DOI QR코드

DOI QR Code

Study on the Establishment of Large Building Airtightness Measurement Standards

대규모 건물의 기밀성능 측정기준 수립에 관한 연구

  • Lee, Dong-Seok (Graduate school, Division of Architecture, Inha University) ;
  • Ji, Kyung-Hwan (Graduate school, Division of Architecture, Inha University) ;
  • Jo, Jae-Hun (Division of Architecture, Inha University)
  • Received : 2013.01.05
  • Accepted : 2014.02.25
  • Published : 2014.02.28

Abstract

Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Keywords

References

  1. Korea Energy Economics Institute, Yearbook of Energy Statistics, No33901, 2012, pp. 222-223
  2. Energy Audits of High-Rise Residential Buildings, CMHC, 1996
  3. ISO 9972, Thermal performance of buildings- Determination of air permeability of buildings- Fan pressurization method, 2006
  4. DIN EN13829, Thermal performance of buildings Determination of air permeability of buildings Fan pressurization method, 2001
  5. ASTM E779, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization, 2010
  6. JIS A 2201, Test Method for Performance of building airtightness by Fan Pressurization, 2003
  7. ATTMA TS1, Measuring Air Permeability of Building Envelopes, 2013
  8. CAN/CGBS-149.15, Determination of The Overall Envelope Airtightness of Buildings by the Fan Pressurization Method Using The Building's Air Handling Systems, 1996
  9. Kim, M.H. et al., Feasibility of building envelope air leakage measurement using combination of air handler and blower door, Energy and Buildings Vol. 62, pp. 436-441, 2013 https://doi.org/10.1016/j.enbuild.2013.03.034
  10. S. Sharples. et al., Airtightness testing and Air flow modeling of a three-unit multifamily building, Building Services Engineering Research and Technology 26, pp. 167-172, 2005 https://doi.org/10.1191/0143624405bt117tn
  11. Shin, H. K. et al., Measurement of the Dwelling Unit Airtightness and Evaluation of Energy Standards, Journal of Architectural Institute of Korea, Vol.32, No.1, pp.229-230, 2012
  12. Shin, H. K. et al., A Study on Airtightness of Building Components in The High-rise Building, Journal of Architectural Institute of Korea, Vol. 30, No.1, pp. 33-34, 2010
  13. Jeong, J. W. et al., Case studies of building envelope leakage measurement using an air-handler fan pressurization approach, Building Services Engineering Research and Technology 29, pp.137-155, 2008 https://doi.org/10.1177/0143624407088049
  14. Jo J.H., Measurements of the Dwelling Unit Airtightness in High-rise Residential Buildings, Journal of Architectural Institute of Korea, Vol. 26, No 10, 2010
  15. Jo, J. H., A Case Studyon the Field Measurement and Reduction of the Stack Effect in High-rise Buildings, Journal of Architectural Institute of Korea, Vol. 18, No7, 2002
  16. Han, S.K. et al., Estimation of air-handler fan pressurization test applicability based on the field measurement, Journal of Architectural Institute of Korea, Vol.33, No.1, pp.277-278, 2013
  17. Henri C. Fennell, Jonathan Haehnel, Setting Airtightness Standards, AHURAE Journal, pp.26-30, 2005
  18. Shaw, C. Y. et al., Airtightness and air infiltration of school buildings, ASHRAE Transactions 85, pp.85-95, 1979
  19. Tamura, T.G. et al., Studies on exterior wall air tightness and air infiltration of tall buildings, ASHRAE Transactions 82, pp.179-190, 1976

Cited by

  1. 국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발 vol.11, pp.3, 2020, https://doi.org/10.5804/lhij.2020.11.3.69