• 제목/요약/키워드: Measurement position

검색결과 2,286건 처리시간 0.033초

영상처리기술을 이용한 건축 구조물의 실시간 변위측정 시스템의 개발 (Development of Real-Time Displacement Measurement System for Multiple Moving Objects of construction structures using Image Processing Techniques)

  • 김성욱;서진호;김상봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.764-769
    • /
    • 2003
  • The paper introduces a development result for displacement measurement system of multiple moving objects based on image processing technique. The image processing method adopts inertia moment theory for obtaining the centroid of the targets and basic processing algorithms of gray, binary, closing, labeling and etc. To get precise displacement measurement in spite of multiple moving targets, a CCD camera with zoom is used and the position of camera is changed by a pan/tilt system. The fiducial marks on the fixed positions are used as the sensing points for the image processing to recognize the position errors in directions of X -Y coordinates. The precise alignment device is pan /tilt of X - Y type and the pan/tilt is controlled by DC servomotors which are driven by 80c196kc microprocessor based controller. The centers of the fiducial marks are obtained by a inertia moment method. By applying the developed precise position control system for multiple targets, the displacement of multiple moving targets are detected automatically and are stored in the database system in a real time. By using database system and internet, displacement data can be confirmed at a great distance and analyzed. The developed system shows the effectiveness such that it realizes the precision about 0.12mm in the position control of X -Y coordinates.

  • PDF

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

무선센서네트워크에서 삼변측량법 기반 이동노드 위치 오차를 줄이는 탐색기법 (Improved Trilateration Method on USN for reducing the Error of a Moving Node Position Measurement)

  • 문형진;정희영;한군희
    • 디지털융복합연구
    • /
    • 제14권5호
    • /
    • pp.301-307
    • /
    • 2016
  • 탄광, 지하실, 지하창고 등 위험한 지역에서 일하는 일군들의 움직임을 비롯한 위치 측정은 안전을 위해 반드시 필요한 기술이다. 위험하고 제한된 환경에서의 USN의 위치 측정 기법들은 다양하게 존재한다. 위치 측정 기법 중에 삼각측량법은 간단하기 때문에 여러 분야에서 많이 적용되고 있다. 하지만 측정기구와 전파 장애 및 물리적 장애로 인해 오차가 발생하여 정확한 위치를 파악하기 어렵다. 본 논문에서는 4개의 Anchor와 움직이는 노드 사이의 거리 정보를 다양하게 활용하여 재계산하여 기존 삼각측량법으로 얻은 위치보다 오차범위를 줄일 수 있는 방법을 제안한다. 또한 제안 기법을 통해 거리 측정하여 움직이는 노드의 위치 즉, 예측점을 계산하였을 때는 기존 삼각측량법보다 계산의 오버로드가 발생하지만 수학적으로 위치측정 오차 범위 계산 시 41%가 향상되었다.

FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발 (Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion)

  • 문기욱;김철승;김지원;이재호;권유리;강동원;강곤;김요한;엄광문
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

The Compensation of Machine Vision Image Distortion

  • Chung, Yi-Chan;Hsu, Yau-Wen;Lin, Yu-Tang;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • 제5권1호
    • /
    • pp.68-84
    • /
    • 2004
  • The measured values of a same object should remain constant regardless of the object's position in the image. In other words, its measured values should not vary as its position in the image changes. However, lens' image distortion, heterogeneous light source, varied angle between the measuring apparatus and the object, and different surroundings where the testing is set up will all cause variation in the measurement of the object when the object's position in the image changes. This research attempts to compensate the machine vision image distortion caused by the object's position in the image by developing the compensation table. The compensation is accomplished by facilitating users to obtain the correcting object and serves the objective of improving the precision of measurement.

실시간 위치추적 시스템에서 높이 오차를 고려한 TDOA 측정치 기반 테일러 급수 설계 방법 (TDOA Measurement Based Taylor Series Design Method Considering Height Error for Real-Time Locating Systems)

  • 강희원;황동환;박찬식
    • 제어로봇시스템학회논문지
    • /
    • 제16권8호
    • /
    • pp.804-809
    • /
    • 2010
  • This paper proposes a Taylor-series design method which reduces the height error of the tag when readers are arranged at the same height in 3-dimensional space. The proposed method consists of two steps. Firstly, the planar position is estimated by the Taylor-series method using the TDOA measurement. Next, the height is estimated from the estimated planar position. In order to show the validity of the proposed method, computer simulations were performed for the static case and linear trajectory of the tag. Results show that the proposed method gives convergent estimated position and better height estimate than the Taylor series method.

비젼 정보를 이용한 이동/작업용 로봇의 정밀제어 (Precision control of a mobile/task robot using visual information)

  • 한만용;이장명
    • 전자공학회논문지S
    • /
    • 제34S권10호
    • /
    • pp.71-79
    • /
    • 1997
  • This paper introduces a methodology of the precise control of a mobile/task robot using visual information captured bythe camera attached at the hand of the task robot. The major problem residing in the precise control of mobile/task robot is providing an accurate and stable base for the task robot through the precise control of mobile robot. On account of uncertainties on the surface, the precise control of mobile robot is not feasible without using external position sensor. In this paper, the methodology for the precise control of mobile robot is proposed, which recognizes the position of mobile robot using the camera attached at the hand of the task robot. While the task robot is approaching to an assembly part, the position of mobile robot is measured using the line correspondence between the image capturesd by the camera and the real assembly part, and using the kinematic transformation from the hand of the task robot to the mobile robot. To verify the solidness of this method, experimental data for the measurement of camera position/orientation and for the precise control of mobile robot using measurement are shown.

  • PDF

CV Joint 측정시스템용 Pre-Position 장치 개발에 관한 연구 (Development of Pre-Position device for CV Joint Measurement System)

  • 김동우;박광수;김봉준;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.156-159
    • /
    • 2005
  • The outer race of CV(constant velocity) joint is an important load-supporting automotive put that transmits torque between the transmission gear box and driving wheel. The outer race is difficult to forge because its shape is very complicated and the required dimensional tolerances are very small. To guarantee the dimensional accuracy of the forged CV Joint, the quick and precise measurement is required to increase the inspection speed of forged products. Therefore in this study, PP(Pre-Position) Device to decrease the inspection time of measuring system has been developed to cope with forging cycle time. The measured inspection time confirms that the PPD is very effective in decreasing inspection time.

  • PDF

적분구를 이용한 PLS 광속측정의 보정계수 산출 및 적용 (Calculation of correction factor in PLS luminous flux measurement with integrating sphere)

  • 이정욱;박경훈;유재규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.13-15
    • /
    • 2006
  • This paper describes the problem generated in PLS luminous flux measurement with integrating sphere. In RS case, we don't use the center position of the sphere but side position for flux test The difference of the lamp position makes the luminous flux difference of same light source. We confirmed the phenomenon with three other kinds of lamps and ensured the repeatability and reliability of this work at two laboratories. finally, the correction factor which should be applied for the PLS test at Side position was calculated.

  • PDF

One Idea on a Three Dimensional Measuring System Using Light Intensity Modulation

  • Fujimoto Ikumatsu;Cho In-Ho;Pak Jeong-Hyeon;Pyoun Young-Sik
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.130-136
    • /
    • 2005
  • A new optical digitizing system for determining the position of a cursor in three dimensions(3D) and an experimental device for its measurement are presented. A semi-passive system using light intensity modulation, a technology that is well known in radar ranging, is employed in order to overcome precision limitations imposed by background light. This system consists of a charge-coupled device camera placed before a rotating mirror and a light-emitting diode whose intensity is modulated. Using a Fresnel pattern for light modulation, it is verified that a substantial improvement of the signal to noise ratio is realized for the background noise and that a resolution of less than a single pixel can be achieved. This opens the doorway to the realization of high precision 3D digitized measurement. We further propose that a 3D position measurement with a monocular optical system can be realized by a numerical experiment if a linear-period modulated waveform is adopted as the light-modulating one.