• Title/Summary/Keyword: Measurement of Vibration Intensity

Search Result 88, Processing Time 0.023 seconds

Measurement of Vibration Intensity of a Semi-Infinite Beam Using the Principle of Reciprocity (가역성 원리를 이용한 반무한보의 진동 인텐시티 측정)

  • 양귀봉;길현권;홍석윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1073-1077
    • /
    • 2001
  • The objective of this paper is to apply an experimental method based on the principle of reciprocity to measuring the structural intensity. Since only one accelerometer is used in this method it has the advantages of shortening measurement time. reducing accelerometer phase error. overcoming the limitation that the situation should be stationary during the experiment. It has been used to measure the vibration intensity of an infinite beam (beam with damped ends) and a semi-infinite beam (beam with simply supported and damped ends). Results showed that the experiment method based on the principle of reciprocity can be effectively used to measure the structural intensity.

  • PDF

A KS Draft of the Measurement of Sound Insulation in Buildings and of Building Elements Using Sound Intensity: Laboratory Conditions (Sound Intensity를 이용한 건물부재의 차음성능 실험실 측정방법 KS 규격 제정안)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.961-964
    • /
    • 2002
  • A KS draft of the measurement of sound insulation in buildings and of building elements using sound intensity: laboratory conditions is proposed. It is based on ISO 15186-1. In order to make it as a KS, some contents are carefully tested.

  • PDF

Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method (Structural Intensity 법을 이용한 구조체의 진동전달량 측정)

  • ;Tichy, Jiri
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF

Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode (광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정)

  • Yoo, W.J.;Lee, G.S.;Kim, J.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF

Application of Sound Intensity Camera for the Noise Source Analysis (소음원 규명을 위한 음향 인텐시티 카메라 응용)

  • Lee, Chang-Myung;Bae, Young-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.229-230
    • /
    • 2009
  • A method is suggested for the noise source identification using the sound intensity method. The suggested method does not need to install the grid using wire or thread during the sound intensity measurement for the noise source identification. It utilizes a camera to show the grid on the screen not installing the real grid for the sound intensity method.

  • PDF

Simultaneous Measurement of Strain and High Frequency Vibration of Composite Main Wing Model (복합재 주 날개 모델의 변형률과 진동의 동시 측정)

  • Song, Ji-Yong;Yoon, Hyuk-Jin;Park, Sang-Wuk;Park, Sang-Oh;Kim, Chon-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.185-189
    • /
    • 2005
  • For the simultaneous measurement of strain and vibration signal, a fiber Bragg grating sensor system with a dual demodulator was proposed. One demodulator using a tunable Fabry-Perot filter could measure low-frequency signal such as strain and the other demodulator using a coarse wavelength division multiplexer could detect high-frequency signal such as vibration signal using intensity demodulation method. In order to measure strain and vibration of the composite main wing model under static loading a real time monitoring program was developed. Also using intensity demodulation of CWDM, sensitivity and resolution at high frequency vibration were evaluated.

  • PDF

Measurement of Near Field Sound Intensity and Loss Factor Using Plate Intensity Measurement (평판 인텐시티 측정을 통한 근접장 음향 인텐시티와 손실 계수 측정법)

  • 김용조;김양한
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.589-596
    • /
    • 1997
  • A energy equation for a thin plate and surrounding fluid is derived. The equation essentially determines the relation between internal loss of thin plate, energy of acoustic radiation, and structure intensity. We attempted to use this relation to measure internal loss of thin plate. The significance of this approach is that internal loss at any point of a thin plate can be measured. The quality of this measure is dicated by the accuracy of associated measurement systems such as structure and acoustic intensity measurements. A strain gauge bridge system has been developed to measure structure intensity of thin plate. Its performance is tested by experiments.

  • PDF

Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method (복소음향인텐시티법을 이용한 HVAC의 소음원 검출)

  • Yang, Jeong-Jik;Lee, Dong-Ju
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

A study on the identification of dynamic characteristics of tennis racket by acoustic intensity method (음향 인텐시터법을 이용한 테니스 라켓의 동특성에 관한 연구)

  • 오재응;이유엽;염성하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.601-610
    • /
    • 1986
  • The acoustic intensity in the very near field of a vibrating surface reveals information about the location of sound sources and sinks. A system model of tennis racket was developed from simultaneous measurement of excitation force, surface vibration and the near field sound pressure. The characteristics of structural dynamics were obtained by standard experimental modal analysis techniques while the sound radiation characteristics were determined by estimating the acoustic intensity. In this paper, the information about vibration behviour was obtained by acoustic intensity method and some, experiments for verification were carried out. Close correlation was found between experimentally determined acoustic intensity and vibration mode patterns of the tennis racket.

Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity (음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어)

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Koo, Ja-Choon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF