• 제목/요약/키워드: Measurement of Radioactivity

검색결과 131건 처리시간 0.04초

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

실내 환경 모니터링을 위한 다중 방사능계측 시스템 설계 (Multi-Radioactivity Measurement System Design for Indoor Environmental Monitoring)

  • 사공병일;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.459-461
    • /
    • 2022
  • 본 논문에서는 실내 환경에서 검출되는 방사능을 측정하기 위한 계측 시스템을 제시한다. 일반 가정, 작업장, 연구소 등 다양한 공간에서 발생되는 방사능을 측정하고 이에 대한 예방을 위함이다. 다중 방사능 센서를 이용해서 여러 공간을 동시에 측정한다. 측정된 방사능 데이터는 지그비를 통해서 실시간으로 PC로 전달하여 모니터링하는 시스템이다. 소량의 방사능이라고 하더라고 만성 피폭으로부터의 예방을 위해 연구소 또는 작업장 같은 방사능 노출이 예상되는 곳은 필수적으로 설치되어야 한다고 생각된다.

  • PDF

방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략 (Counting Strategies in Radioactivity Measurement for the Monitoring and Screening)

  • 서경원
    • Journal of Radiation Protection and Research
    • /
    • 제23권2호
    • /
    • pp.65-74
    • /
    • 1998
  • 저 준위방사능 계측에서 가장 기본적으로 요구되는 것이 최적 측정시간의 결정이다. 최적화된 계측전략으로 측정시간을 결정하기 위하여 측정시간을 고정하는 방법, 측정값을 고정하는 방법, 시료와 자연계수율 또는 기준준위를 비교하여 측정하는 방법을 비교 검토하는 결정식을 도출하였다. 이 계측전략에서 기기에 주어진 측정조건 즉, 검출기의 효율, 측정기의 용량, 측정기의 최대 및 평균 자연계수율과 관련기준 즉, 기준준위, 검출한계 등을 만족하는 측정시간이 결정된다. 계측전략은 측정시 주어진 조건에서 방사능 존재확인과 정량분석에 대한 시료의 최적 측정시간의 결정을 편리하게 함으로써 일상의 저준위방사능 측정에 유용하게 사용될 것이다.

  • PDF

발전용원자로에서 뱃치방식으로 배출되는 액체상 방사성물질의 방사능 평가결과에 대한 불확도 해석 (Uncertainty Analysis of the Calculated Radioactivity in Liquid Effluent Released as Batch Mode from a Nuclear Power Plant)

  • 정재학;박원재
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.562-571
    • /
    • 2003
  • 발전용원자로에서 뱃치방식으로 환경으로 배출된 액체유출물 내에 함유된 방사능 평가 결과에 오차를 유발하는 시료채취, 제조, 방사능 계측, 유출물 배출체적 측정 등 다양한 인자를 분석하였다. 환경배출 방사능 평가에 포함된 많은 인자들은 단일 측정에 의해 얻어지고 환경배출 방사능의 참값을 알 수 없음에 따라, 평가결과의 오차를 예측하는 것은 원칙적으로 불가능하다. 이에 따라 1993년 ISO가 권고한 측정의 불확도 표현지침에 근거하여 액체폐기물 배출방사능에 대한 불확도 평가모델을 수립하고 가상적인 조건에 대한 액체유출물 환경배출 방사능 평가결과의 불확도를 평가하였다. 그 결과, 액체유출물을 통한 환경배출 방사능 평가결과에 불확도를 유발하는 인자의 상대적인 기여도는 배출폐액의 체적, 시료의 체적, 총방사능 계측값의 순서를 갖는 것으로 나타났다. 또한 개별 변수의 확률분포와 특성값을 토대로 몬테칼로 모사법을 적용하여 최종 환경배출 방사능 평가결과의 확률분포를 해석함으로써, 지금까지 단일 값을 평가 및 보고되었던 발전용 원자로의 액체상 방사성물질 환경배출량이 실제로는 일정한 확률분포를 갖고 있음을 확인하였다.

  • PDF

갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가 (The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement)

  • 이현국;강현수;양승오;한만석
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

갑상샘 섭취율 검사 시 대퇴부를 이용한 배후방사능 계측을 위한 2가지 측정 고찰 (Two Measurement Considerations for Counting of Background Radioactivity using the Thigh during Thyroid Uptake Rate Test)

  • 도용호;조영권
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.533-538
    • /
    • 2021
  • 갑상샘 섭취율 측정을 위해 과산화테크네슘을 사용하고 있다. 대퇴부의 배후방사능 측정 시 무릎에서 골반 쪽으로 10 cm 위의 위치에서 검출기와 대퇴부의 거리를 20 cm, 25 cm 위치에서 병원들마다 서로 다른 거리에서 측정하고 있다. 두 거리에서 갑상샘 섭취율 측정을 정량 분석하여 갑상샘 섭취율을 구함에 있어서 유효성의 차이를 연구 하고자 하였다. 결과로써 50명의 대퇴부 20 cm에서 측정한 평균 갑상샘 섭취율은 3.532±4.312%로 나타났으며 25 cm에서 측정한 평균 갑상샘 섭취율은 3.680±4.304%로 나타났다. 갑상샘 섭취율 검사 결과를 통하여 20 cm 거리에서 측정된 대퇴부의 배후방사능 값이 상대적으로 25 cm 거리에서 측정된 배후방사능 값 보다 높게 측정되어 결과적으로 갑상샘 섭취율이 0.148% 낮게 나왔으며 배후방사능 측정을 위한 일정한 거리에서의 측정이 중요하다고 판단된다.

고리1호기 가동이력을 고려한 손상 배플포머볼트 방사화 계산 (Radioactivity Calculation Considering Kori Unit 1 Operation History for the Defected Baffle Former Bolts)

  • 맹영재;이현철;이명호;황성식;오승진;장윤석
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.20-26
    • /
    • 2023
  • The defected baffle former bolts of Kori unit 1 were withdrawn to analyze the cause of damage and gamma-ray measurement is being scheduled. Prior to that, in order to calculate the specific radioactivity value of the baffle former bolt, a radioactivity calculation method considering the actual operation history of the nuclear power plant is introduced and the calculation results are shown. In particular, the radioactivity calculation method considering the operation history is obtained by defining the monthly contribution factor from the actual monthly operation history. As a result, the results considering operation history are 16-28% lower than the general radioactivity calculation results. These results can contribute to establish a reasonable but economical strategy when planning nuclear power plant decommissioning.

규제해제 대상 방사성 금속 폐기물 최종잔류방사능 측정법 (Measurement Method of Final Residual Radioactivity of Radioactive Metallic Waste for Clearance)

  • 서범경;지영용;홍상범;이근우;문제권
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.228-233
    • /
    • 2013
  • 세계적으로 원전의 가동 년수 증가로 인하여 증기발생기와 같은 중요 설비의 교체가 지속적으로 이루어지고 있으며, 해체 시에는 대량의 방사성 금속 폐기물이 일시에 발생한다. 이러한 방사성 폐기물을 규제해제 후에 재활용하기 위해서는 정확한 잔류방사능을 측정하여야 한다. 그러나, 원자력시설에서 발생되는 금속 폐기물은 형상이 복잡하고, 재질별 특성이 다양하기 때문에 잔류방사능을 정확히 측정하기가 어렵다. 본 연구에서는 방사성 금속 폐기물의 정확한 잔류방사능을 측정하기 위한 절차를 수립하였고, 오염 대상 선원항 평가, 시료 대표성 확보 방안, 대면적 오염도 측정 장치 제작 및 밀도에 의한 자체흡수 보정인자 등을 평가하였다. 특히, 복잡한 구조의 금속 폐기물에 대하여 시료의 대표성을 확보하기 위하여 용융시킨 후 단순한 형태의 시료를 제조하였으며, 금속의 밀도 차이에 따른 보정인자를 결정하여 방사능 측정 결과의 신뢰성을 향상시켰다.

담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가 (Analysis of Radioactivity Concentrations in Cigarette Smoke and Tobacco Risk Assessment)

  • 이세령;이상복;김정윤;김지민;방예진;이두석;조형준;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.489-494
    • /
    • 2021
  • In this study, radioactivity quantitative analysis was performed on radon contained in cigarette, and the effective dose was calculated using the result value to determine the amount of exposure caused by smoking. A total of 5 types of cigarettes were sampled. Cigarette smoke was collected by using activated carbon, and tobacco were measured by homogenizing for quantitative analysis. For each sample, Bi-214 and Pb-214 were subjected to gamma nuclide analysis to observe the uranium-based radioactive material contained in cigarette, and a measurement time of 30,000 seconds was set for the sample based on the results of previous studies. As a result of measuring the radioactivity of tobacco, a maximum of 0.715 Bq/kg was derived, and in the case of cigarette smoke measured using activated carbon, a maximum of 3.652 Bq/kg was derived. Using this measurement, the average effective dose to the lungs is 0.938 mSv/y, and it was found that there is a possibility of receiving exposure up to 1.099 mSv/y depending on the type of tobacco. It was found that the exposure dose due to cigarette occupies a large proportion of the annual effective dose limit for the general public. Therefore, more diverse studies on radioactive substances in cigarette are needed, and measures to monitor and reduce the incidental exposure to radon should be established.