Nano-Bio Sensor Technology using Micro Cantilever

미세 캔틸레버 방식에 의한 나노-바이오 센서 기술

  • 허신 (한국기계연구원 나노기계연구본부 바이오기계 연구팀) ;
  • 윤여흥 (신시너티대학교) ;
  • 이성철 (전북대학교 기계공학과)
  • Published : 2008.11.01

Abstract

Keywords

References

  1. Lavrik, N. V., Sepaniak, M. J. and Datskos, P. G., "Cantilever transducers as a platform for chemical and biological sensors," Rev. of Scientific Instruments, Vol. 75, No. 7, pp. 2229-2253, 2004 https://doi.org/10.1063/1.1763252
  2. Lang, H. P., Hegner, M. and Gerber, C., "Cantilever Array Sensors," Materials Today,Vol. 8, Issue 4, pp. 30-36, 2005
  3. Raiteri, R., Grattarola, M., Butt, H. -J. and Skladal, P., "Micro-Mechanical Cantilever-based Biosensors," Sensors and Actuators B: Chemical, Vol. 79, No. 2, pp. 115-126, 2001 https://doi.org/10.1016/S0925-4005(01)00856-5
  4. Meyer, G. and Amer, N. M., "Optical-Beam-Deflection Atomic Force Microscopy: The NaCl (001) surface," Appl. Phys. Lett., Vol. 56, Issue 21, pp. 2100-2101, 1990 https://doi.org/10.1063/1.102985
  5. Blanc, N., Brugger, J., Rooij, N. F. and Dürig, U., "Scanning Force Microscopy in the Dynamic Mode using Micro-fabricated Capacitive Sensors," J. Vac. Sci. Technol. B, Vol. 14, No. 2, pp. 901-905, 1996 https://doi.org/10.1116/1.589171
  6. Tortonese, M., Barrett, R. C. and Quate, C. F., "Atomic Resolution with an Atomic Force Microscope using Piezoresistive Detection," Appl. Phys. Lett., Vol. 62, Issue 8, pp. 834-836, 1993 https://doi.org/10.1063/1.108593
  7. Zurn, S., Hsieh, M., Smith, G., Markus, D., Zang, M., Hughes, G., Nam, Y., Arik, M. and Polla, D., "Fabrication and Structural Characterization of a Resonant Frequency PZT Micro-cantilever," Smart Mater. Struct., Vol. 10, No. 2, pp. 252-263, 2001 https://doi.org/10.1088/0964-1726/10/2/310
  8. Thundat, T., Wachter, E. A., Sharp, S. L. and Warmack, R. J., "Detection of Mercury Vapor using Resonating Micro-cantilevers," Appl. Phys. Lett., Vol. 66, Issue 13, pp. 1695-1697, 1995 https://doi.org/10.1063/1.113896
  9. Lang, H. P., Baller, M. K., Berger, R., Gimzewski, J. K., Battiston, F. M., Fornaro, P., Ramseyer, J. P., Meyer, E. and Güntherodt, H. J., "An Artificial Nose based on a Micro-mechanical Cantilever Array," Analytica chemica acta., Vol. 393, Issues 1-3, pp. 59-65, 1999 https://doi.org/10.1016/S0003-2670(99)00283-4
  10. Pinnaduwage, L. A., Wig, A., Hedden, D. L. and Gehl, A., "Detection of Trinitrotoluene via Deflagration on a Micro-cantilever," J. Appl. Phys., Vol. 95, Issue 10, pp. 5871-5875, 2004 https://doi.org/10.1063/1.1697619
  11. Ji, H. -F., Hansen, K. M., Hu, Z. and Thundat, T., "Detection of pH Variation using Modified Micro-cantilever Sensors," Sensors and Actuators B: Chemical, Vol. 72, Issue 3, pp. 233-238, 2001 https://doi.org/10.1016/S0925-4005(00)00678-X
  12. Ji, H. -F., Finot, E., Dabestani, R., Thundat, T., Brown, G. M. and Britt, P. F., "A Novel Self-Assembled Monolayer (SAM) coated Micro-cantilever for low level Cesium Detection," Chem. Commun., Vol. 6, pp. 457-458, 2000
  13. Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., Güntherodt, H. -J., Gerber, Ch. And Gimzewski, J. K., "Translating Bio-molecular Recognition into Nano-mechanics," Science, Vol. 288, No. 5464, pp. 316-318, 2000 https://doi.org/10.1126/science.288.5464.316
  14. Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J. and Majumdar, A., "Bioassay of Prostate-Specific Antigen (PSA) using Micro-cantilevers," Nat. Biotechnol., Vol. 19, No. 9, pp. 856-860, 2001 https://doi.org/10.1038/nbt0901-856
  15. Carrascosa, L. G., Moreno, M., Alvarez, M. and Lechunga, L. M., "Nano-mechanical Bio Sensors: a New Sensing Tool," TrAC Trends in analytical chemistry, Vol. 25, Issue 3, pp. 196-206, 2006 https://doi.org/10.1016/j.trac.2005.09.006
  16. Lechuga, L. M., Tamayo, J., Álvareza, M., Carrascosaa, L. G., Yuferaa, A., Doldána, R., Peralíasa, E., Ruedaa, A., Plazaa, J. A., Zinovieva, K., Domíngueza, C., Zaballosb, A., Morenob, M., Martínez-Ab, C., Wennc, D., Harrisc, N., Bringerd,C., Bringerd, V., Campsd, T., Vergnenègred, C., Fontained, C., Díaze, V. and Bernad, A., "A Highly Sensitive Micro-system based on Nano-mechanical Biosensors for Genomics Applications," Sensors and Actuators B: Chemical, Vol. 118, Issues 1-2, pp. 2-10, 2006 https://doi.org/10.1016/j.snb.2006.04.017
  17. http://nano.caltech.edu/Research/NEMS%20Nose/NEMS_Nose.htm
  18. Schwarzer, N. and Richter, F., "On the determination of film stress from substrate bending: Stoney's formula and its limits," TU Chemnitz, Fakultat fur Naturwissenschaften, pp. 1-17, 2004