Fish length dependence of target strength for black rockfish, goldeye rockfish at 70kHz and 120kHz (70kHz 및 120kHz에 있어서 조피볼락, 불볼락에 대한 반사강도의 체장 의존성)

  • Mun, Jae-Ho;Lee, Dae-Jae;Shin, Hyeong-Il;Lee, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.42 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Black rockfish and goldeye rockfish are commercially important fish species due to the increasing demand in Korea. When estimating the abundance of stocks for these species acoustically, it is of crucial importance to know the target strength(TS) to length dependence. In relation to these needs, TS measurement was conducted on black rockfish and goldeye rockfish in an acrylic salt water tank using 70kHz and 120kHz split beam echo sounders. The TS for these two species under the controlled condition was simultaneously measured with the swimming movement by DVR system and analyzed as a function of fish length(L). The results obtained are summarized as follows: The best fit regression of TS on fish length of black rockfish was TS=19.38 Log(L, cm)-70.46 ($r^2=0.71$) at 70kHz and TS=22.39 Log(L, cm)-70.40 ($r^2=0.64$) at 120kHz and in the standard form TS=20 Log(L, cm)-71.29 ($r^2 = 0.70$) at 70kHz and TS=20 Log(L, cm)-66.88 ($r^2=0.57$) at 120kHz. The best fit regression of TS on fish length of goldeye rockfish was TS=17.10 Log(L, cm)-68.28 ($r^2=0.37$) at 70kHz and TS=24.39 Log(L, cm)-73.74 ($r^2=0.59$) at 120kHz and in the standard form TS=20 Log(L, cm)-72.03 ($r^2=0.32$) at 70kHz and TS=20 Log(L, cm)-67.68 ($r^2=0.64$) at 120kHz. An empirical model for fish TS(dB) averaged over the dorsal aspect of 115 fishes of black rockfish and goldeye rockfish and which spans the fish length(L, m) to wavelength($\lambda$, m) ratio between 8 and 30 was derived : TS=34.12 Log(L)-14.12 Log($\lambda$)-23.83, ($r^2=0.90$).

3D Measurement Method Based on Point Cloud and Solid Model for Urban SingleTrees (Point cloud와 solid model을 기반으로 한 단일수목 입체적 정량화기법 연구)

  • Park, Haekyung
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_2
    • /
    • pp.1139-1149
    • /
    • 2017
  • Measuring tree's volume is very important input data of various environmental analysis modeling However, It's difficult to use economical and equipment to measure a fragmented small green space in the city. In addition, Trees are sensitive to seasons, so we need new and easier equipment and quantification methods for measuring trees than lidar for high frequency monitoring. In particular, the tree's size in a city affect management costs, ecosystem services, safety, and so need to be managed and informed on the individual tree-based. In this study, we aim to acquire image data with UAV(Unmanned Aerial Vehicle), which can be operated at low cost and frequently, and quickly and easily quantify a single tree using SfM-MVS(Structure from Motion-Multi View Stereo), and we evaluate the impact of reducing number of images on the point density of point clouds generated from SfM-MVS and the quantification of single trees. Also, We used the Watertight model to estimate the volume of a single tree and to shape it into a 3D structure and compare it with the quantification results of 3 different type of 3D models. The results of the analysis show that UAV, SfM-MVS and solid model can quantify and shape a single tree with low cost and high time resolution easily. This study is only for a single tree, Therefore, in order to apply it to a larger scale, it is necessary to follow up research to develop it, such as convergence with various spatial information data, improvement of quantification technique and flight plan for enlarging green space.

The Job Status of Health Teacher, School Nurse, during Epidemic Outbreak of Influenza H1N1 in School (학교 신종플루 확산기 동안의 초등학교 보건교사의 직무현황)

  • Shin, Sun-Mi;Kim, Hye-Soon;Hong, Min-Soon;Lee, Hee-Woo
    • Journal of the Korean Society of School Health
    • /
    • v.23 no.1
    • /
    • pp.63-70
    • /
    • 2010
  • Purpose: To identify the need to reform in the crisis response of Health Teacher, School Nurse, in elementary school during epidemic outbreak of influenza H1N1. Methods: 139 elementary health teachers, school nurse, in seoul elementary school responded in the questionnaire, and we analysed by using frequency and percent, t-test, and paired t-test. Results: The Job status became 121% more 'during influenza H1N1 (flu) outbreak' than Job status of 'before outbreak'. The proportion of the flu-related duty among their daily workload was up to 77.5%. The administration-related workload of the flu-related duty was 30.8%. and students' health assessment including temperature measurement 18.7%. Furthermore, an impediment of usual daily work due to an increaed flu-related workload was 95.7%, and no alternative plan such as disposition of assistant labor force was 86.1%. Especially, an impediment of health education was 61.0%, so the major concern was the loss of health education. We compared average scores (a five-point Likert scale) of health teachers' work motivation, exhaustion, work relationship and Job management of 'during' with 'before' flu-outbreak. The difference range of 'during' minus 'before' work motivation score was from -0.4 points to -0.9; work exhaustion range from 1.8 to 1.9; the difficulty of relationship between students, school personnel, parents of students, and health teachers from 1.4 points to 1.3 points; and the consideration of changing Job, taking time off from the Job and retirement from 1.4 to 1.6 points. Conclusion: The health teachers had a heavy workload due to flu-outbreak. They also experienced the impediment of usual work implementation. However, there was a shortage of alternative plan such as disposition of an assistant labor force. Under their Job status like this, the health teachers' motivation score was decreased and work exhaustion was increased. Furthermore, they had a lot of relation difficulty with students and school personnel. Therefore, we suggested that in contrast to the usual Job status, there is a need to have a prepared response during school crisis like flu-outbreak such as improved response system in seoul metropolitan education office, simplification or dispersion of administrative work, and temporary call-center for simple inquiries or advices.

Characteristics of Electrospun Ag Nanofibers for Transparent Electrodes (전기방사법으로 제조된 Ag 나노섬유의 투명전극 특성)

  • Hyeon, Jae-Young;Choi, Jung-Mi;Park, Youn-Sun;Kang, Jiehun;Sok, Junghyun
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.3
    • /
    • pp.156-161
    • /
    • 2013
  • We fabricated transparent conductive electrodes with silver (Ag) nanofibers by electrospinning process. Ag nanofibers have high aspect ratio and fused junctions which result in low sheet resistance. Electrospinning is a fast and efficient process to fabricate continuous one-dimensional (1D) nanofibers. Ag/polymer ink were prepared in polymer matrix solution by a sol-gel method. Then, Ag/polymer nanofibers precursors are heated at $200{\sim}500^{\circ}C$ in air for 2 h to eliminate partially the polymers. The topographical features of the Ag nanofibers were characterized by FE-SEM, and the electrical property was analyzed through I-V measurement system. Finally, optical property was measured using UV/VIS spectroscopy. The transparent conductive electrodes with Ag nanofibers exhibited a sheet resistance (Rs) of $250{\Omega}/sq$ at a transparency (T) of 83%. Transparent conductive films, contain the Ag nanofibers as conductive materials, have good electrical, optical, and mechanical properties. Therefore, it is expected to be useful for the application of flexible display in the future.

A study on the applicability of power usage method for the analysis of river water intake (하천수 취수량 분석을 위한 전력량법의 적용성 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, JunHo;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.12
    • /
    • pp.975-984
    • /
    • 2019
  • As an essential prerequisite for systematic and integrated management of river water, it is necessary to secure the basic data such as discharge supplied to the river and released from the river. Under the current permit system for river water use, 59.1% of licensed facilities were found to have no discharge meters in 2017, especially for agricultural water, which makes it difficult to secure reliable data as a large portion of the reports are voluntarily reported by users. In this study, the indirect discharge measurement method of calculating the discharge through the power usage of the pumping station was applied to secure reliable discharge data. In particular, focusing on the fact that the discharge calculated by the power usage method differed with the actual discharge according to the level of the river, the study was conducted on improving the power usage method reflecting the river water level and improving the accuracy of discharge data. Analysis of the discharge calculated using the power usage method considering river water level using the correlation analysis method such as regression analysis, percent difference, root mean square error etc. confirmed that the results are not high compared to the conventional power usage method, but are slightly more approximated to the actual discharge. Therefore, although reliable discharge data can be obtained from the existing power usage method, it is expected that more accurate data on intaking water of river water can be obtained if the improved power usage method is used at points where the variation in the water level of the river is large.

Assessment of the Usability of Digital TV Remote Control Pointing Methods (Digital TV 리모컨의 포인팅 방식에 대한 사용성 평가)

  • Cheong, Kyeong-Kyun;Kim, In-Soo;Park, Sung-Kwon;Park, Yong-Jin
    • Journal of Broadcast Engineering
    • /
    • v.16 no.4
    • /
    • pp.657-668
    • /
    • 2011
  • Along with the development of communication technology, DTV is gradually evolving into media that provide diverse services and information. This study is related with remote controls that control DTV interfaces and assessed the usability of remote pointing device. To this end, pointing devices using three different interaction methods that have been attempted recently by the industry were selected to conduct empirical experiments. The usability assessment was conducted centering on the existing directional task on straight tracks presented in ISO 9241-Part 9 and the steering tunnel task on curved tracks proposed in this study. The measurement variables included movement time, accuracy, throughput, subjective satisfaction and user behaviors. Based on the results of the assessment, in the case of movements on straight tracks, the GyroPoint method showed better implementing time but lower accuracy compared to the Hall Mouse and OFN methods while in the case of assessment on curved tracks, all of the GyroPoint method, Hall Mouse and OFN methods showed excellent results on both implementing time and accuracy. Besides, differences in efficiency and subjective satisfaction were shown among individual pointing devices. Based on these results, it is considered that individual pointing methods have different advantageous and disadvantageous characteristics. In this study, the usability of remote control pointing methods was assessed and diagnosed reflecting environments where DTVs are used through assessments considering the aspect of straight tracks along with curved tracks. Among others, this study is considered to be meaningful in that it provides assessment criteria and basic data for the development of remote controls suitable for the evolving DTV environments.

A Study on Construction of Optimal Wireless Sensor System for Enhancing Organization Security Level on Industry Convergence Environment (산업융합환경에서 조직의 보안성 향상을 위한 센싱시스템 구축 연구)

  • Na, Onechul;Lee, Hyojik;Sung, Soyoung;Chang, Hangbae
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.4
    • /
    • pp.139-146
    • /
    • 2015
  • WSN has been utilized in various directions from basic infrastructure of environment composition to business models including corporate inventory, production and distribution management. However, as energy organizations' private information, which should be protected safely, has been integrated with ICT such as WSN to be informatization, it is placed at potential risk of leaking out with ease. Accordingly, it is time to need secure sensor node deployment strategies for stable enterprise business. Establishment of fragmentary security enhancement strategies without considering energy organizations' security status has a great effect on energy organizations' business sustainability in the event of a security accident. However, most of the existing security level evaluation models for diagnosing energy organizations' security use technology-centered measurement methods, and there are very insufficient studies on managerial and environmental factors. Therefore, this study would like to diagnose energy organizations' security and to look into how to accordingly establish strategies for planning secure sensor node deployment strategies.

A Study of Effect that Tourist Hotel Employee's Service Quality on Customer Satisfaction, Trust and Commitment (관광호텔종사원의 서비스 품질이 고객만족, 신뢰.몰입에 미치는 영향)

  • 이지영;하종명
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.16 no.2
    • /
    • pp.33-56
    • /
    • 2005
  • The purpose of this study is to understand the critical role of customers' perceived service quality. in relationship marketing. This paper examined the relationships of service quality with customer satisfaction, and investigated the effects of trust and commitment. Data were collected from 242 people at hotel located in Taegu city. LISREL provided satisfactory model-fits in measurement model and structural equation model. The empirical results indicated that first, service quality takes strong effect on customer satisfaction and trust but not on commitment. Second, trust and commitment are importantly influenced by customer satisfaction. Third, service quality was found to indirectly contribute to trust and commitment. Finally, customer satisfaction is effective mediators linking service quality to trust and commitment. The effects of these variables on trust and commitment, which are based on social exchange theory, were empirically confirmed.

  • PDF

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

Differential Excretion of Urinary Eosinophil Protein X after Methacholine Challenge Test in Children with Asthma (천식 환아에서 요중 Eosinophil Protein X의 메타콜린 기관지 유발 시험 전·후의 변화)

  • Shin, Su-A;Oh, Jae-Won;Lee, Ha-Baik
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.495-499
    • /
    • 2003
  • Purpose : Eosinophil is one of the important inflammatory cell involved in the airway inflammation in childhood asthma. It has been demonstrated that markers of eosinophil activation, including eosinophil cationic protein or eosinophil protein X(EPX), are increased in childhood asthma. Furthermore, they are related to disease activity and are assumed to be helpful in monitoring the treatment effect as urinary EPX(U-EPX) can be obtained easily and in a noninvasive way in children of all ages. Methods : Twenty-five children(22 male and three female) aged $11.87{\pm}3.82$ years with stable asthma were challenged with methacholine and urine was collected from each child during the following periods; before methacholine challenge test(MCT); 0-3 hr after the end of MCT; 4-7 hr after the end of MCT; and 8-24 hr after the end of MCT. Bronchial reactivity was determined by using Dosimeter( Jeager, Germany) with serially diluted methacholine from 0.05 to 25.0 mg. The $FEV_1$ less than 80% of baseline value were classified into positive MCT. U-EPX was measured with a sensitive and specific radioimmunoassay(Pharmacia & Upjohn AB, Uppsala, Sweden). Results were expressed as ${\mu}gEPX/mmol$ creatinine. Results : An early airway response after MCT was associated with an increase of U-EPX excretion for 0-3 hr after methacholine inhalation in comparison with beseline values. Most subjects showed a small increase in U-EPX excretion during late asthmatic response for 4-7 hr, which then decreased to normal level in 8-24 hr. Also, a tendency for a higher increase of U-EPX was associated with a lower threshold of methacholine challenge and a longer duration of asthma. Conclusion : Measurement of EPX in urine is a noninvasive and easy method to assess the severity of airway inflammation in asthmatic children. It may be a helpful index of the events underlying the airway inflammatory responses during nonspecific bronchial challenge, and in monitoring asthma management.