• Title/Summary/Keyword: Measurements

Search Result 21,626, Processing Time 0.053 seconds

On the Nighttime Correction of CO2 Flux Measured by Eddy Covariance over Temperate Forests in Complex Terrain (복잡지형의 온대산림에서 에디 공분산으로 관측된 CO2 플럭스의 야간 자료 보정에 관하여)

  • Kang, Minseok;Kim, Joon;Kim, Hyun-Seok;Thakuri, Bindu Malla;Chun, Jung-Hwa
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.233-245
    • /
    • 2014
  • Nighttime correction of $CO_2$ flux is one of the most important and challenging tasks in eddy covariance measurements over a complex mountainous terrain. In this study, we have scrutinized the quality and the credibility of the $CO_2$ flux datasets which were produced by employing three different methods of nighttime correction, i.e., (1) friction velocity ($u^*$) correction, (2) light response curve (LRC) correction, and (3) advection-based van Gorsel (VG) correction. The whole year datasets used in our analysis were collected at the two KoFlux tower sites (i.e., GDK deciduous forest site at the upper hill and GCK coniferous forest site at the lower hill) located in the valley of Gwangneung National Arboretum in central Korea. The resultant magnitudes and patterns of ecosystem respiration ($R_E$), gross primary productivity (GPP), and net ecosystem exchange (NEE) of $CO_2$ showed marked differences among the datasets produced with three different correction methods, which were also site-specific. The examination from micrometeorological and ecological perspectives suggests that the major cause of some inconsistency seems to be associated with the advection of $CO_2$ along the sloping terrain and the inappropriate selection of the correction data that might have been already affected by advective flows. The comparison with the results from other studies indicated that the overall characteristics of the corrected $CO_2$ fluxes at GDK and GCK (except those with LRC correction) were well within the ranges reported in the literature for various ecosystems in East Asia in similar latitudes. However, our study also implies that there will be always a room for further improvement in the present datasets. Therefore, caution must be exercised for the data users in order to properly use the updated version of datasets through transparent, open and participatory communication with data producers.

Evaluation of the Satellite-based Air Temperature for All Sky Conditions Using the Automated Mountain Meteorology Station (AMOS) Records: Gangwon Province Case Study (산악기상관측정보를 이용한 위성정보 기반의 전천후 기온 자료의 평가 - 강원권역을 중심으로)

  • Jang, Keunchang;Won, Myoungsoo;Yoon, Sukhee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Surface air temperature ($T_{air}$) is a key variable for the meteorology and climatology, and is a fundamental factor of the terrestrial ecosystem functions. Satellite remote sensing from the Moderate Resolution Imaging Spectroradiometer (MODIS) provides an opportunity to monitor the $T_{air}$. However, the several problems such as frequent cloud cover and mountainous region can result in substantial retrieval error and signal loss in MODIS $T_{air}$. In this study, satellite-based $T_{air}$ was estimated under both clear and cloudy sky conditions in Gangwon Province using Aqua MODIS07 temperature profile product (MYD07_L2) and GCOM-W1 Advanced Microwave Scanning Radiometer 2 (AMSR2) brightness temperature ($T_b$) at 37 GHz frequency, and was compared with the measurements from the Automated Mountain Meteorology Stations (AMOS). The application of ambient temperature lapse rate was performed to improve the retrieval accuracy in mountainous region, which showed the improvement of estimation accuracy approximately 4% of RMSE. A simple pixel-wise regression method combining synergetic information from MYD07_L2 $T_{air}$ and AMSR2 $T_b$ was applied to estimate surface $T_{air}$ for all sky conditions. The $T_{air}$ retrievals showed favorable agreement in comparison with AMOS data (r=0.80, RMSE=7.9K), though the underestimation was appeared in winter season. Substantial $T_{air}$ retrievals were estimated 61.4% (n=2,657) for cloudy sky conditions. The results presented in this study indicate that the satellite remote sensing can produce the surface $T_{air}$ at the complex mountainous region for all sky conditions.

Seasonal and Inter-annual Variability of Water Use Efficiency of an Abies holophylla Plantation in Korea National Arboretum (국립수목원의 전나무(Abies holophylla) 조림지의 물 이용 효율의 계절 및 경년 변동)

  • Thakuri, Bindu Malla;Kang, Minseok;Zhang, Yonghui;Chun, Junghwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.366-377
    • /
    • 2016
  • Water use efficiency (WUE) is considered as an important ecological indicator which may provide information on the process-structure relationships associated with energy-matter-information flows in ecosystem. The WUE at ecosystem-level can be defined as the ratio of gross primary productivity (GPP) to evapotranspiration (ET). In this study, KoFlux's long-term (2007-2015) eddy covariance measurements of $CO_2$ and water vapor fluxes were used to examine the WUE of needle fir plantation in Korea National Arboretum. Our objective is to ascertain the seasonality and inter-annual variability in WUE of this needle fir plantation so that the results may be assimilated into the development of a holistic ecological indicator for resilience assessment. Our results show that the WUE of needle fir plantation is characterized by a concave seasonal pattern with a minimum ($1.8-3.3g\;C{\cdot}(kg\;H_2O)^{-1}$) in August and a maximum ($5.1-11.4g\;C{\cdot}(kg\;H_2O)^{-1}$) in February. During the growing season (April to October), WUE was on average $3.5{\pm}0.3g\;C\;(kg\;H_2O)^{-1}$. During the dormant seasons (November to March), WUE showed more variations with a mean of $7.4{\pm}1.0g\;C{\cdot}(kg\;H_2O)^{-1}$. These values are in the upper ranges of WUE reported in the literature for coniferous forests in temperate zone. Although the growing season was defined as the period from April to October, the actual length of the growing season (GSL) varied each year and its variation explained 62% of the inter-annual variability of the growing season WUE. This is the first study to quantify long-term changes in ecosystem-level WUE in Korea and the results can be used to test models, remote-sensing algorithms and resilience of forest ecosystem.

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

A Respiration Rate Measurement of Fresh Fruits and Vegetables with a Corrected Pressure Variation Method (수정된 압력변위법을 이용한 과채류 호흡속도 측정)

  • Lee, Hyun-Dong;Chung, Hun-Sik;Kang, Jun-Soo;Chung, Shin-Kyo;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.1119-1124
    • /
    • 1997
  • This study was carried out for improvement and correction of the traditional pressure variation method (PVM) in the respiration rate measurements of fresh fruits and vegetables using a microcomputer system and a differential pressure sensor. Water vapor pressure in the container was calculated by equations for psychrometric calculations. At the beginning of experimental period water vapor pressure in the container was increased and maintained constantly in the most experimental period, but was decreased dramatically after $CO_2$ scrubbing. The percentages of water vapor pressure on total differential pressure were $33{\sim}46%$ at $1^{\circ}C$, $23{\sim}45%$ at $11^{circ}C$ and $35{\sim}53%$ at $21^{\circ}C$. The differences between the respiration rates determined by gas chromatography and corrected pressure variation method (CPVM) were $0.2{\sim}0.3\;mgCO_2kg^{-1}h^{-1}$ at $1^{\circ}C$, $0.2{\sim}2.9\;mgCO_2kg^{-1}h^{-1}$ at $11^{\circ}C$ and 1.0{\sim}9.0\;mgCO_2kg^{-1}h^{-1}$ at $21^{circ}C$, while those between gas chromatography and normal pressure variation method (PVM) were $0.8{\sim}1.2\;mgCO_2kg^{-1}h^{-1}$ at $1^{\circ}C$, $3.9{\sim}11.0\;mgCO_2kg^{-1}h^{-1}$ at $11^{\circ}C$ and $8.0{\sim}32.0\;mgCO_2kg^{-1}h^{-1}$ at $21^{circ}C$, respectively. The differences of the respiration rates with CPVM were smaller than those with PVM. CPVM, therefore, were more exact and convenient method than PVM in the measurement of respiration rate of fresh produce.

  • PDF

An Experimental Study on Establishing Criteria of Gripping Work in Construction Site (건설 현장 악력 작업안전 기준 설정에 관한 실험적 연구)

  • 손기상;이인홍;최만진;안병준
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.81-95
    • /
    • 1995
  • Now, safety assurance in construction sites should be accomplished by its own organization rather than control of the code or government. It is believed that the safety assurance can be considerably improved by a lecture or an education using the existing theories or literatures up to now, but it is thought that fundamental safety assurance we not able to be accomplished without developing safety devices '||'&'||' equipment or taking fundamental measures, based on the result analyzed from workers behaviors. There are various behaviors of the workers showed in construction site, but only tests for hammerusing works such as form, re-bar, stone workers directly related to the grip strength are mainly performed, investigated and measured here for the study. The above works are similar to power grip, 7th picture on seven items which are categorized for hand grip types(Ammermin 1956 ; Jones ; Kobrick 1958). Measurements of grip strength are commonly taken in anthropometric surveys. They are easy to administer but unfortunately it is rather dubious whether they yield any data that are of interest to the engineer. Very fewer controls of tools are grasped and squeesed studies showed very little overall correlation between grip strength and other measures of bodily strength (Laubach, Kromer, and Thordsen 1972), but hammer-using work which is practically progressed in construction site are mainly influenced with grip strength. According to the investigation on work measurement, it is shown that 77% of form worker are using hammer to be related to grip strength. In this study, it is particularly noticed that wearing safety gloves in construction site is required for workers safety but 20% difference between grip strength with safety gloves and without ones are commonly neglected in the site(Fig. 1). Nevertheless, safety operation with consideration of the above 20% difference is not considered in the construction site. Factors of age, kinds of work, working time, with or without safety gloves are in vestigated '||'&'||' collected at the sites for this study. Test, not at each working hour but at 14 : 00 when the almost all of the workers think the most tired, resulting from the questionaires, also when it is shown on the research report has been performed and compared for main kinds of works : form '||'&'||' re-bar work. Tests were performed with both left SE rightand of the workers simultaneously in construction site using Rand Dynamometer(Model 78010, Lafayette Instrument Co., Indiana, U.S.A) by reading grip strength on the gauge while they are pulling, and then by interviewing on their ages, works, experiences and etc., directly. The above tests have been performed for the dates of 15th march-26th May '95 with consideration of site condition. And even if various factors of ambient temperature on the testing date, working condition, individual worker's habit and worker's condition of the previous ate are concerned with the study. Those are considered as constants in this study. Samples are formwork 53, rebar 62, electrician 5, plumber 4, welding 1 from D construction Co., Ltd, ; formwork 12, re-bar 5, electrician 2, from S construction Co., Ltd, , formwork 78, re-bar 18, plumber 31, electrician 13, labor 48, plumber 31, plasterer 15, concrete placer 6, water proof worker 3, maisony 5 from B construction Co., Ltd. As In the previously mentioned, main aspect to be investigated in this study will be from '||'&'||' re-bar work because grip strength will be directly applied to these two kinds of works ; form '||'&'||' re-bar work, eventhough there are total 405 samples taken. It is thought that a frequency of accident occurrence will be mainly two work postures "looking up '||'&'||' looking down" to be mainly sorted, but this factor is not clarified in this study because It will be needed a lot of work more. Tests has been done at possible large scale of horizontally work-extended sites within one hour in order to prevent or decrease errors '||'&'||' discrepancies from time lag of the test. Additionally, the statistical package computer program SPSS PC+has been used for the study.

  • PDF

Application Strategies of Eye-tracking Method in Nightscape Evaluation (야간경관 평가에서의 아이트래킹 분석 적용 연구)

  • Kang, Youngeun;Kim, Mintai
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.87-97
    • /
    • 2015
  • There's a trend towards vitalization of nightscape planning businesses nationally and locally as well for city image making and activation of regional economy, but there is still no systematic nightscape planning going on for lack of relevant researches and objective evaluations. This study aims to suggest the guideline for nightscape planning by conducting an eye tracking experiment and survey for recognizing the characteristics of a nightscape. Furthermore, the authors intended to verify the eye-tracking method as a tool for landscape evaluation. The research site was restricted in the campus of Virginia Tech, VA, and those were selected by experts' survey among various types of nightscape images. The variables for analyzing the characteristics of nightscape images selected were 'preference', 'safety(fear)' and 'clearness'. 'Fixation duration', 'saccade duration', 'scan path length', and 'pupil size' were selected as the eye movement measurements. The results of this study are as follows: The first outcome found was that there were significant differences among the characteristics(preference, safety and clearness) of a nightscape by MANOVA, and these variables were correlated positively by Pearson's correlation. Secondly, there were differences on fixation duration, saccade duration and scan path depending on the nightscape setting statistically. Also, the eye tracking measurement in an open setting was recorded lower than enclosed settings. In the result of a heat map, we found the meaning of the fixated areas on both viewing without intention and viewing intentionally. It turned out that the fixated areas were consistent with the areas the subjects felt preferred and clarity in all of the nightscape images, which means people usually focus on what they prefer and see clearly in a certain nightscape. Based on this result and previous studies, the authors could make a conclusion that eye tracking method can apply to evaluate nightscape settings in terms of analyzing the whole characteristics and finding specific points for the detailed analysis as well. Therefore, these results can contribute by suggesting nightscape planning, implication of the landscape evaluation, and implication of the eye tracking study.

The evaluation of clinical efficacy and longevity of home bleaching without combined application of In-office bleaching (자가미백술 단독사용시 임상적 효능 및 유지력 평가)

  • Shin, Byunk-Gyu;Yang, Sung-Eun
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.387-394
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate the whitening efficacy and longevity of home bleaching. Materials and Methods: A total of 28 patients were divided into either experimental group (Opalescence F; 15% carbamide peroxide) or control group randomly. The patients in experimental group were instructed to wear individual trays applied with bleaching gel for 2 hours a day for 4 weeks. Any treatments weren't applied to the patients in control group. The color measurements of central incisors, lateral incisors & canines of upper and lower arch were recorded at base line, immediately after the finishment of treatmemt (4 weeks), 8 weeks and 12 weeks using Colorimeter (Chroma Meter, 2600d Konica Minolta co.) and Vitapan classical shade guide (Vita Zahnfabrik). Results: A significantly stronger color change was observed for overall teeth samples in experimental group immediately after treatment (at 4 weeks) compared to ones in control group (p < 0.05). There was also a significant difference between baseline and 8 weeks or 12 weeks separately though color rebouncing phenomenon occurred as time went by (p < 0.05). Conclusions: The clinical effecacy and longevity of home bleaching without combined application of in-office bleaching was observed through this experiment.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.