• Title/Summary/Keyword: Measurement of Radioactivity

Search Result 131, Processing Time 0.022 seconds

Choline-Lipid Release from Normal and Transformed Cells

  • Hong, Seong-Tshool;Jang, Yong-Suk;Park, Kie-In
    • BMB Reports
    • /
    • v.29 no.1
    • /
    • pp.73-80
    • /
    • 1996
  • The effect of albumin on phosphatidylcholine (PC) metabolism in Hep-G2, 3T3-H.ras, and 3T3 cells pre-labelled with [Me-$^3H$]choline was studied. The [$^3H$]choline was more efficiently taken up and incorporated into cellular phospholipids in 3T3-H.ras cells than in Hep-G2 and 3T3 cells. In each of the three cell lines, most of the [$^3H$]choline metabolized into the phospholipids was incorporated into PC and only minor was incorporated into lysophosphatidylcholine (LPC). Bovine serum albumin stimulated the release of [$^3H$]LPC and [$^3H$]PC from each of the three cell lines pre-labelled with [$^3H$]choline. [$^3H$]PC was also released in the absence of albumin but [$^3H$]LPC was not. The efficiency of LPC secretion represented as the proportion of medium [$^3H$]LPC to cellular [$^3H$]choline lipid during a chase period is approximately 9 to 14 times greater in 3T3 cells compared with the transformed 3T3-H.ras and Hep-G2 cells. A similar comparison of published data for rat hepatocytes with Hep-G2 shows secretion to be 35~75 times greater from the rat hepatocytes than from Hep-G2. Also, PC secretion from 3T3 cells was 1.6 times more effective than from 3T3-H.ras, whereas rat hepatocytes secrete PC 2.8~3.8 times more effectively than does Hep-G2. The measurement of specific radioactivity of cellular PC in pre-labelled 3T3 cells showed it to be similar to that of the secreted PC. However, the specific radioactivity of secreted LPC was markedly lower than that of the cellular PC, which suggests that LPC is being secreted from a PC pool distinct from that used for PC secretion.

  • PDF

Internal Radiation Dosimetry using Nuclear Medicine Imaging in Radionuclide Therapy (방사성핵종 이용 치료에서 핵의학영상을 이용한 흡수선량평가)

  • Kim, Kyeong-Min;Byun, Byun-Hyun;Cheon, Gi-Jeong;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.265-271
    • /
    • 2007
  • Radionuclide therapy has been an important field in nuclear medicine. In radionuclide therapy, relevant evaluation of Internally absorbed dose is essential for the achievement of efficient and sufficient treatment of incurable disease, and can be accomplish by means of accurate measurement of radioactivity in body and its changes with time. Recently, the advances of nuclear medicine imaging and multi modality imaging processing techniques can provide change of more accurate and easier measurement of the measures commented above, in cooperation of conventional imaging based approaches. in this review, basic concept for internal dosimetry using nuclear medicine imaging is summarized with several check points which should be considered In real practice.

Study on Measurements in Thyroid Uptake Rate Test (갑상선섭취율검사시(甲狀腺攝取率檢査時) 측정조건(測定條件)에 관(關)한 조사연구(調査硏究))

  • Kyong, Kwang-Hyon;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1981
  • This study was conducted, during the period of 20-30th, July in 1981, to survey measurement methods in thyroid uptake rate test in Seoul city. The results were summarized as follows: 1. For the great part of nuclear medcine department, a mount of radioiodine($^{131}I$) administrated to the patients was $50-100{\mu}Ci$ in thyroid uptake rate test. 2. Distribution of scintillation, counter with crystal size of $1\frac{1}{2}inch$ was 43%, 3inch(22%), 2.5inch(14%) and $2\frac{1}{2}inch$ was 7% in RAI uptake rate test. 3. When RAI uptake rate test was performed, distribution of collimator in use was flat field type collimator(78%) in general and cylindrical type collimator was 22%. 4. High voltage applied to the P-M tube was $900{\sim}1000V$(50%) and most units provided $3{\sim}15%$ of the window range for the $^{131}I$ peak $\gamma-ray$ energy. 5. Distribution on the use of neck phantom for measurements standard solution was 57% and distribution of b filter in use for room background counts and extrathyroidal tissue was 43% and 50%. 6. The distance between the counter and the source was 25cm(58%) in measuring radioactivity of standard solution, thyroid tissue and background radioactivity count. 7. The early uptake measurements(2, 4, 6 hours) are done after administration of the radioiodine dose and also 24-hour and 48-hour uptake measurements are done in routine test.

  • PDF

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.

Development of Micro-Blast Type Scabbling Technology for Contaminated Concrete Structure in Nuclear Power Plant Decommissioning

  • Lee, Kyungho;Chung, Sewon;Park, Kihyun;Park, SeongHee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.1
    • /
    • pp.99-110
    • /
    • 2022
  • In decommissioning a nuclear power plant, numerous concrete structures need to be demolished and decontaminated. Although concrete decontamination technologies have been developed globally, concrete cutting remains problematic due to the secondary waste production and dispersion risk from concrete scabbling. To minimize workers' radiation exposure and secondary waste in dismantling and decontaminating concrete structures, the following conceptual designs were developed. A micro-blast type scabbling technology using explosive materials and a multi-dimensional contamination measurement and artificial intelligence (AI) mapping technology capable of identifying the contamination status of concrete surfaces. Trials revealed that this technology has several merits, including nuclide identification of more than 5 nuclides, radioactivity measurement capability of 0.1-107 Bq·g-1, 1.5 kg robot weight for easy handling, 10 cm robot self-running capability, 100% detonator performance, decontamination factor (DF) of 100 and 8,000 cm2·hr-1 decontamination speed, better than that of TWI (7,500 cm2·hr-1). Hence, the micro-blast type scabbling technology is a suitable method for concrete decontamination. As the Korean explosives industry is well developed and robot and mapping systems are supported by government research and development, this scabbling technology can efficiently aid the Korean decommissioning industry.

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

The Variation of Radiocarbon-14 Content in the Atmosphere

  • Kyung Rin Yang
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.370-377
    • /
    • 1971
  • The Carbon-14 content in surface air at Seoul, Korea, was measured from February 1970 to August 1971 and a Larix Leptolepis, Gordon tree (Ip-Gal Namu) grown at Kwang-Nung, Kyunggi-Do, Korea, having 37 growth rings, was assayde for $^{14}C$. From the results of the surface air study, it was calculated that during the above period the inventory of excess $^{14}C$ in the atmosphere decreased with a half-time of 4.6 years. The overall yearly decrease was also checked. The tree-ring study showed that the tree's atmosphere was affected by $^{14}C$ from nuclear tests after 1956. In one study, atmospheric $CO^2$ samples were collected bi-monthly by the absorption of $CO^2$ in alkaline hydroxide solution. In the other, 5 year annual growth rings were assayed for radiocarbon. For the radioactivity measurement, carbon atoms in samples were converted to carbon atoms of benzene. The resulting benzene was taken as primary solvent for liquid scintillation counting.

  • PDF

Development of Remote Data Analysis System for the Joint Use of Equipments (분석기기지원을 위한 원격 데이터 분석 시스템 개발)

  • 최인식
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.3
    • /
    • pp.94-106
    • /
    • 1999
  • In Korea Basic Science Institute(KBSI) the remote data analysis system is developed for the joint use of advanced equipments. This system enables the researchers to access the datas which are produced at KBSI and analyse them by Java program on the Web,. Except Web browser such as Internet Explorer or Netscape Navigator no additional softwares are required for analysing data. We have developed remote data analysis systems for five major equipments which KBSI supports for the researchers, The systems which are developed are those for NMR spectrometer High Reso-lution Tandem mass Spectrometer Microscopic Imaging System DNA Sequencer and Natural Ra-dioactivity Measruement System, These programs work on any computer platform and any operat-ing system only if the internet is available. This remote data analysis system will be served as a part of Collaboratory the remote collaborative system.

  • PDF