• 제목/요약/키워드: Measurement methods

Search Result 8,149, Processing Time 0.049 seconds

Evaluation of Human Factors for the Next-Generation Displays: A Review of Subjective and Objective Measurement Methods

  • Mun, Sungchul;Park, Min-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.207-215
    • /
    • 2013
  • Objective: This study aimed to investigate important human factors that should be considered when developing ultra-high definition TVs by reviewing measurement methods and main characteristics of ultra-high definition displays. Background: Although much attention has been paid to high-definition displays, there have been few studies for systematically evaluating human factors. Method: In order to determine human factors to be considered in developing human-friendly displays, we reviewed subjective and objective measurement methods to figure out the current limitations and establish a guideline for developing human-centered ultra-high definition TVs. In doing so, pros and cons of both subjective and objective measurement methods for assessing humans factors were discussed and specific aspects of ultra-high definition displays were also investigated in the literature. Results: Hazardous effects such as visually-induced motion sickness, visual fatigue, and mental fatigue in the brain caused by undesirable TV viewing are induced by not only temporal decay of visual function but also cognitive load in processing sophisticated external information. There has been a growing evidence that individual differences in visual and cognitive ability to process external information can make contrary responses after exposing to the same viewing situation. A wide vision, ultra-high definition TVs provide, can has positive and negative influences on viewers depending on their individual characteristics. Conclusion: Integrated measurement methods capable of considering individual differences in human visual system are required to clearly determine potential effects of super-high vision displays with a wide view on humans. All of brainwaves, autonomic responses, eye functions, and psychological responses should be simultaneously examined and correlated. Application: The results obtained in this review are expected to be a guideline for determining optimized viewing factors of ultra-high definition displays and accelerating successful penetration of the next-generation displays into our daily life.

A Study on Precision Measurement of Rock Joint Using 3D-Laser Scanner (3D-Laser scanner를 이용한 암반 절리의 정밀측정에 관한 연구)

  • 이승호;황영철;김세현;심석래;정태영
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.103-111
    • /
    • 2004
  • The existing methods that can be adopted for measuring joints involve either to use borehole or photogrammetry. Due to restricted space, acquisition of data in limited area, and measurement errors, above methods have limitations acquiring the objective and correct results. To get over defects of existing joint measurement methods, joints have been measured using 3D-Laser scanner with accuracy and efficiency. This research aims to investigate an accuracy and applicabiliy of 3D-Laser scanner for measuring rock slope joints. Measurement of rock slope joints has been executed using 3D-Laser scanner & clinometer and then, results from both methods are compared. Results from both methods indicate that they show nearly equal features for joint distributions and numbers of joint information obtained by 3D-Laser scanner are much more than ones measured using clinomer. Therefore, 3D-Laser scanner turns out to be very effective by the fact that it contributes to reduce investigation costs & periods, objectify data from rock slope joints.

Vibration Measurements of Large-Scale Structure Using Laser and High-Speed CCD Camera (레이저와 고속 CCD 카메라를 이용한 대형구조물의 진동계측)

  • 이창복;안세호;양성훈;염정원;강동욱;김기두
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1104-1112
    • /
    • 2004
  • In this paper, we establish measurement methods of vibration frequency for three-dimensional behavior measurement of large-scale structure using laser and high-speed CCD camera. We project the diode laser having a smaller fluctuation on the object plane attached to the structure and measure the displacement of the structure using a precise relative measurement algorithm. When we use high-speed(120 frames/sec) CCD camera, we can measure the vibration frequency having the uncertainty within 0.5% by taking FFT on the displacement, from 0Hz to 40Hz. And we also confirm the reliability and economical string of the suggested measurement method of vibration frequency of the structure by showing the accuracy of displacement measurement using laser is comparable to that of relative positioning methods using GPS.

Standardized Progress Measurement Package (건설진도율 산정을 위한 진도관리단위에 관한 연구)

  • Jung Youngsoo;Kang Seunghee;Chin Sangyoon;Kim Yeasang;Chung Moonhun;Park Soonchan
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.565-570
    • /
    • 2004
  • The construction Progress is widely used 3s a critical index for effective project management. However, the methods, structure, data, and accuracy of progress measurement may vary depending on specific characteristics of the project, organization, or location. Even in an organization, different projects may utilize different measurement methods to effectively achieve their own management purpose. The excessive effort required to manipulate very detailed progress data is also an issue Therefore the purpose of this study is to dove]op an automated progress measurement model utilizing standard progress measurement package (SPMP).

  • PDF

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Study on the Establishment of Large Building Airtightness Measurement Standards (대규모 건물의 기밀성능 측정기준 수립에 관한 연구)

  • Lee, Dong-Seok;Ji, Kyung-Hwan;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Evaluation of Indirect Methods of Engine Torque Measurement (엔진 토크의 간접적(間接的)인 측정(測定) 방법(方法)에 관한 연구(硏究))

  • Ryu, K.H.;Kang, S.B.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 1991
  • This study was carried out to evaluate indirect methods of engine torque measurement. Three indirect methods based on throttle valve opening, exhaust gas temperature and inlet air pressure were compared. The indirect method based on throttle valve opening appeared to be the most satisfactory in terms of accuracy and response time. The discrepancies between the direct method and the indirect method based on throttle valve opening in measuring engine torque were 2% on t he average.

  • PDF

A Comparison of Collection Concentrations Based on Airborne Toluene Diisocyanates Measurement Methods (공기 중 Toluene diisocyanates 측정방법에 따른 포집농도 비교)

  • Park, Hyung-Sung;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.341-347
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the differences in airborne TDI concentrations based on the filter collection method and liquid collection method and to compare airborne TDIs concentrations by sampling method change when using the filter collection method in the spray-painting process. Methods: For the sample measurement, the filter collection method(OSHA#42) and liquid collection method(NIOSH#5522) were used; for the sampling method, the full-period single sampling and full-period consecutive sampling methods were used. The samples were collected in spray-painting and drying process locations. Results: In all samples collected from the spray-painting and drying process locations through the filter collection and liquid collection methods, greater amounts of 2,6-TDI than 2,4-TDI were detected. When the TDI collection concentrations based on the sampling methods were compared, the concentrations of 2,4-TDI and 2,6-TDI collected by the consecutive sampling method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the single sampling method for both the filter collection method and liquid collection method used in the spray-painting process. These differences were statistically significant. Conclusions: When TDI collection concentrations based on the sample measurement methods were compared, the concentration of 2,4-TDI and 2,6-TDI collected through the liquid collection method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the filter collection method, and the differences were statistically significant. In the drying process, no difference was shown in the collection concentrations of 2,4-TDI and 2,6-TDI with the two measurement methods.

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF