• 제목/요약/키워드: Measurement locations

검색결과 582건 처리시간 0.031초

궤환 가진기를 이용한 모델 개선법 (Model updating using the feedback exciter)

  • 정훈상;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1150-1155
    • /
    • 2001
  • The updating of the FE model to match it with the experimental results needs the modal information. There are two causes where this methodology is ill-equip to deal with; under-determined and ill-conditioning problem. In this research, the feedback exciter which uses the summation of the white noise and the signals from the measurement sensors multiplied with feedback gains is proposed. The new energy path generated by the feedback exciter changes the modal characteristics of the system and this additional modal information can solve the under-determined problem in the model updating. Through the proper selection of the exciter and sensor locations and the feedback gain, the eigenvalue sensitivity of the updating parameters which cause the ill-conditioning of the sensitivity matrix can be modified. This methodology does not require any additional equipments, makes the acquirement of the additional modal information easy and is robust to the measurement noise.

  • PDF

대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가 (Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement)

  • 전의찬
    • 환경영향평가
    • /
    • 제5권1호
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

파형강판을 이용한 지중-강판 교량의 시공현장계측 (Field Measurements of Soil-Steel Bridge)

  • 이종구;김경석;이종화;조성민;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.331-338
    • /
    • 2001
  • The soil-steel bridges which were introduced in Korea recently are widely used instead of underpasses of highway or small bridges. This bridge is a kind of flexible buried conduit which sustain the applied load by the interaction with the backfill soil. The 6.25m din. round soil-steel bridge was instrumented so as to investigate the behavior of load sustenance, The axial forces and moments at the 7 locations around the metallic shell were calculated from the measurement of strains during backfilling. The maximum axial force and moment were compared with those of various design predictions. Finally, the stability of bridge was evaluated.

  • PDF

FEM Analysis of Plasticity-induced Error on Measurement of Welding Residual Stress by the Contour Method

  • Shin, Shang-Hyon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권10호
    • /
    • pp.1885-1890
    • /
    • 2005
  • The contour method relies on deformations that occur when a residually stressed component is cut along a plane. The method is based on the elastic superposition principle. When plasticity is involved in the relaxation process, stress error in the resulting measurement of residual stress would be caused. During the cutting the specimen is constrained at a location along the cut so that deformations are restrained as much as possible during cutting. With proper selection of the constraining location the plasticity effect can also be minimized. Typical patterns of longitudinal welding residual stress state were taken to assess the plasticity effect along with constraining locations.

차음성능시험에서 시편설치위치에 대한 실험적 고찰 (Investigation for effect of the specimen location on sound transmission loss measurement)

  • 김상렬;강현주;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1234-1237
    • /
    • 2002
  • When measuring sound transmission loss (STL) in a laboratory, the specimen location in test aperture affects considerably the measuring accuracy through the influence of so-called “tunneling effect” In this paper, for a single panel and a double panel with air cavity, experimental STL evaluations on various specimen locations on test aperture were carried out to explain the phenomenon. It is shown that the difference of STL is more than 2dB especially at the low frequency region and the case of the center-located panel yielded the lower STL than that of flushing with the end of tunnel, which confirms that the tunneling effect plays an important role in STL measurement.

  • PDF

해상용 대형 가스터빈의 소음 저감을 위한 흡음형 소음기의 설계 및 성능 측정 (Design and Measurement of Dissipative Silencers for Noise Reduction of Large Maritime Gas Turbine Engines)

  • 백성현;이강희;권대훈;이일재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.367-371
    • /
    • 2014
  • Based on ISO 7235, an experimental setup to measure the acoustic performance of splitter type dissipative silencers are fabricated. The length of each duct, sound source, microphone locations, modal filter, and anechoic termination are considered in the design of this setup. The modal filter is a particularly important factor because it affects the limit of measurement, which is also determined by the amount of flanking transmission of sound generated by the sound source to microphones. The effects of absorptive materials, media which covers the materials, and the number of splitters on the noise reduction of the sample silencers are experimentally investigated. The insertions loss of silencers with media and higher number of splitters increases, especially at higher frequencies.

  • PDF

고속도로 교통소음 예측-전달감쇠 산정 (Prediction of Highway Traffic Noise-calculation of Sound Attenuation during Propagation)

  • 조대승;김진형;최태묵;오정한;김성훈
    • 한국소음진동공학회논문집
    • /
    • 제12권3호
    • /
    • pp.236-242
    • /
    • 2002
  • This paper presents some advanced and supplemental methods to enhance the accuracy In case of calculating geometric divergence attenuation, attenuation by multiple screening structures, ground attenuation at unflat surfaces of sound during propagation outdoors by the methods specified in ISO 9613-2. Moreover, a calculation method for considering short-term wind effect, specified in ASJ Model-1998, is also introduced. To verity the accuracy of adopted methods, we have carried out highway traffic noise prediction and measurement at tile twelve locations appearing representative road shapes and structures, such as flat, retained cut, elevated, barrier-constructed roads. From the results, we have confirmed the predicted results show good correspondence with the measured at direct, diffracted and reflected sound fields within 30 m from the center of near side lane.

철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 수치연구 (Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires)

  • 장원철;김동운;유홍선;이성혁
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2130-2138
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading characteristics in railway tunnels with the rescue stations. Experiments were carried out for n-heptane pool fires with a square length 4 cm at different fire locations, and the heat release rates (HRR) were obtained by the measurement of burning rates. In addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

  • PDF

3차원 거리 측정 장치를 이용한 물체 인식 (Object Recognition using 3D Depth Measurement System.)

  • 김성찬;고수홍;김형석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.941-942
    • /
    • 2006
  • A depth measurement system to recognize 3D shape of objects using single camera, line laser and a rotating mirror has been investigated. The camera and the light source are fixed, facing the rotating mirror. The laser light is reflected by the mirror and projected to the scene objects whose locations are to be determined. The camera detects the laser light location on object surfaces through the same mirror. The scan over the area to be measured is done by mirror rotation. The Segmentation process of object recognition is performed using the depth data of restored 3D data. The Object recognition domain can be reduced by separating area of interest objects from complex background.

  • PDF

직류전기철도에서의 실시간 누설전류 계측기법에 관한 조사분석 (Investigation of the real time stray current monitoring techniques on the DC railway system)

  • 정호성;한문섭;박영;김형철;김진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.201-203
    • /
    • 2009
  • This paper presents the real time stray current monitoring techniques on the DC railway system. These techniques are two types. The first one is the rail potential measurement technique between running rail and earthing mats on the important locations such as substation, station, and so on. And the second one is measurement technique of stray current through substation earthing mats and from collection mats, and continuous monitoring of return currents through the running rails. We need to apply these techniques on DC railway system to monitor stray current periodically and maintain the system properly.

  • PDF