • In this work, we propose to employ magnetostrictive sensors to develop a new non-contacting modal testing method. Specific applications are made in the modal testing of a beam in bending. The role of bias magnetic fields in measuring bending waves is addressed and an approximate analysis to explain the principle to measure bending signals is carried out. The measured modal data by the present method agree well with those by conventional methods using accelerometers.

  • PDF

Multi-sensor Visual inspection for Seamless Steel Pipe´s Straightness

  • Tomoo, Aoyama;Zhang, Y.G.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.88.3-88
    • /
    • 2001
  • In this paper, an on-line multi-sensor visual inspection technique for seamless steel pipe´s straightness is developed. The basic principle of the visual measuring method is detailed. The modeling of visual sensor, measurement system and data processing are presented. In order to test the accuracy of the multi-sensor visual inspection, an experiment inspecting the straightness of a 1500mm long seamless steel pipe is made. The experiment results show that the visual inspection technique can achieve on-line measurement and offers high precision and stability.

  • PDF

93 대전엑스포 꿈돌이 조각가로보트의 인물형상 측정시스템 (3-D Profile Measurement System of Live Human Faces for the '93 Taejon Expo Kumdori Robot Scupltor)

  • 김승우;박현구;김문상
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.670-679
    • /
    • 1995
  • This paper presents the 3-D profile measurement system of live human faces, which was developed specially for 'KUMDORI sculptor robot' of the '93 Taejon Exposition. '93 Taejon EXPO. The basic principle for measurement adopts the slit beam projection which is a method of measuring 3-D surface profiles using geometric optics between the slit beam and the CCD camera. Since the slit beam projection consumes long measuring time, it is unfit to measure the 3-D profiles of living objects as human. Therefore, the projection type slit beam method which consumes short measuring time is newly suggested. And an algorithm to reconstruct the 3-D profile from the deformed images using finite approximated calibration is suggested and practically implemented. The projection type slit beam method was applied to spectators in a period of '93 Taejon EXPO. The measurement results show that the technique is suitable for 3-D face profile measurement on a living body.

저주파 접지임피던스 측정에 미치는 보조전극의 영향 (Effects of Auxiliary Probe on Low Frequency Ground Impedance Measurement)

  • 길형준;김동우;김동욱;이기연;김향곤;문현욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.367-370
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the auxiliary probes on the measurements of the low frequency ground impedance with the fall-of-potential method are described iud the testing techniques to minimize the measuring errors are proposed. The fall-of-pot ential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the characteristics of ground impedance due to the location of the potential probe, ground impedances were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from 10[m] to 50[m]. Also, the potential robe was located at 30[$^{\circ}$], 40[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], and 180[$^{\circ}$]. The results could be help to determine the location of potential probe when the ground impedance was measured at grounding system.

  • PDF

PN-PEMS 장비의 개발 및 평가 (Development and Performance Evaluation of PN-PEMS)

  • 황인규;김민호;우승철;이기형;안강호
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.163-167
    • /
    • 2014
  • Particle number portable emission measurement system (PN-PEMS) is an instrument for measuring number concentration of automobile exhaust. The principle of some pre-existing commercial PN-PEMS is to charge particles and display the number of particles by measuring current. However, this method has some problems for measuring exhaust. In this study, to solve these issues, we have developed a single particle counting PN-PEMS based condensation particle counter (CPC). The PN-PEMS based CPC does not affect driving conditions and it is convenient for mobile because the instrument is small and light in structure. We evaluated counting efficiency of PN-PEMS based CPC by using electrostatic method (electrometer and Faraday cup).