• Title/Summary/Keyword: Measurement methods

Search Result 8,209, Processing Time 0.045 seconds

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

The Purpose and background of this study (노인질환에 대한 한양방동시종합검진 결과에 대한 보고)

  • Gwon, Gyeong-Suk;Lee, Tae-Hwan;Song, Jeong-Mo;Kim, In-Seop;Yun, Ho-Yeong;Im, Jun-Gyu
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.9-27
    • /
    • 1994
  • This study is to analyze of senile disease status and the social problem according to increased old ages, and then to find distributions of old man's diseases and health status efficiency of oriental-occidental contemporary health examination. And it is the first oriental-occidental contemporary health examination of old man performed by JeonJu Woosuk University Oriental Medicine Hospital and Woosuk-Clinic in nation. Methods The objects in this research are 641's old man of KimJe Gun's over 60's years performed medical examination at JeonJu Woosuk University Oriental- Mmedicine-Hospital and Woosuk-Clinic by oriental-occidental medical contemporary exam., from 1994, 24th June till 1994. 13th July. The 1st occident medical examination methods were consisted of chest x-ray check. blood and urine exam., measurement of blood pressure, visual power and audiometry. The Oriental medical examination methods were consisted of four diagnostics (望,聞,問,切), present illness. chief complaint, past history, families history, social history by question and SA Sang constitution test index. The results and conclusions The results and conclusions are the next: 1. In order of distribution. the athletic disease (75.8%),the digestive disease(43.4%), the circulatory disease(41.5%), the respiratory disease(22.3%), EENT disease(8.1%), the endocrinopathy(5.6%), and the genito-urinary disease(5.3%) are the results of the object about 641's old man, by the oriental-occidental medicine's contemporay exam. 2. Distribution of disease distiction are lumbago. gastritis and peptic ulcer. knee joint pain. heart disease. hypertension. chronic bronchitis. asthma. anemia. DM. Tbc. visual disturbance. CVA. etc in order. 3. Disease distribution according to age is almost high incident in 60-75years. Disease incidence is decreased except E.E.N.T disease in over 76years. 4. The relationships of disease and family history are: the 25.0% of CVA pts. has family history and the 11.6% of hypertension pts has family history. so they showed high relative family history. In addition the 5.6% of TBC pts. and the 2.6% of DM pts. have family history. 5. The relationships of disease and drinking are: Drinking proportion is the 36.4% in respiratory disease pts. the 34.7% in hypertension pts. the 33.3% in heart disease pts.. the 28.4% in digestive disease pts.. but because of no surveying drinking amount we can't know the absolut relationships of disease and drinking. 6. The relationships of Disease and smoking are: Smoking proportion is the 44.1% in respiratory disease pts.. the 38.0% in Heart disease pts.. the 29.8% in Hypertension pts.. but because of no surveying of smoking amount. we can't know the absolut relationships of disease and smoking. 7. Distribution of Sasang constitution is : Tae-eum-in 44.8%. So-yang-in 30.7%. So-eum-in 24.6%. Tae-yang-in 0.0%. And disease distribution of Sasang constitution distinction is ; Tae-eum-in has high incidence of circulation disease(50.0%) and respiratory disease(23.1%).So-yang-in has high incidence of athletics disease(77.7%) and EENT disease(12.2%), So-eum-in has high incidence of digestive disease(65.8%). 8. Distribution of abnormal result in occidental medical examination and oriental-occidental contemporal exam result is considerably different. This is the reason of needing oriental medicine exam, for characteristics of Senile. I think that the oriental-occidental contemporary examination in old man is much more effecient than only occident medical examination. This oriental-occidental contemporary examination has many defects because it is the first practice. To participate in the public health program efficiently. I think that we must improve lots of problems and present the model of the oriental-occidental contemporary examination and the project of oriental medicine's for public health.

  • PDF

Halitosis and Related Factors among Rural Residents (농촌지역 주민들의 구취실태와 유발요인)

  • Lee, Young-Ok;Hong, Jung-Pyo;Lee, Tae-Yong
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.157-175
    • /
    • 2007
  • This study was conducted through an interview process in which questionnaires were administered to 293 people. The questionnaires related to the behaviors of oral hygiene care, and disease history related to halitosis, and status of halitosis, halitosis measurement, oral examination, and caries activity tests such as the snyder test, Salivary flow rate test, and Salivary buffering capacity test. Our sample was taken from 293 rural residents within the period from 4th to 21st of January 2006. This was done in order to provide basic data to prepare both policies of halitosis prevention and a device to efficiently measure halitosis status and investigate the factors related therein. The major findings of this study results are as follows: 1. As for frequency of tooth brushing, twice a day occupied the greatest portion at 46.1 % Women exceeded men in frequency of tooth brushing. Tongue brushing everyday produced a 25.6 % result among subjects and The use of auxiliary oral hygiene devices occupied 9.2 %. 2. As for degree of usual self-awareness of halitosis: 62.5 %. This result also demonstrate that the severest time of self-awareness in regards to halitosis is wake up time in the morning. The time period produced the highest portion of 72.7 % in times of self-awareness. In terms of the area in which halitosis was observed, gum resulted in 23.0 %. As for types of halitosis, fetid smell was the most frequent at 37.2 %. 3. As for the result of halitosis measurement, values of OG less than 50 ppm occupied 54.3 % and $50{\sim}100ppm$ occupied 41.6 %. As for $NH_3$ values, $20{\sim}60ppm$ showed the highest value range of 52.6 %. 4. As for OG per disease history related to halitosis, values of OG were significantly high in the ranges of $50{\sim}100ppm$ within family history groups of food impaction by dental caries, diabetes mellitus and halitosis. As for values of $NH_3$, there showed a significant difference in respiratory system disease groups. 5 Value range of OG per ordinary halitosis self-awareness degree: values ranging less than 50 ppm were recorded at 55.9 % from the group realizing not aware of smell. 57.5 % from groups only realizing sometimes, while values range of $50{\sim}100ppm$ were recorded at 52.0 % from groups always aware of smell. 63.6 % from groups always strongly aware of smell. Meanwhile as for the values ranges of $NH_3$, $20{\sim}60ppm$. they occupied high portions for all groups of exams. 6. Values of OG per oral examination: the more pulp-exposed teeth and food impaction and the higher the tongue plaque index, values of OG increased within the range of $50{\sim}100ppm$. As for values of $NH_3$, the more prosthetic teeth and the higher the tongue plaque index, this value increased significantly, and the values increased up to no less than 60 ppm for groups of mandibular partial denture. 7. Within the realm of caries activity test: as for the Snyder test, high activity was highest by 43.0 % wherewith the higher the activity of acidogenic bacteria the higher the OG values. As for the salivary flow rate test, the number of cases below 8.0 ml showed the highest tendency by 62.5 %. The larger the salivary flow rate the more decreased OG values distribution. As for the salivary buffering capacity test, $6{\sim}10$ drops of 0.1N lactic acid showed the overwhelming trend by 58.7 % whereby the higher the salivary buffering capacity the greater distribution occupancy ratio of OG values below 50 ppm which is scentless to on ordinary person. 8. As for the correlation between oral environment and halitosis, OG showed the positive correlation with pulp exposed teeth, filled teeth, present teeth, tongue plaque index, and food impaction, while the negative correlation with salivary flow rate and prosthetic teeth. $NH_3$ showed a positive correlation with prosthetic teeth and frequency of tooth brushing, while decayed teeth was negative correlation. 9. As for the multiple regression analysis result, there have been selected female, pulp exposed teeth, prosthetic teeth, food impaction, salivary flow rate, tongue plaque index and severe activities in the Snyder test as factors affecting OG wherein explanatory power on it was 45.1 %. There have been selected females, pulp exposed teeth, tongue plaque index, and prosthetic teeth as factors affecting on $NH_3$ wherein explanatory power on it was 6.6 %. With the aforementioned results in mind, the status of halitosis among rural residents is considered to bare a close relation with oral environments and other factors related to halitosis such as the Snyder test from caries activity test, and salivary flow rate test. For the prevention of halitosis of residents in rural areas, we have to focus on correct tooth brushing methods and tongue brushing, with using auxiliary oral hygiene devices to remove fur of tongue plaque and food impaction. Also, when the cause and ingredients of halitosis are diverse and complex, in order to analyze exactly the factors of individual halitosis development, we need continuous and systematic study in order to provide rural residents with programs of oral hygiene education and encourage the use of dental hygienists in public health centers.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Clinical Usefulness and the Accuracy of Korean Reference Equation for Diffusing Capacity (한국인 폐확산능 정상예측식의 임상적 유용성과 정확성)

  • Ra, Seung Won;Park, Tai Sun;Hong, Yoonki;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Background: Park et al. developed the Korean reference equation for the measurement of diffusing capacity in 1985. However, the equation has not been widely used in Korea and foreign reference equations have been popularly used. We intended to compare the clinical usefulness and the accuracy of the the Korean reference equation (Park's equation) with that of the foreign equation (Burrows' equation) that is commonly used in Korea. Methods: 1. Evaluation of clinical usefulness; Among 1,584 patients who underwent diffusing capacity ($D_LCO$) at the Asan Medical Center from July to December 2006, group A subjects included 276 patients who had different interpretations of $D_LCO$ in trials employing Burrows' equation and Park's equation. Clinical assessment was decided by consensus of two respiratory physicians. In order to evaluate the clinical usefulness of Burrows' equation and Park's equation, agreement of clinical assessment and $D_LCO$ interpretation were measured. 2. Evaluation of accuracy; Group B subjects were 81 patients with interstitial lung disease (ILD) and 39 normal subjects. The 81 ILD patients were diagnosed following a surgical lung biopsy. The accuracy of diagnosing ILD as well as sensitivity and specificity were evaluated according to the use of the reference equations (Burrows' equation and Park's equation) for $D_LCO$. Results: Agreement between clinical assessment and interpretation of $D_LCO$ was 22% for the use of Burrows' equation and 78% for the use of Park's equation. The sensitivity and specificity of the Burrows' equation for diagnosing ILD were 64.2% and 100%. The sensitivity and specificity of the Park's equation for diagnosing ILD were 90.1% and 100%. The sensitivity of the Park's equation for diagnosing ILD was significantly higher than that of Burrows' equation (p<0.001). Conclusion: The Korean reference equation (Park's equation) was more clinically useful and had higher sensitivity for diagnosing ILD than the foreign reference equation (Burrows' equation).

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF