References
- Korea Energy Economics Institute, Yearbook of Energy Statistics, No33901, 2012, pp. 222-223
- Energy Audits of High-Rise Residential Buildings, CMHC, 1996
- ISO 9972, Thermal performance of buildings- Determination of air permeability of buildings- Fan pressurization method, 2006
- DIN EN13829, Thermal performance of buildings Determination of air permeability of buildings Fan pressurization method, 2001
- ASTM E779, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization, 2010
- JIS A 2201, Test Method for Performance of building airtightness by Fan Pressurization, 2003
- ATTMA TS1, Measuring Air Permeability of Building Envelopes, 2013
- CAN/CGBS-149.15, Determination of The Overall Envelope Airtightness of Buildings by the Fan Pressurization Method Using The Building's Air Handling Systems, 1996
- Kim, M.H. et al., Feasibility of building envelope air leakage measurement using combination of air handler and blower door, Energy and Buildings Vol. 62, pp. 436-441, 2013 https://doi.org/10.1016/j.enbuild.2013.03.034
- S. Sharples. et al., Airtightness testing and Air flow modeling of a three-unit multifamily building, Building Services Engineering Research and Technology 26, pp. 167-172, 2005 https://doi.org/10.1191/0143624405bt117tn
- Shin, H. K. et al., Measurement of the Dwelling Unit Airtightness and Evaluation of Energy Standards, Journal of Architectural Institute of Korea, Vol.32, No.1, pp.229-230, 2012
- Shin, H. K. et al., A Study on Airtightness of Building Components in The High-rise Building, Journal of Architectural Institute of Korea, Vol. 30, No.1, pp. 33-34, 2010
- Jeong, J. W. et al., Case studies of building envelope leakage measurement using an air-handler fan pressurization approach, Building Services Engineering Research and Technology 29, pp.137-155, 2008 https://doi.org/10.1177/0143624407088049
- Jo J.H., Measurements of the Dwelling Unit Airtightness in High-rise Residential Buildings, Journal of Architectural Institute of Korea, Vol. 26, No 10, 2010
- Jo, J. H., A Case Studyon the Field Measurement and Reduction of the Stack Effect in High-rise Buildings, Journal of Architectural Institute of Korea, Vol. 18, No7, 2002
- Han, S.K. et al., Estimation of air-handler fan pressurization test applicability based on the field measurement, Journal of Architectural Institute of Korea, Vol.33, No.1, pp.277-278, 2013
- Henri C. Fennell, Jonathan Haehnel, Setting Airtightness Standards, AHURAE Journal, pp.26-30, 2005
- Shaw, C. Y. et al., Airtightness and air infiltration of school buildings, ASHRAE Transactions 85, pp.85-95, 1979
- Tamura, T.G. et al., Studies on exterior wall air tightness and air infiltration of tall buildings, ASHRAE Transactions 82, pp.179-190, 1976
Cited by
- 국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발 vol.11, pp.3, 2020, https://doi.org/10.5804/lhij.2020.11.3.69